Plan Review Stops For Permit 18081393 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-19 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-19 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-04 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-03 |
Time |
07:17 |
Sent To |
|
|
Notes |
2018-10-04 09:45:15 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. LIFE SAFETY PLAN LS-1W SUBMITTED FOR REVIEW DOES NOT | | INDICATE LOCATION OF PROPOSED CONNECTION BRIDGE. | | 2. PROVIDE FLOOR PLAN WITH ELEVATIONS IDENTIFYING | | LOCATION OF PROPOSED CONNECTION BRIDGE. | | 3. UPDATED UL ASSEMBLY SPECIFIES FIRE CAULKING BY 3M | | COMPANY, TYPES FB 1000 NS, FB 1003 SL, FB 2000 AND FB | | 2000 PLUS. ORIGINAL PERMITTED DOCUMENTS SPECIFIES FIRE | | CAULKING TO BE ONE SOURCED, SPECIFICALLY HILTI PRODUCTS | | FS ONE. PLEASE CLARIFY. | | 4. DETAIL FOR CONNECTING BRIDGE SUBMITTED FOR REVIEW | | INDICATES BRIDGE WILL BE SITE BUILT. | | WELDED OR BOLTED CONNECTIONS | | THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | STANDARDS AT TIME OF INSPECTION. | | 2017 FBC-B 2204.1 WELDING | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-10-17 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-10-17 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-10-17 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-09-11 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-09-11 |
Time |
14:44 |
Sent To |
|
|
Notes |
2018-09-11 14:54:19 | PERMIT # 18081393 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | FAILED COMMENTS: | | | | 1) IT'S UNCLEAR EXACTLY WHAT AND WHERE THE CHANGES TO | | BE CONSIDERED ARE. SCOPE STATES THAT FIRE EXTINGUISHER | | LOCATIONS ARE BEING CHANGED, HOWEVER THE PLANS | | SUBMITTED DO NOT INDICATE EXISTING LOCATION NOR | | PROPOSED LOCATIONS. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-11-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-19 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-09 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-04 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-09-04 |
Time |
09:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-10-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-10-25 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-10-25 |
Time |
09:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-09-25 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-09-25 |
Time |
16:55 |
Sent To |
|
|
Notes |
2018-09-25 17:00:37 | 1ST REVIEW FBC-2014 MECHANICAL | | REVISION #18081393 | | MASTER #15120536 | | 9/25/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEAE REVISE ALL MECHANICAL AND/OR PLUMBING SHEETS | | INVOLVED IN THIS REVISION FOR THE AIR AND OIL PIPE | | BRIDGE SUPPORTS, AND THE PIPE PENETRATIONS OF THE | | FIRE-RATED WALL. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-11-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-11-06 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-11-06 |
Time |
09:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-19 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-19 |
Time |
09:28 |
Sent To |
|
|
Notes |
2018-11-06 10:04:31 | 11/6/18 PLUMB SHT DIG SIG OK/GPJ |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-04 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-03 |
Time |
07:17 |
Sent To |
|
|
Notes |
2018-10-04 09:32:23 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DIGITAL SIGNATURES/SEALS ARE IN ACCORDANCE WITH FS | | 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE NEXT | | REVIEW CYCLE REQUIRE REVIEW. |
|
|