Plan Review Details - Permit 18081104
Plan Review Stops For Permit 18081104
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-09-26 Cont ID  
Sent By rmcdouga Date 2018-09-26 Time 14:04 Rev Time 0.00
Received By rmcdouga Date 2018-09-26 Time 14:00 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-10-01 Cont ID  
Sent By jleahy Date 2018-10-01 Time 08:19 Rev Time 0.00
Received By jleahy Date 2018-10-01 Time 08:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-09-04 Cont ID  
Sent By jleahy Date 2018-09-04 Time 16:35 Rev Time 0.00
Received By jleahy Date 2018-09-04 Time 16:35 Sent To  
Notes
2018-09-04 16:43:48FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 2/0'S ONLY APPLY WHEN THE ENTIRE LOAD IS FED FROM ONE
 SET OF SERVICE ENTRANCE CONDUCTORS/FEEDERS. 3/0 ARE
 REQUIRED FOR THE TWO 200A PANELS.
  
 E3603.1.2UNGROUNDED FEEDER CONDUCTORS.
 FOR A FEEDER RATED AT 100 THROUGH 400 AMPERES, THE
 FEEDER CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED
 WITH A ONE-FAMILY DWELLING, OR THE
 FEEDER CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED
 WITH AN INDIVIDUAL DWELLING UNIT IN A TWO-FAMILY
 DWELLING, SHALL HAVE AN AMPACITY OF NOT
 LESS THAN 83 PERCENT OF THE FEEDER RATING.

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2018-09-06 Cont ID  
Sent By lcrespo Date 2018-09-06 Time 07:08 Rev Time 0.00
Received By lcrespo Date 2018-09-06 Time 07:08 Sent To  
Notes
2018-09-06 07:09:0809/06/18 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-10-01 Cont ID  
Sent By jleahy Date 2018-10-01 Time 08:19 Rev Time 0.00
Received By jleahy Date 2018-09-27 Time 15:23 Sent To  
Notes
2018-09-28 15:23:21RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-26 Cont ID  
Sent By rmcdouga Date 2018-09-26 Time 14:04 Rev Time 0.00
Received By rmcdouga Date 2018-08-22 Time 10:59 Sent To  
Notes
2018-08-23 10:59:19ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2018-08-28 Cont ID  
Sent By mcruz Date 2018-08-28 Time 14:36 Rev Time 0.00
Received By mcruz Date 2018-08-28 Time 14:35 Sent To  
Notes
***NONE***