Plan Review Details - Permit 18081115
Plan Review Stops For Permit 18081115 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-12-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-06 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-06 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-18 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-18 |
Time |
15:12 |
Sent To |
|
|
Notes |
2018-10-18 15:18:20 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | BELOW. | | | | 1. FBC B 1609, COMPLETE THE "SCHEDULE FOR INSTALLATION | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | SPREADSHEET): | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS?PAGE=2 | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-09-01 |
|
|
Cont ID |
|
Sent By |
rbrunell |
Date |
2018-08-25 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-08-25 |
Time |
09:50 |
Sent To |
I |
|
Notes |
2018-09-01 17:46:07 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1609, COMPLETE THE "SCHEDULE FOR INSTALLATION | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | SPREADSHEET): | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS?PAGE=2 | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | 3. PROVIDE A PLAN WHICH SHOWS THE FOLLOWING, FBC B | | CHAPTER 10: | | | | FLOOR PLAN WITH DIMENSIONS | | LOCATION OF EXITS | | LOCATION OF INTERIOR WALLS | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE | | | | | | | 2018-08-25 09:53:13 | ADDED 2ND B STOP. FIRST B STOP LOCKED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-12-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-06 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-28 |
Time |
14:10 |
Sent To |
|
|
Notes |
2018-11-29 14:10:32 | RESUB ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-18 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-10 |
Time |
14:33 |
Sent To |
|
|
Notes |
2018-10-11 14:33:42 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-09-01 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
rbrunell |
Date |
2018-08-22 |
Time |
10:27 |
Sent To |
I |
|
Notes |
2018-08-23 10:27:26 | BLDG MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |