Plan Review Details - Permit 18080076
Plan Review Stops For Permit 18080076 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-09-11 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-09-11 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-08-27 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-27 |
Time |
08:25 |
Sent To |
|
|
Notes |
2018-08-27 08:29:33 | RESIDENTIAL (R3) RE-ROOF THIRD BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: | | NEW ROOF TILE NOA 18-0509.19 SUBMITTED. THIS IS OK BUT | | STILL NEED THE PRODUCT APPROVAL FOR THE ROOF TILE | | UNDERLAYMENT FOR ADHESIVE APPLICATIONS. SEE PREVIOUS | | COMMENT BELOW. | | | | | | ORIGINAL COMMENT: | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR "ICE & WATER | | SHIELD" UNDERLAYMENT SPECIFIED ON THE "MEASUREMENTS" | | PAGE SUBMITTED TO VERIFY THAT UNDERLAYMENT IS DESIGNED | | FOR CONCRETE TILES WITH ADHESIVE INSTALLATIONS AS | | REQUIRED BY LIMITATION #5.4 OF ROOF TILE PRODUCT | | APPROVAL FL7473-R8 AND BY LIMITATION #5.5 OF ROOF TILE | | ADHESIVE PRODUCT APPROVAL FL6332-R8 SUBMITTED. | | FAC 61G20-3.001. | | | | RESPONSE: | | TAMKO ROOFING UNDERLAYMENT FL12328-R8 SUBMITTED CAN NOT | | BE USED FOR ROOF TILE WITH ADHESIVE APPLICATIONS. | | UNDERLAYMENT SUBMITTED REQUIRES ALL ROOF COVERINGS TO | | BE MECHANICALLY FASTENED. SEE LAST NOTE OF APPLICATION | | METHOD ON PAGE 2 OF 4 OF FLORIDA PRODUCT APPROVAL | | SUBMITTED. PROVIDE PRODUCT APPROVAL OF UNDERLAYMENT | | THAT IS APPROVED FOR ADHESIVE INSTALLATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-08-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-08-13 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-13 |
Time |
09:35 |
Sent To |
|
|
Notes |
2018-08-13 09:37:21 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR "ICE & WATER | | SHIELD" UNDERLAYMENT SPECIFIED ON THE "MEASUREMENTS" | | PAGE SUBMITTED TO VERIFY THAT UNDERLAYMENT IS DESIGNED | | FOR CONCRETE TILES WITH ADHESIVE INSTALLATIONS AS | | REQUIRED BY LIMITATION #5.4 OF ROOF TILE PRODUCT | | APPROVAL FL7473-R8 AND BY LIMITATION #5.5 OF ROOF TILE | | ADHESIVE PRODUCT APPROVAL FL6332-R8 SUBMITTED. | | FAC 61G20-3.001. | | | | RESPONSE: | | TAMKO ROOFING UNDERLAYMENT FL12328-R8 SUBMITTED CAN NOT | | BE USED FOR ROOF TILE WITH ADHESIVE APPLICATIONS. | | UNDERLAYMENT SUBMITTED REQUIRES ALL ROOF COVERINGS TO | | BE MECHANICALLY FASTENED. SEE LAST NOTE OF APPLICATION | | METHOD ON PAGE 2 OF 4 OF FLORIDA PRODUCT APPROVAL | | SUBMITTED. PROVIDE PRODUCT APPROVAL OF UNDERLAYMENT | | THAT IS APPROVED FOR ADHESIVE INSTALLATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-08-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-08-03 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-03 |
Time |
08:32 |
Sent To |
|
|
Notes |
2018-08-03 09:46:27 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR "ICE & WATER | | SHIELD" UNDERLAYMENT SPECIFIED ON THE "MEASUREMENTS" | | PAGE SUBMITTED TO VERIFY THAT UNDERLAYMENT IS DESIGNED | | FOR CONCRETE TILES WITH ADHESIVE INSTALLATIONS AS | | REQUIRED BY LIMITATION #5.4 OF ROOF TILE PRODUCT | | APPROVAL FL7473-R8 AND BY LIMITATION #5.5 OF ROOF TILE | | ADHESIVE PRODUCT APPROVAL FL6332-R8 SUBMITTED. | | FAC 61G20-3.001. | | | | 2- CLEARLY MARK THE ADHESIVE PADDY SIZE ON TABLES 1 AND | | TABLE 2 OF ADHESIVE PRODUCT APPROVAL SUBMITTED AS | | REQUIRED BY CITY POLICY FOR ROOFING PERMITS TO VERIFY | | COMPLIANCE WITH PROPOSED INSTALLATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-09-11 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-09-11 |
Time |
10:41 |
Sent To |
|
|
Notes |
2018-09-11 10:41:28 | MET W/ BILL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-08-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-08-27 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-27 |
Time |
08:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-08-13 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-09 |
Time |
10:54 |
Sent To |
I |
|
Notes |
2018-08-10 10:54:43 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-08-03 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-02 |
Time |
12:59 |
Sent To |
I |
|
Notes |
2018-08-02 13:00:00 | JGOMEZ |
|
|
|