Plan Review Details - Permit 18081455
Plan Review Stops For Permit 18081455 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2019-04-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-08 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-08 |
Time |
08:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-02-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-02-08 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-02-08 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-12-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-12-12 |
Time |
18:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-12-12 |
Time |
17:54 |
Sent To |
|
|
Notes |
2018-12-12 18:03:29 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 1- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | FBC R 401.3 (DRAINAGE) | | FBC 107.2.5 (SITE PLAN) | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | SEC. R401.3 FBC_RESIDENTIAL: | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN | | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE | | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE | | FIRST 10 FEET (3048 MM). | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE | | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 | | PERCENT AWAY FROM THE BUILDING. | | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED ON A BOUNDARY LINE SURVEY. IN THE CASE OF | | DEMOLITION, THE SITE PLAN SHALL SHOW CONSTRUCTION TO BE | | DEMOLISHED AND THE LOCATION AND SIZE OF EXISTING | | STRUCTURES AND CONSTRUCTION THAT ARE TO REMAIN ON THE | | SITE OR PLOT. THE BUILDING OFFICIAL IS AUTHORIZED TO | | WAIVE OR MODIFY THE REQUIREMENT FOR A SITE PLAN WHEN | | THE | | APPLICATION FOR PERMIT IS FOR ALTERATION OR REPAIR OR | | WHEN OTHERWISE WARRANTED. | | | | SEC. 110.9 CITY AMENDMENTS: IMPACT OF CONSTRUCTION. ALL | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | GRANTED BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS | | OR CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | OWNER. THIS INCLUDES, BUT IS NOT LIMITED TO, THE | | CONTROL OF DUST, NOISE, WATER OR DRAINAGE RUN-OFFS, | | DEBRIS, AND THE STORAGE OF CONSTRUCTION MATERIALS. NEW | | CONSTRUCTION ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL | | HISTORIC SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT | | PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN | | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE | | POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. | | ACCORDINGLY, DEVELOPERS, CONTRACTORS AND OWNERS OF ALL | | NEW RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, | | POOLS, PATIOS, DRIVEWAYS, DECKS | | OR SIMILAR ITEMS, ON EXISTING PROPERTIES RESULTING IN A | | SIGNIFICANT DECREASE OF PERMEABLE LAND AREA ON ANY | | PARCEL OR HAS ALTERED THE DRAINAGE FLOW ON THE | | DEVELOPED PROPERTY SHALL, AS A PERMIT CONDITION, | | PROVIDE A PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | COMPLETION OF THE IMPROVEMENT, A CERTIFICATION FROM A | | LICENSED PROFESSIONAL SHALL BE SUBMITTED TO THE | | INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE FINAL | | INSPECTION. | | | | RESPONSE: | | RESPONSE LETTER SAYS "OWNERS RESPONSIBILITY". | | INFORMATION SUBMITTED ON SURVEY DOESN'T COMPLY. IT'S | | NOT CLEAR HOW TO PREVENT WATER TO DRAIN TO ADJACENT | | PROPERTY . SEE TYPICAL BERM/SWALE DETAIL AND CLARIFY | | HOW TO KEEP WATER WITHIN THE PROPERTY WHEN THE FINISHED | | GRADE IS LOWER ON THE ADJACENT PROPERTY. SURVEYOR IS | | ALSO STATING THAT IS NOT LICENSED TO PERFORM | | ENGINEERING. PROVIDE PROFESSIONALLY PREPARED DRAINAGE | | PLAN AS REQUIRED BY SEC. 110.9 CITY AMENDMENTS. SEE | | PARAGRAPH ABOVE. | | | | 2- IMPACT FEES - PAPER SUBMITTAL | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACT-FEES/FORMS/QUESTIONNAIRE.PDF | | | | ORIGINAL COMMENT; | | 3- PROVIDE SOIL TEST REPORT. SEE ENGINEER'S GENERAL | | FOUNDATION NOTES. SEC. R401.4 FBC-RESIDENTIAL. | | | | RESPONSE: | | RESPONSE LETTER STATES "OWNERS RESPONSIBILITY" BUT IT | | WAS NOT ADDRESSED. | | | | | | 4- SHEET S.4: | | A) OK | | B) OK | | C) OK | | | | 5- OK. | | | | 6- OK. | | | | 7- OK | | | | 8- OK. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-01 |
Time |
19:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-01 |
Time |
13:55 |
Sent To |
|
|
Notes |
2018-10-01 19:07:32 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | FBC R 401.3 (DRAINAGE) | | FBC 107.2.5 (SITE PLAN) | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | SEC. R401.3 FBC_RESIDENTIAL: | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN | | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE | | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE | | FIRST 10 FEET (3048 MM). | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE | | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 | | PERCENT AWAY FROM THE BUILDING. | | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED ON A BOUNDARY LINE SURVEY. IN THE CASE OF | | DEMOLITION, THE SITE PLAN SHALL SHOW CONSTRUCTION TO BE | | DEMOLISHED AND THE LOCATION AND SIZE OF EXISTING | | STRUCTURES AND CONSTRUCTION THAT ARE TO REMAIN ON THE | | SITE OR PLOT. THE BUILDING OFFICIAL IS AUTHORIZED TO | | WAIVE OR MODIFY THE REQUIREMENT FOR A SITE PLAN WHEN | | THE | | APPLICATION FOR PERMIT IS FOR ALTERATION OR REPAIR OR | | WHEN OTHERWISE WARRANTED. | | | | SEC. 110.9 CITY AMENDMENTS: IMPACT OF CONSTRUCTION. ALL | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | GRANTED BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS | | OR CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | OWNER. THIS INCLUDES, BUT IS NOT LIMITED TO, THE | | CONTROL OF DUST, NOISE, WATER OR DRAINAGE RUN-OFFS, | | DEBRIS, AND THE STORAGE OF CONSTRUCTION MATERIALS. NEW | | CONSTRUCTION ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL | | HISTORIC SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT | | PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN | | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE | | POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. | | ACCORDINGLY, DEVELOPERS, CONTRACTORS AND OWNERS OF ALL | | NEW RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, | | POOLS, PATIOS, DRIVEWAYS, DECKS | | OR SIMILAR ITEMS, ON EXISTING PROPERTIES RESULTING IN A | | SIGNIFICANT DECREASE OF PERMEABLE LAND AREA ON ANY | | PARCEL OR HAS ALTERED THE DRAINAGE FLOW ON THE | | DEVELOPED PROPERTY SHALL, AS A PERMIT CONDITION, | | PROVIDE A PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | COMPLETION OF THE IMPROVEMENT, A CERTIFICATION FROM A | | LICENSED PROFESSIONAL SHALL BE SUBMITTED TO THE | | INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE FINAL | | INSPECTION. | | | | 2- IMPACT FEES - PAPER SUBMITTALS | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | 3- PROVIDE SOIL TEST REPORT. SEE ENGINEER'S GENERAL | | FOUNDATION NOTES. SEC. R401.4 FBC-RESIDENTIAL. | | | | 4- SHEET S.4: | | A) ENGINEER TO CLARIFY/REVISE CONCRETE SLAB STRENGTH. | | SPECIFICATIONS SHOWN ON THE GENERAL FOUNDATION NOTES | | AND SPECIFICATIONS SHOWN ON THE FOUNDATION PLAN DON'T | | MATCH. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | B) ENGINEER TO CLARIFY/REVISE SOIL BEARING CAPACITY. | | SPECIFICATIONS SHOWN ON THE GENERAL FOUNDATION NOTES | | AND SPECIFICATIONS SHOWN ON THE FOUNDATION PLAN DON'T | | MATCH. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | C) REVISE ROOF SHEATHING FASTENER SPACING FOR ZONES 1 | | AND 2 IN THE COMPONENT AND CLADDING PRESSURE ZONES | | TABLE. ACCORDING TO SEC. R803.2.3.1 FBC-RESIDENTIAL THE | | SPACING SHALL BE 6" O.C. NOT 12". | | | | 5- SPECIFY CARBON MONOXIDE ALARMS BY ALL THE BEDROOMS | | AS REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL. | | | | 6- FLOOR PLAN ON SHEET S.2 IS MISSING INSULATION | | BETWEEN THE GARAGE AND THE MIDDLE BEDROOM. SEE ENERGY | | CALCULATIONS FOR REQUIRED R-VALUE. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 7- SPECIFY THE ATTIC LIVE LOAD AS REQUIRED BY TABLE | | R301.5 FBC-RESIDENTIAL. | | NOTE: SEE FOOTNOTES B AND G OF TABLE R301.5 ADDITIONAL | | LIVE LOAD MAY BE REQUIRED BASED ON THE ATTIC SPACE | | SHOWN ON PLANS. | | | | 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. VALUATION WAS UPDATED TO $174492. THE | | PERMIT FEE BALANCE IS $3,361.92. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-02-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-02-13 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-02-13 |
Time |
14:50 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-11-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-29 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-29 |
Time |
15:52 |
Sent To |
|
|
Notes |
2018-11-29 16:40:47 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. CORRECTED. | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | NEC 110.9, 110.10; FBC RE E3603.3 (THE AMOUNT OF FAULT | | CURRENT PROVIDED STATES THAT THERE IS 21110 AMPERES | | AVAILABLE, BUT THE RATING OF THE METER MAIN COMBO IS | | ONLY 10000. PROVIDE CORRECTION.) | | 3. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902 (NOTE STATES THAT AFCI | | PROTECTION WILL BE PROVIDED AS INDICATED. HOWEVER, THE | | PANEL SCHEDULE DOES NOT INDICATE ALL THE AREAS THAT ARE | | REQUIRED TO HAVE AFCI PROTECTION. PROVIDE CORRECTION BY | | EITHER REMOVING THIS FROM PANEL SCHEDULE DESCRIPTIONS | | AND RELY ON NOTE, OR LISTING ALL AREAS REQUIRED IN | | PANEL SCHEDULE. AS IT CURRENTLY IS WRITTEN, IT APPEARS | | THAT ONLY THE ITEMS SHOWN AS AFCI IN PANEL SCHEDULE ARE | | REQUIRED TO BE AFCI, WHICH IS NOT CORRECT.) | | 4. CORRECTED. | | 5. CORRECTED. | | 6. CORRECTED. | | 7. CORRECTED. | | 8. CORRECTED. | | 9. CORRECTED. | | 10. CORRECTED. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-09-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-24 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-24 |
Time |
13:09 |
Sent To |
|
|
Notes |
2018-09-24 16:32:02 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ACCURATE LOAD CALCULATION. EACH SMALL | | APPLIANCE CIRCUIT SHOULD BE CALCULATED AT 1500 VA, | | PANEL SHOWS 3 CIRCUITS. DEMAND FACTORS SHOULD NOT BE | | APPLIED TO AHU/AC LOAD. PROVIDE CORRECTIONS. NEC 220; | | FBC RE E3602.2 | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | NEC 110.9, 110.10; FBC RE E3603.3 | | 3. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902 | | 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 | | 5. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | OUTLETS IN GARAGE INCLUDING GARAGE DOOR OPENER. PROVIDE | | CORRECTION. NEC 210.8; FBC RE E3902.2 | | 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | 210.8(D); FBC RE E3902.10 | | 7. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | 8. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC RE R315.1 | | 9. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | R314.3(4), NFPA 72:29.8.3.4 | | 10. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. OUTLET | | IN FRONT IS MISSING. PROVIDE CORRECTION. NEC | | 210.52(E)(1) FBC RE E3901.7 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-04-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-08 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-03-29 |
Time |
12:57 |
Sent To |
|
|
Notes |
2019-04-01 12:47:56 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-02-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-02-13 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-01-25 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-01-03 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-01-03 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-11-09 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-04 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-29 |
Time |
14:25 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
5 |
Status |
P |
Date |
2019-04-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-09 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-09 |
Time |
11:37 |
Sent To |
|
|
Notes |
2019-04-09 11:47:03 | $9,585.84 PAID. MU-2019-006310- |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2019-04-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-08 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-08 |
Time |
08:42 |
Sent To |
|
|
Notes |
2019-04-08 09:34:32 | NEED COPY OF PAID RECEIPT. JG. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2019-02-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-02-08 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-02-08 |
Time |
12:44 |
Sent To |
|
|
Notes |
2019-02-08 12:44:41 | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2018-12-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-12-12 |
Time |
18:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-12-12 |
Time |
18:48 |
Sent To |
|
|
Notes |
2018-12-12 18:48:38 | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-10-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-01 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-01 |
Time |
15:36 |
Sent To |
|
|
Notes |
2018-10-01 15:36:20 | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-11-16 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-11-16 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-11-16 |
Time |
13:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-04 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-04 |
Time |
07:52 |
Sent To |
|
|
Notes |
2018-10-01 17:27:23 | NEW SINGLE FAMILY RESIDENCE (R3) MECHANICAL REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- REVISE THE BALANCED RETURN AIR TRANSFER DUCT SIZE | | SPECIFIED FOR SECONDARY BEDROOMS 2 AND 3. NEED AT LEAST | | 9" DUCT FOR BEDROOM WITH 7" SUPPLY DUCT AND AT LEAST | | 10" DUCT FOR BEDROOM WITH 8" SUPPLY DUCT AS REQUIRED BY | | SEC. M1602.3 FBC-RESIDENTIAL. | | | | 2- PROVIDE THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE A/C DESIGN AS REQUIRED BY SEC. | | 107.2.1 CITY AMENDMENTS. | | | | 3- REVISE THE HVAC LOAD CALCULATIONS: | | A) THE FRONT DOOR OF THIS HOUSE DOESN'T FACE SOUTHEAST. | | ACCORDING TO SEC. R403.7.1 FBC-ENERGY CONSERVATION | | CALCULATIONS NEED TO BE DONE BASED ON THE ACTUAL | | ORIENTATION OF THE BUILDING. | | | | B) CALCULATIONS ARE PREPARED BY GOARCH ENGINEERING, | | INC. THE ENGINEER NEEDS TO SIGN AND SEAL CALCULATIONS | | AS REQUIRED BY SEC. 61G15-23.001 FAC AND CHAPTER 471 | | F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. | | | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-12-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-26 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-26 |
Time |
12:27 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-09-27 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-09-27 |
Time |
10:40 |
Sent To |
|
|
Notes |
2018-09-27 10:41:42 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW: | | PLUMBING COMMENTS: DENIED | | | | 1. PROVIDE NOTE STATING "WATER HAMMER ARRESTOR TO BE | | INSTALLED IN ACCORDANCE WITH FBC RES P2903.5" | | 2. PROVIDE NOTE AT SHOWER STATING "SHOWER CONTROL | | VALVE(S) SHALL BE PRESSURE BALANCED PB,THERMOSTATIC | | MIXING (TM) OR COMBINATION PB/TM VALVE TYPES WITH HIGH | | TEMPERATURE LIMITING STOP." FBC RES P2708.4 | | 3. THERMAL EXPANSION DEVICE REQUIRED ON COLD WATER | | SUPPLY TO WATER HEATER. A MEANS FOR CONTROLLING | | INCREASED PRESSURE CAUSED BY THERMAL EXPANSION SHALL BE | | INSTALLED WHERE REQUIRED IN ACCORDANCE WITH SECTIONS | | FBC RES P2903.4.2. | | 4. PROVIDE NOTE STATING "A WATER HEATER PAN AND DRAIN | | IS TO BE INSTALLED IN ACCORDANCE WITH FBC RES P2608.6, | | P2801.6.1 & P2801.6.2" | | 5. PER P3108.1, THE CLOTHES WASHER DRAIN MAY NOT | | DISCHARGE THROUGH THE BATH 2 BATHROOM GROUP. CONNECT | | WASHER DRAIN DOWNSTREAM OF GROUP; TUB DRAIN TO CONNECT | | WET VENT OR IT IS TO BE REVENTED. | | 6. PER P3108.1, THE KITCHEN SINK DRAIN MAY NOT | | DISCHARGE THROUGH THE MASTER BATH BATHROOM GROUP. | | CONNECT SINK DRAIN DOWNSTREAM OF GROUP; CONNECT | | LAVATORY DRAIN TO TUB DRAIN TO COMPLETE WET VENTED | | GROUP. ELIMINATE 2" VENT UPSTEAM OF WATER CLOSET. | | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-04 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-04 |
Time |
07:52 |
Sent To |
|
|
Notes |
2018-10-04 08:00:08 | SHINGLES FL10674-R13. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-04-03 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2019-04-03 |
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2019-02-06 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-02-06 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2019-02-06 |
Time |
|
Sent To |
|
|
Notes |
2019-02-06 10:11:26 | ******ZONING REVIEW FAILED******** | | | | REPEAT COMMENT: PROVIDE LANDSCAPING. | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. | | | | SHOWING THE FOLLOWING: | | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | GROSS LOT SQUARE FOOTAGE MINUS | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2019-01-03 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-01-03 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2019-01-03 |
Time |
|
Sent To |
|
|
Notes |
2019-01-03 11:50:16 | ******ZONING REVIEW FAILED******** | | | | REPEAT COMMENT: PROVIDE LANDSCAPING. | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. | | | | SHOWING THE FOLLOWING: | | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | GROSS LOT SQUARE FOOTAGE MINUS | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-09-21 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2018-09-21 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
awooten |
Date |
2018-09-21 |
Time |
15:58 |
Sent To |
|
|
Notes |
2018-09-21 15:58:12 | **********************************ZONING REVIEW | | FAILED************************** | | | | PROVIDE THE REAR SETBACKS ON THE SURVEY. | | | | DIMENSION MECHANICAL EQUIPMENT SETBACKS (A/C) | | MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN FOUR FEET INTO A SETBACK. | | | | PROVIDE LANDSCAPING. | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. | | | | SHOWING THE FOLLOWING: | | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | GROSS LOT SQUARE FOOTAGE MINUS | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy