Plan Review Details - Permit 18081134
Plan Review Stops For Permit 18081134
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-09-17 Cont ID  
Sent By skennedy Date 2018-09-17 Time 16:51 Rev Time 0.00
Received By skennedy Date 2018-09-17 Time 16:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-10-08 Cont ID  
Sent By jpearson Date 2018-10-08 Time 09:30 Rev Time 0.00
Received By jpearson Date 2018-10-08 Time 09:30 Sent To  
Notes
2018-10-08 09:30:52PASSED UNDER 18080535

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-09-05 Cont ID  
Sent By jpearson Date 2018-09-05 Time 09:28 Rev Time 0.00
Received By jpearson Date 2018-09-05 Time 09:28 Sent To  
Notes
2018-09-05 09:28:41CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLEASE PROVIDE PLAN FOR ADDRESSES. PROVIDE
 CORRECTION. WPB FBC 107.2.1
 2. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED
 TO BEAR THE NAME AND BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. WPB FBC
 107.1, 107.2; FS 471, 481
 3. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. ONLY
 SOME OF THE RECEPTACLE TYPES ARE SHOWN WITH TR. A NOTE
 WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 5. THE NOTE THAT APPEARS TO BE FOR AFCI PROTECTION DOES
 NOT INCLUDE "AFCI", IT JUST SAYS THESE AREAS SHALL BE
 PROTECTED. PROVIDE CORRECTIOIN. NEC 210.12; FBC RE
 E3902
 6. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE
 OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2
 7. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10; FBC RE E3603.3
 8. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL.
 NEC 110.3, 110.9; FBC RE E3603.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-10-10 Cont ID  
Sent By lmarchan Date 2018-10-10 Time 14:43 Rev Time 0.00
Received By lmarchan Date 2018-10-05 Time 10:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-25 Cont ID  
Sent By skennedy Date 2018-09-25 Time 08:24 Rev Time 0.00
Received By skennedy Date 2018-08-30 Time 10:59 Sent To  
Notes
2018-09-04 10:59:30***PLANS UNDER PERMIT 18080535***
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2018-10-10 Cont ID  
Sent By lmarchan Date 2018-10-10 Time 14:43 Rev Time 0.00
Received By lmarchan Date 2018-10-10 Time 14:43 Sent To  
Notes
2018-10-10 14:43:26MU - 2018-33435
 9/25/18 SENT EMAIL TO PBC IMPACT FEE OFFICE

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-09-15 Cont ID  
Sent By cmontell Date 2018-09-15 Time 07:22 Rev Time 0.00
Received By cmontell Date 2018-09-15 Time 07:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-09-25 Cont ID  
Sent By gjohnson Date 2018-09-25 Time 07:18 Rev Time 0.00
Received By gjohnson Date 2018-09-25 Time 07:18 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2018-09-17 Cont ID  
Sent By skennedy Date 2018-09-17 Time 16:51 Rev Time 0.00
Received By skennedy Date 2018-09-17 Time 16:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2018-09-17 Cont ID  
Sent By skennedy Date 2018-09-17 Time 16:51 Rev Time 0.00
Received By skennedy Date 2018-09-17 Time 16:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2018-10-10 Time   Rev Time 0.00
Received By pgreilic Date 2018-10-10 Time 15:36 Sent To  
Notes
2018-10-10 15:36:43LANDSCAPE PERMIT REQUIRED
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2018-09-25 Cont ID  
Sent By skennedy Date 2018-09-25 Time 08:24 Rev Time 0.00
Received By skennedy Date 2018-09-25 Time 08:24 Sent To  
Notes
2018-09-25 08:24:25SEE 18080535 BY PGRELIC