2018-11-15 18:52:13PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 REVISION IS DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ENGINEER'S SEAL IS A PHOTOCOPY. THE RAS 117
 CALCULATIONS ARE REQUIRED TO HAVE THE FLORIDA
 ENGINEER'S SEAL AND ORIGINAL HANDWRITTEN SIGNATURE,
 COPIES OR OTHER FACSIMILES ARE NOT ACCEPTABLE. FAC
 61G15 - 23.002 DIGITAL SIGNATURES ARE ONLY ACCEPTABLE
 FOR ELECTRONICALLY TRANSMITTED PLANS AND DOCUMENTS.
  
 2) PAGE 1 OF THE RAS 117 CALCULATIONS UNDER DECK SYSTEM
 TYPE, FASTENING OPTION #4 FROM THE NOA IS SPECIFIED.
 THIS SHOULD BE OPTION #5 SINCE THAT IS THE ONLY ONE
 THAT HAS A -60 PSF. FBC 107.2.1
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-08-30 Cont ID  
Sent By rmcdouga Date 2018-08-30 Time 07:11 Rev Time 0.00
Received By rmcdouga Date 2018-08-30 Time 06:44 Sent To I
Notes
2018-08-30 07:11:55PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 REVISION IS DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PRODUCT APPROVAL THAT WAS SUBMITTED, NOA NO.
 15-1020.01, HAS FASTENING OPTION #3 WITH A MAXIMUM
 DESIGN PRESSURE OF -52.2 PSF FOR A NON-INSULATED WOOD
 DECK SPECIFIED ON PAGE 51 OF 67. THE SIGNED AND SEALED
 RAS 117 CALCULATIONS THAT WERE SUBMITTED ARE SPECIFIC
 TO THIS ASSEMBLY. IN ORDER TO ADD INSULATION TO THIS
 PROJECT, YOU ARE REQUIRED TO SUBMIT THE PRODUCT
 APPROVALS FOR A ROOFING SYSTEM WITH AN INSULATED DECK
 AND SPECIFY THE FASTENING OPTION THAT WILL BE USED. TWO
 SETS OF SIGNED AND SEALED RAS117 CALCULATIONS FOR THE
 SELECTED ASSEMBLY WILL BE REQUIRED IF THE DESIGN
 PRESSURES ARE NOT ADEQUATE FOR ALL ROOF ZONES.
  
 2) THE INCREASED VALUE OF WORK IS SPECIFIED AS $0.00 ON
 THE REVISION FORM. THE ACTUAL AMOUNT OF THE EXTRA COST
 TO ADD INSULATION TO THIS PROJECT SHOULD BE SPECIFIED
 ON THE FORM.
  
  
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-12-07 Cont ID  
Sent By rmcdouga Date 2018-12-07 Time 11:00 Rev Time 0.00
Received By rmcdouga Date 2018-12-03 Time 13:11 Sent To  
Notes
2018-12-04 13:11:53RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-11-15 Cont ID  
Sent By rmcdouga Date 2018-11-15 Time 18:08 Rev Time 0.00
Received By rmcdouga Date 2018-11-14 Time 14:27 Sent To  
Notes
2018-11-15 14:27:58RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-30 Cont ID  
Sent By rmcdouga Date 2018-08-30 Time 07:12 Rev Time 0.00
Received By rmcdouga Date 2018-08-27 Time 13:13 Sent To  
Notes
2018-08-29 13:13:31REVISION ROUTED TO RMCDOUGAL