|
 |
 |
 |
 |
 |
Plan Review Details - Permit 18071335
Plan Review Stops For Permit 18071335 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-08-07 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-08-07 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-08-07 |
Time |
16:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-08-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-08-03 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-08-03 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2018-09-04 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-09-04 |
Time |
18:06 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-09-04 |
Time |
18:06 |
Sent To |
|
|
Notes |
2018-09-04 18:12:09 | 09/04/18 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2018-08-31 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-08-07 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-08-07 |
Time |
11:50 |
Sent To |
|
|
Notes |
2018-08-07 12:08:05 | GAS PLAN REVIEW,THE PLAN HAVE A EXSISTING GAS HEATER | | THAT HAS NO RECORDS IN THE CITY RECIEVING APPLICATION, | | PLAN REVIEW OR FINAL INSPECTION ON THE SYSTEM. A GAS | | PLAN REVIEW CAN NOT BEEN PERFORMED AT THIS TIME. A | | SEPARATE GAS PERMIT AND PLANS WILL BE REQUIRED FOR A | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | COMPLETE PLANS AND GAS RISER THAT REFLECTS THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. AT THIS TIME. WPB | | AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-09-04 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-09-04 |
Time |
18:06 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-08-31 |
Time |
13:54 |
Sent To |
|
|
Notes |
2018-09-04 13:55:05 | RESUB ROUTED TO LCRESPO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-07 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-08-07 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-07-27 |
Time |
13:09 |
Sent To |
|
|
Notes |
2018-07-30 13:09:24 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-08-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-08-07 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-08-07 |
Time |
11:50 |
Sent To |
|
|
Notes |
2018-09-04 18:12:50 | 09/04/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-08-01 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-08-01 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-08-01 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |