Plan Review Details - Permit 18080811
Plan Review Stops For Permit 18080811
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-08-30 Cont ID  
Sent By jwitmer Date 2018-08-30 Time 14:19 Rev Time 0.00
Received By shill Date 2018-08-30 Time 14:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-08-28 Cont ID  
Sent By jpearson Date 2018-08-28 Time 14:49 Rev Time 0.00
Received By jleahy Date 2018-08-28 Time 14:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-30 Cont ID  
Sent By gjohnson Date 2018-08-30 Time 16:23 Rev Time 0.00
Received By gjohnson Date 2018-08-15 Time 16:06 Sent To  
Notes
2018-08-16 16:06:54B08

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-08-30 Cont ID  
Sent By ccole Date 2018-08-30 Time 14:25 Rev Time 0.00
Received By cmontell Date 2018-08-30 Time 13:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-08-31 Cont ID  
Sent By tklarge Date 2018-08-31 Time 14:38 Rev Time 0.00
Received By tklarge Date 2018-08-31 Time 14:38 Sent To  
Notes
2018-08-31 14:41:07THIS IS A BUSINESS OCCUPANCY OF 1040 SQUARE FEET. 1040
 DIVIDED BY 100 = 10.4 PERSONS AND A DRINKING FOUNTAIN
 AND SERVICE SINK IS NOT REQD. PER THE PLUMBING CODE.
 TKL.

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-08-30 Cont ID  
Sent By gjohnson Date 2018-08-30 Time 16:16 Rev Time 0.00
Received By gjohnson Date 2018-08-30 Time 16:16 Sent To  
Notes
2018-08-30 16:22:551ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS: SHALL COMPLY WITH PROVISO FROM
 MASTER.
  
 PLUMBING PROVISO:
 REQUIRED BEFORE FIRST ROUGH INSPECTION.
 1. PROVIDE A SERVICE SINK PER FBC EX 1010.1 AND FBC PL
 TABLE 403.1
 2. PROVIDE A WATER FOUNTAIN FBC PL TABLE 403.1 SHALL
 COMPLY WITH FBC ACC 211.2
 3. WATER HEATER SHALL BE SIZED TO PROVIDE HOT WATER TO
 ALL FIXTURES AT PEAK LOAD PROVIDE MANUFACTURE
 SPECIFICATIONS ON JOBSITE FOR INSPECTIONS. PER WPB
 AMEND TO FBC 107.2.1 AND FBC PL 607.1
  
 NEW COMMENTS:
  
 1. THE THIRD DELETED SHAMPOO SINK IS STILL SHOWN ON THE
 PIPING OF THE PLUMBING PLAN WATER AND SANITARY. PLEASE
 CLARIFY PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  