Plan Review Details - Permit 18081167
Plan Review Stops For Permit 18081167 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-10-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-10-12 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-10-11 |
Time |
18:42 |
Sent To |
I |
|
Notes |
2018-10-11 19:05:58 | PLAN REVIEW COMMENTS | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PRODUCT APPROVAL THAT WAS SUBMITTED THIS TIME | | NOA NO.13-0521.15 IS FOR ALUMINUM STORM PANELS AND IT | | IS EXPIRED. THE APPLICATION IS FOR ACCORDION SHUTTERS, | | WHICH IS WHAT WAS SUBMITTED THE FIRST TIME FL#1850.3. | | CLARIFY FBC 107.2.1 | | | | 2) THE INFORMATION ON THE INSTALLATION SCHEDULE IS | | INCORRECT. THE WALL PRESSURES ARE WRONG. NONE OF THE | | PRODUCTS WILL WORK FOR WALL PRESSURES OF +110, -120 | | PSF. THE SPAN IS THE LENGTH OF THE SHUTTER BLADES. THE | | ACCORDION SHUTTERS ARE INSTALLED VERTICALLY NOT | | HORIZONTALLY. THE SHUTTER MOUNTING CONNECTION TYPE | | REFERS TO THE WAY THE TOP AND BOTTOM TRACKS ARE | | MOUNTED. FOR PRODUCT APPROVAL FL1850.3, SEE A THROUGH M | | ON SHEETS 6 AND 7. FBC-R301.2.1 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-08-25 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-08-25 |
Time |
12:18 |
Sent To |
I |
|
Notes |
2018-08-25 12:19:48 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT TWO SETS OF A KEY PLAN AND AN ACCORDION | | SHUTTER INSTALLATION SCHEDULE THAT LISTS EACH OF THE | | EIGHT OPENINGS. SPECIFY THE OPENING SIZE, THE WIND | | PRESSURES FOR EACH OPENING, TYPE OF ANCHOR, ANCHOR | | SPACING, EDGE DISTANCE, PANEL LENGTH, PANEL SPAN, | | SEPARATION DISTANCE FROM PANEL TO GLASS AND THE | | APPLICABLE SECTION NUMBER FROM THE INSTALLATION | | DRAWINGS. I HAVE INCLUDED A LINK TO THE CONSTRUCTION | | SERVICES DEPARTMENT SITE THAT HAS MANY OF THE RELATED | | FORMS INCLUDING THE SCHEDULE FOR INSTALLATION OF | | OPENING PROTECTIVE DEVICES. | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-10-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-10-12 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-10-09 |
Time |
14:31 |
Sent To |
|
|
Notes |
2018-10-10 14:31:50 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-08-25 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-08-23 |
Time |
12:44 |
Sent To |
|
|
Notes |
2018-08-24 12:44:15 | BLDG <5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |