Plan Review Details - Permit 18071394
Plan Review Stops For Permit 18071394
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-27 Cont ID  
Sent By dbattles Date 2018-08-27 Time 11:26 Rev Time 0.00
Received By dbattles Date 2018-08-27 Time 11:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-08-06 Cont ID  
Sent By dbattles Date 2018-08-06 Time 15:59 Rev Time 0.00
Received By dbattles Date 2018-08-06 Time 15:59 Sent To  
Notes
2018-08-06 16:07:18****CORRECTIONS****
 W.P.B. PERMIT: 18071394
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC EB = FBC EXISTING BUILDING
 FBC R = FBC RESIDENTIAL
  
 1. FOOTER WILL NEED TO BE LOCATED ENTIRELY ON PROPERTY.
 INDICATE HOW FAR FROM PROPERTY LINE TO ACHIEVE.
 ECCENTRICALLY LOADED FOOTER CAN BE UTILIZED TO GET WALL
 CLOSER TO THE PROPERTY LINE.
  
 2. PROVIDE CUT SHEET WITH MASONRY ATTACHMENT FOR THE
 STONE VENEER.
 WHAT IS THE FINISH ON EAST SIDE OF WALL?
  
 3. ADJUST NOTES UNDER CONCRETE AS THEY GOT JUMBLED.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2018-08-24 Cont ID  
Sent By destabro Date 2018-08-24 Time 11:51 Rev Time 0.00
Received By destabro Date 2018-08-24 Time 11:51 Sent To Z
Notes
2018-08-24 11:52:028/24/2018 - STUCCO-CLAD 6' CMU WALL MEETS DESIGN
 GUIDELINES OF HISTORIC DISTRICT. DLE

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2018-08-01 Cont ID  
Sent By destabro Date 2018-08-01 Time 14:00 Rev Time 0.00
Received By destabro Date 2018-08-01 Time 14:00 Sent To B
Notes
2018-08-01 14:04:028/1/2018 - PLEASE INCLUDE WALL ELEVATION DETAIL THAT
 SHOWS EXTERIOR CLADDING (PAINTED CONCRETE? STUCCO?) AND
 FINISHING FOR TOP OF WALL TO INCLUDE ANY COLUMNS OR
 ACCENTS. QUESTIONS MAY BE DIRECTED TO DESIREE
 ESTABROOK, HISTORIC PRESERVATION PLANNER AT
 561.822.1428 OR [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-27 Cont ID  
Sent By dbattles Date 2018-08-27 Time 11:26 Rev Time 0.00
Received By dbattles Date 2018-08-20 Time 14:45 Sent To  
Notes
2018-08-21 14:45:55ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-06 Cont ID  
Sent By dbattles Date 2018-08-06 Time 16:07 Rev Time 0.00
Received By dbattles Date 2018-07-30 Time 10:43 Sent To  
Notes
2018-07-31 10:43:28ROUTED TO HISTORIC INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2018-08-24 Cont ID  
Sent By destabro Date 2018-08-24 Time 11:52 Rev Time 0.00
Received By destabro Date 2018-08-24 Time 11:52 Sent To B
Notes
2018-08-24 11:52:558/24/2018 - PROPOSED 6' HEIGHT BEHIND FRONT 25' SETBACK
 MEETS ZONING STANDARDS. DLE

Review Stop Z ZONING
Rev No 1 Status F Date 2018-08-01 Cont ID  
Sent By destabro Date 2018-08-01 Time 14:00 Rev Time 0.00
Received By destabro Date 2018-08-01 Time 13:59 Sent To HIST
Notes
2018-08-01 14:00:518/1/2018 - IF WALL IS TO BE PLACED ALONG EASTERN
 PROPERTY LINE, INCLUDE UTILITY EASEMENT FORMS. PLEASE
 DIRECT QUESTIONS TO DESIREE ESTABROOK, HISTORIC
 PRESERVATION PLANNER AT 561.822.1428 OR
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved