Plan Review Details - Permit 18080814
Plan Review Stops For Permit 18080814 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-14 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-14 |
Time |
15:56 |
Sent To |
|
|
Notes |
2018-11-14 15:58:01 | DEFERRED SUBMITTALS - 1. POLY FOAM ADHESIVE. 2. PEEL | | AND STICK UNDERLAYMENT. 3. EXT. DOOR NOA'S. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-10-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-26 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-26 |
Time |
08:52 |
Sent To |
|
|
Notes |
2018-10-26 09:25:38 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. OWNER AGENT TO SIGN ENERGY SUBMITTAL. | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | _ OR _ | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW DOORS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | 3. PALM BEACH COUNTY IMPACT FEES. | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-09-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-09-06 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-09-06 |
Time |
07:13 |
Sent To |
|
|
Notes |
2018-09-06 16:08:11 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | | | 2. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED. | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | 3. PROVIDE SOILS REPORT PER DESIGNER OF RECORD. | | R401.4 SOIL TESTS. | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | APPROVED METHOD. | | | | 4. PROVIDE PRODUCT APPROVALS FOR WINDOWS, DOORS AND | | ROOFING SYSTEM. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | SUBMITTALS. | | | | 5. PROVIDE DESIGN WIND LOADS FOR ALL WINDOW AND DOOR | | OPENINGS. PROVIDE DESIGN PRESSURES FOR ROOF AREAS WITH | | FASTENER SCHEDULE. | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | | | R301.2.1 WIND DESIGN CRITERIA. | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | GARAGE DOORS). | | | | 6. OWNER AGENT TO SIGN ENERGY SUBMITTAL. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | 7. ALL DOCUMENTS SHALL BE SUBMITTED IN DUPLICATE. | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | APPLICATION. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-14 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-14 |
Time |
15:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-10-15 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-15 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-15 |
Time |
07:12 |
Sent To |
|
|
Notes |
2018-10-15 11:01:50 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. CORRECTED. | | 2. CORRECTED. | | 3. CORRECTED. | | 4. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR PANEL C. NEC 225.31, | | 225.32 (RISER DIAGRAM SHOWS THE REQUIRED DISCONNECT, | | BUT THE ELECTRICAL PLAN DOES NOT. PROVIDE LOCATION OF | | DISCONNECT TO CONFIRM CLEARANCES. NEC 110.26; WPB FBC | | 107.2.1) | | 5. BE ADVISED THAT THE GENERATOR IS NOT INCLUDED IN THE | | SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN | | SUBMITTALS FOR THIS. WPB FBC 105.1, 107.2.1 (NOTE NOT | | PROVIDED.) | | 6. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902 (STILL NOT COMPLIANT. THE | | NOTE PROVIDED STATES THAT RECEPTACLES SHALL BE AFCI | | PROTECTED. IT IS NOT JUST THE RECEPTACLES THAT REQUIRE | | AFCI PROTECTION. SEE NOTE ABOVE.) | | 7. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | LOADS SPECIFIED IN THE FBC RESIDENTIAL EDITION. SEE | | CODE FOR PROPER FORMAT AND ALLOWABLE DEMAND FACTORS. | | NEC 220; FBC RE E3602.2 (LOAD PROVIDED NOT CORRECT. | | ONLY THE PORTION OVER 10,000 VA IS PERMITTED TO USE THE | | DEMAND FACTOR OF 40%. ADDITIONALLY, A LOAD CALCULATION | | FOR THE MAIN SERVICE IS REQUIRED TO CONFIRM THE SIZE | | SPECIFIED IS SUFFICIENT, SEE NOTE 9.) | | 8. PROVIDE RISER DIAGRAM FROM MAIN HOUSE WHERE POWER | | WILL BE FED FROM, SHOWING ALL DETAILS OF SERVICE | | EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND | | BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S). | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB FBC | | 107.2.1 (RISER PROVIDED IS NOT CODE COMPLIANT. RISER | | SHOWS A 1 1/4 NIPPLE WITH THREE 4/0 WIRES FEEDING THE | | 100 AMP MAIN BREAKER. THIS CONDUIT IS NOT SIZED | | APPROPRIATELY FOR THE WIRE SPECIFIED. PROVIDE | | CORRECTION. NEC ANNEX C.) | | 9. PROVIDE LOAD CALCULATION FOR EXISTING SERVICE, | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | E3602.2 (NOT PROVIDED.) | | 10. CORRECTED. | | 11. CORRECTED. | | 12. CORRECTED. | | | | NEW COMMENTS: | | | | 13. PLAN SHOWS A NEW SERVICE. PROVIDE AVAILABLE SHORT | | CIRCUIT CALCULATION FOR EACH PANEL INCLUDING | | INFORMATION FROM THE POWER COMPANY STATING WHAT THE | | AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO | | CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT | | AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, 110.10; | | FBC RE E3606.3 | | 14. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | NEC 110.3, 110.9; FBC RE E3603.3 | | 15. GENERATOR TRANSFER SWITCH IS SHOWN BEHIND THE | | GENERATOR. PROVIDE CORRECTION FOR CLEARANCE. NEC | | 110.26; FBC RE E3405.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-08-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-29 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-29 |
Time |
06:42 |
Sent To |
|
|
Notes |
2018-08-29 15:42:30 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | PERMITTED. PROVIDE CORRECTION. WPB FBC 107.2.1; NEC | | 230.2; FBC RE E3601.2 | | 2. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | FEEDER OR BRANCH CIRCUIT. NEC 225.30 | | 3. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | 4. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR PANEL. NEC 225.31, 225.32 | | 5. BE ADVISED THAT THE GENERATOR IS NOT INCLUDED IN THE | | SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN | | SUBMITTALS FOR THIS. WPB FBC 105.1, 107.2.1 | | 6. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902 | | 7. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | LOADS SPECIFIED IN THE FBC RESIDENTIAL EDITION. SEE | | CODE FOR PROPER FORMAT AND ALLOWABLE DEMAND FACTORS. | | NEC 220; FBC RE E3602.2 | | 8. PROVIDE RISER DIAGRAM FROM MAIN HOUSE WHERE POWER | | WILL BE FED FROM, SHOWING ALL DETAILS OF SERVICE | | EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND | | BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S). | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB FBC | | 107.2.1 | | 9. PROVIDE LOAD CALCULATION FOR EXISTING SERVICE, | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | E3602.2 | | 10. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 | | 11. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | 12. PLAN SHOWS ONE SMALL APPLIANCE CIRCUIT FOR KITCHEN | | RECEPTACLE OUTLETS. A MINIMUM OF TWO 20 AMPERE BRANCH | | CIRCUIT SHALL BE PROVIDED TO SUPPLY KITCHEN COUNTERTOP | | RECEPTACLE OUTLET(S). PROVIDE CORRECTION. NEC | | 210.11(C)(1) , FBC RE E3703.2 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2018-10-23 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-23 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-25 |
Time |
08:00 |
Sent To |
|
|
Notes |
2018-10-23 15:41:47 | PLAN SHEET E-1; A GAS TANKLESS WATER HEATER IS SHOWN ON | | THE PLAN. | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | 107.2.1. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | INSTALLATION OR MODIFICATION OF SYSTEM. | | IF THERE IS AN EXISTING SYSTEM, THE BTU LOAD OF THE | | EXISTING GAS SYSTEM MUST BE ADDED INTO THE TOTAL BTU | | LOAD ON THE SYSTEM TO ENSURE THE EXISTING SYSTEM IS | | PROPERLY SIZED. IF UNDERSIZED, THE EXISTING SYSTEM MUST | | BE REDONE TO ENSURE A SAFE OPERATING SYSTEM. SUBMIT A | | GAS PIPING RISER DIAGRAM THAT SHOWS THE TYPE OF | | EXISTING APPLIANCE, THE BTU LOAD OF EACH APPLIANCE, THE | | PIPE SIZE AND TYPE OF PIPE TO EACH APPLIANCE, AND THE | | DISTANCE OF THE LONGEST LENGTH OF PIPING FROM THE POINT | | OF DELIVERY TO THE MOST REMOTE OUTLET AND THE LOAD OF | | THE SECTION. NOTE: IF THE EXISTING SYSTEM IS LESS THAN | | A 2 PSI SYSTEM AND THE SYSTEM PRESSURE IS INCREASED TO | | 2 PSI, A LINE PRESSURE REGULATOR IS REQUIRED AT ALL THE | | EXISTING APPLIANCES. FBCR SECS.G2412.4, G2412.8, | | G2413.1, G2413.2, G2413.3. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-11-13 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-11-13 |
Time |
10:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-08-24 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-08-24 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-11-14 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-11-14 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-11-13 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-10-09 |
Time |
09:17 |
Sent To |
|
|
Notes |
2018-10-18 11:18:47 | R30 | 2018-10-11 09:17:31 | LIBRARY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-09-11 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-09-11 |
Time |
14:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-11-19 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-11-14 |
Time |
16:04 |
Sent To |
|
|
Notes |
2018-11-19 08:40:30 | MU2018-038700-0000 $0.00 FEE | 2018-11-14 16:04:30 | CHECKED OUT A SET TO RUSS. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-10-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-26 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-26 |
Time |
08:58 |
Sent To |
|
|
Notes |
2018-10-26 08:59:47 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-11-14 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-11-14 |
Time |
16:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-10-15 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-10-15 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-10-15 |
Time |
12:57 |
Sent To |
|
|
Notes |
2018-10-15 12:59:42 | MECH PLAN REVIEW FAIL | | | | 1 - 107.2.1.3 QUALITY OF BUILDING PLANS. | | BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 | | INCH SCALE | | | | CHRIS MONTELLO | | 561-805-6733 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-09-07 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-09-07 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-09-07 |
Time |
15:02 |
Sent To |
|
|
Notes |
2018-09-07 15:08:52 | MECHANICAL PLAN REVIEW FAIL | | | | 1 - NEED MECHANICAL PLANS PER. FBC. SEC. [A]107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | CHRIS MONTELLO | | 561-805-6733 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-11-14 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-11-14 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-10-25 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-25 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-25 |
Time |
08:00 |
Sent To |
|
|
Notes |
2018-10-25 07:59:23 | 2ND REVIEW: | | PLUMBING COMMENTS: APPROVED | | | | PROVISO | | 1. TUB/SHOWER CONTROL VALVE(S) SHALL BE ANTI-SCALD TYPE | | WITH HIGH TEMPERATURE LIMITING STOP. FBC RES P2708.4 | | 2. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLY TO | | ICE LINE. FBC RES P2903.5 | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-09-11 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-09-11 |
Time |
14:15 |
Sent To |
|
|
Notes |
2018-09-11 14:34:08 | 1ST REVIEW: FBC 2017 6TH EDITION | | PERMIT 180814 | | PLUMBING COMMENTS: | | | | 1. RE: PLAN SHEET E-1; SHOW TRAP ON ALL UNDERFLOOR | | FIXTURE DRAINS, IE. BATHTUBS AND SHOWERS, UNLESS | | FIXTURE IS INTEGRALLY TRAPPED, IE. WATER CLOSETS. FBC | | WPB AMEND 107.2.1, FBC RES P3201.2B. CIRCLE SYMBOLS AT | | END OF HORIZONTAL PIPING FOR WATER CLOSETS ARE | | CONFUSING. PROVIDE VERTICAL EXTENSION AT END OF WATER | | CLOSET HORIZONTAL AND PLACE OVAL SYMBOL AT TOP PER FBC | | WPB AMEND 107.2.1. | | 2. RE: PLAN SHEET E-1; SHOWS SHOWER AND WATER CLOSET | | FIXTURE DRAINS SHOWN CONNECTING TO EACH OTHER BEFORE | | CONNECTING TO(WET)VENT. MUST CONNECT INDEPENDENTLY TO | | VENT FBC RES 3108.1; FIXTURE DRAIN LENGTH TRAP TO VENT | | TO BE IN ACCORDANCE WITH FBC RES TABLE P3105.1. | | 3. ADD PLUMBING NOTE: SHOWER CONTROL VALVE(S) SHALL BE | | PRESSURE BALANCED PB,THERMOSTATIC MIXING (TM) OR | | COMBINATION PB/TM VALVE TYPES WITH HIGH TEMPERATURE | | LIMITING STOP. 2017 FBC RES 2708.4 | | 4. RE: PLAN SHEET E-1; A GAS TANKLESS WATER HEATER IS | | SHOWN ON THE PLAN. | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | 107.2.1. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | INSTALLATION OR MODIFICATION OF SYSTEM. | | IF THERE IS AN EXISTING SYSTEM, THE BTU LOAD OF THE | | EXISTING GAS SYSTEM MUST BE ADDED INTO THE TOTAL BTU | | LOAD ON THE SYSTEM TO ENSURE THE EXISTING SYSTEM IS | | PROPERLY SIZED. IF UNDERSIZED, THE EXISTING SYSTEM MUST | | BE REDONE TO ENSURE A SAFE OPERATING SYSTEM. SUBMIT A | | GAS PIPING RISER DIAGRAM THAT SHOWS THE TYPE OF | | EXISTING APPLIANCE, THE BTU LOAD OF EACH APPLIANCE, THE | | PIPE SIZE AND TYPE OF PIPE TO EACH APPLIANCE, AND THE | | DISTANCE OF THE LONGEST LENGTH OF PIPING FROM THE POINT | | OF DELIVERY TO THE MOST REMOTE OUTLET AND THE LOAD OF | | THE SECTION. NOTE: IF THE EXISTING SYSTEM IS LESS THAN | | A 2 PSI SYSTEM AND THE SYSTEM PRESSURE IS INCREASED TO | | 2 PSI, A LINE PRESSURE REGULATOR IS REQUIRED AT ALL THE | | EXISTING APPLIANCES. FBCR SECS.G2412.4, G2412.8, | | G2413.1, G2413.2, G2413.3. | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6715 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-10-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-26 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-26 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-11-13 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-11-13 |
Time |
10:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-08-24 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-08-24 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
|