Plan Review Details - Permit 18071126
Plan Review Stops For Permit 18071126 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-12-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2018-12-04 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-12-04 |
Time |
07:43 |
Sent To |
|
|
Notes |
2018-12-04 08:12:23 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | APPROVED WITH PROVISO: | | | | PRIOR TO INSPECTIONS, PLEASE RESOLVE EXPIRED PERMIT | | ISSUE FOR PERMIT # 12080369 (A/C CHANGE-OUT). | | | | PRIOR TO ROOF WORK, PLEASE HAVE ROOFING PRODUCT | | APPROVALS ON SITE FOR INSPECTOR. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-11-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-02 |
Time |
20:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-11-02 |
Time |
20:10 |
Sent To |
|
|
Notes |
2018-11-02 20:59:01 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 1. A1A STATES THAT THE EXISTING PARKING LOT IS TO | | REMAIN. SEE FBC A 202.1, 202.4, PATH OF TRAVEL IS TO BE | | ACCESSIBLE. A2 DOES NOT SHOW ANY ACCESSIBLE SPACES; A1A | | DOES NOT SHOW AN ACCESS AISLE FOR THE "EXISTING | | HANDICAP PARKING SPACE". AERIALS APPEAR TO SHOW NO | | STRIPING. THERE IS NO RECORD OF A PAVING OR RESTRIPE | | PERMIT. | | | | ALSO PLEASE CONFIRM THAT THE "EXISTING RAMP" COMPLIES | | WITH FBC ACCESSIBILITY AS I WAS UNABLE TO FIND A PERMIT | | FOR THIS WORK. IF IT COMPLIES, PLEASE NOTE THAT YOU | | HAVE CONFIRMED COMPLIANCE ON THE PLAN. IF IT DOES NOT | | COMPLY, PLEASE REVISE PLAN. | | | | SEE ALSO PLUMBING COMMENTS. | | | | 2ND REVIEW - SEE FBC A 502.4 AND ADVISORY. THE ACCESS | | AISLE IS TO BE THE LENGTH OF THE ACCESSIBLE SPACE PER | | 502.3.2 AND IS REQUIRED TO BE LEVEL. THE RAMP | | ENCROACHES ONTO THE AREA WHICH SHOULD BE ACCESS AISLE. | | ACCESS AISLE IS TOO SHORT. NO DIMENSIONS WERE PROVIDED. | | | | THERE IS A STATEMENT THAT THE RAMP COMPLIES AND IS | | 1:12. HOWEVER, THERE IS NO INFORMATION REGARDING EDGE | | PROTECTION OR RAILINGS (CANNOT DETERMINE IF THEY ARE | | REQUIRED AS DIMENSION/RUN NOT PROVIDED), LANDINGS NOT | | SHOWN 405.7 (NOTE 60X60 REQUIRED AT TOP WHERE THERE IS | | A CHANGE IN DIRECTION). | | | | PARKING IS NOT CONSIDERED "EXISTING" AS THERE IS NO | | PERMIT FOR THE STRIPING. A PERMIT APPLICATION AND PLAN | | SHOULD BE SUBMITTED AFTER THE ACCESSIBLE ROUTE ISSUE IS | | RESOLVED. | | | | 2-4. OK | | | | 5. ON THE DOOR PRODUCT APPROVAL, INDICATE WHICH | | THRESHOLD OPTION IS SELECTED TO SHOW COMPLIANCE WITH | | FBC A 303. | | | | 2ND REVIEW, A SILL RATHER THAN A THRESHOLD WAS | | INDICATED. HEIGHT THAT CONTRACTOR MARKED IS 1.376; SEE | | FBC A 303.2, .25" MAX VERTICAL CHANGE ALLOWED. | | | | 6. FIXED GLASS PRODUCT APPROVALS - SUBMITTED AND OK | | | | ROOF PRODUCT APPROVALS WERE NOT SUBMITTED. DO YOU WANT | | FOR THIS TO BE DEFFERED? FBC 107. IF NOT PROVIDED, THIS | | PERMIT WILL BE ISSUED WITH PROVISO, ROOF PRODUCT | | APPROVALS REVIEWED BY DESIGNER OF RECORD REQUIRED WITH | | ROOF PERMIT APPLICATION PRIOR TO INSTALLATION. | | | | 7-8. OK | | | | NEW COMMENTS: | | | | 9. THE STRUCTURAL PAGES ARE NOT SIGNED AND SEALED, | | FS471. | | | | 10. A SECOND RAMP IS SHOWN AT THE REAR OF THE BUILDING, | | NEAR THE OUTDOOR COOLER. IT IS NOT CLEAR WHAT THE | | PURPOSE OF THIS RAMP IS. IT DOES NOT APPEAR TO BE IN | | THE ACCESSIBLE ROUTE; IF NOT IN THE ACCESSIBLE ROUTE, | | THE NOTE IS NOT NECESSARY, FBC 107. | | | | 11. "ROUGH ESTIMATE" APPEARS LOW FBC 109. | | | | 12. IF THE ACCESSIBLE ROUTE AND FRENCH DOOR ISSUES CAN | | BE RESOLVED VIA EMAIL, MEETING, OR TELEPHONE CALL, IT | | IS POSSIBLE THAT THIS REVIEW CAN BE PASSED WITH PROVISO | | FOR A REVISION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-08-25 |
Time |
19:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-08-25 |
Time |
19:10 |
Sent To |
|
|
Notes |
2018-08-25 19:10:30 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. A1A STATES THAT THE EXISTING PARKING LOT IS TO | | REMAIN. SEE FBC A 202.1, 202.4, PATH OF TRAVEL IS TO BE | | ACCESSIBLE. A2 DOES NOT SHOW ANY ACCESSIBLE SPACES; A1A | | DOES NOT SHOW AN ACCESS AISLE FOR THE "EXISTING | | HANDICAP PARKING SPACE". AERIALS APPEAR TO SHOW NO | | STRIPING. THERE IS NO RECORD OF A PAVING OR RESTRIPE | | PERMIT. | | | | ALSO PLEASE CONFIRM THAT THE "EXISTING RAMP" COMPLIES | | WITH FBC ACCESSIBILITY AS I WAS UNABLE TO FIND A PERMIT | | FOR THIS WORK. IF IT COMPLIES, PLEASE NOTE THAT YOU | | HAVE CONFIRMED COMPLIANCE ON THE PLAN. IF IT DOES NOT | | COMPLY, PLEASE REVISE PLAN. | | | | SEE ALSO PLUMBING COMMENTS. | | | | 2. A5, SOME NOTES ARE TOO SMALL TO READ, REVISE, FBC | | 107. | | | | 3. FBC B 1004, REVISE PLAN TO INCLUDE OCCUPANCY | | CLASSIFICATION AND OCCUPANT LOAD. | | | | 4. FBC B 107, IF THIS IS A2 WITH AN OCCUPANT LOAD OVER | | 50, PANIC BARS REQUIRED. IF REQUIRED, INDICATE THIS | | OPTION ON THE DOOR PRODUCT APPROVAL. | | | | 5. ON THE DOOR PRODUCT APPROVAL, INDICATE WHICH | | THRESHOLD OPTION IS SELECTED TO SHOW COMPLIANCE WITH | | FBC A 303. | | | | 6. FIXED GLASS PRODUCT APPROVALS AND ROOF PRODUCT | | APPROVALS WERE NOT SUBMITTED. DO YOU WANT FOR THIS TO | | BE DEFFERED? FBC 107. | | | | 7. THIS PROPERTY HAS TWO EXPIRED PERMITS, PLEASE | | ADDRESS, FBC 107. | | | | 8. FBC 107, PRODUCT APPROVALS TO BE REVIEWED BY | | DESIGNER OF RECORD. | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-11-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-27 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-27 |
Time |
14:54 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-10-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-09 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-09 |
Time |
08:03 |
Sent To |
|
|
Notes |
2018-10-09 08:03:00 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | SERVICE IS ADEQUATE. BASED ON THE LAST PERMIT THAT WAS | | ISSUED FOR THIS LOCATION, PERMIT 12010158, THERE ARE | | MANY ITEMS INSTALLED THAT ARE NOT INCLUDED IN THE LOAD | | CALCULATION, INCLUDING WALK IN COOLER, ADDITIONAL WINE | | COOLER AND BEER COOLERS, A SUB-PANEL NAMED PANEL B, AND | | MINI-SPLIT UNITS. NEC 215.2, 220, 408.30 (PROVIDE | | DETAIL OF KITCHEN EQUIPMENT THAT IS INCLUDED IN THE | | 65%DEMAND FACTOR USED. I DO NOT SEE 6 ITEMS THAT | | QUALIFY FOR THIS DEMAD ON PANEL SCHEDULE AS EXPLAINED | | IN NEC 220.56. PROVIDE ACCURATE CALCULATION AS | | PREVIOUSLY REQUESTED.) | | 2. IF ABOVE CALCULATION RESULTS IN EXCEEDING THE | | CAPACITY OF THE CURRENT SERVICE, PROVIDE CORRECTION. | | NEC 215.2, 240.4, 310.15, 408.30, 408.36 (AFTER | | CORRECTION IN COMMENT 1, APPLY AS APPLICABLE.) | | 3. PROVIDE ACCURATE RISER DIAGRAM, SHOWING ALL DETAILS | | OF SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 (NO ELECTRICAL RISER DIAGRAM ON | | PLAN.) | | 4. CORRECTED. | | | | NEW COMMENT: | | | | 5. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC | | 210.63 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-08-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-16 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-16 |
Time |
14:41 |
Sent To |
|
|
Notes |
2018-08-16 14:41:28 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | SERVICE IS ADEQUATE. BASED ON THE LAST PERMIT THAT WAS | | ISSUED FOR THIS LOCATION, PERMIT 12010158, THERE ARE | | MANY ITEMS INSTALLED THAT ARE NOT INCLUDED IN THE LOAD | | CALCULATION, INCLUDING WALK IN COOLER, ADDITIONAL WINE | | COOLER AND BEER COOLERS, A SUB-PANEL NAMED PANEL B, AND | | MINI-SPLIT UNITS. NEC 215.2, 220, 408.30 | | 2. IF ABOVE CALCULATION RESULTS IN EXCEEDING THE | | CAPACITY OF THE CURRENT SERVICE, PROVIDE CORRECTION. | | NEC 215.2, 240.4, 310.15, 408.30, 408.36 | | 3. PROVIDE ACCURATE RISER DIAGRAM, SHOWING ALL DETAILS | | OF SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 | | 4. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-10-09 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-10-09 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-10-09 |
Time |
11:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-07-31 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-07-31 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-07-31 |
Time |
15:09 |
Sent To |
|
|
Notes |
2018-07-31 15:17:32 | PERMIT # 18071126 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | FAILED COMMENTS: | | | | 1) PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | TRAVEL ETC. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-12-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2018-12-04 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-11-19 |
Time |
09:37 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-11-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-02 |
Time |
20:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-10-02 |
Time |
10:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-08-25 |
Time |
19:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-24 |
Time |
09:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-11-26 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2018-12-04 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-11-26 |
Time |
17:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-10-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-10-22 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-10-22 |
Time |
12:41 |
Sent To |
|
|
Notes |
2018-10-22 13:01:38 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #18071126 | | 10/22/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | AC SYSTEM- SECTION C403.2.1 FBC-17 ENERGY CONSERVATION. | | | | 2) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE | | DINING AND BAR ROOMS- TABLE 403.3.1 FBC-17 MECHANICAL. | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | PROVIDED CFMS OF OUTDOOR AIR. | | | | 3) PROVIDE AN AIR DEVICE SCHEDULE AND INDICATE THE | | SUPPLY CFMS AT EACH DIFFUSER ON THE PLAN. SHOW THE | | LOCATION OF THE MAIN RETURN GRILL AND PROVIDE | | DIMENSIONS- SECTION 603.1 FBC M. | | | | 4) PROVIDE A CONDENSATE DISPOSAL PLAN- SECTION 307 FBC | | M. SHOW THE TYPE OF PRIMARY PIPING, THE PIPING RUN AND | | DISCHARGE LOCATION. | | | | 5) PROVIDE WIND LOAD ENGINEERING FOR TIE DOWN OF THE | | NEW CONDENSER- SECTION 301.15 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-08-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-08-08 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-08-08 |
Time |
08:48 |
Sent To |
|
|
Notes |
2018-08-08 08:54:28 | 1ST REVIEW FBC-2017 MECHANICAL | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) NO MECHANICAL PLANS WERE SUBMITTED WITH THE PLAN | | SETS, HPOWEVER A NEW AC SYSTEM IS REFERENCED IN THE | | ARCHITECTURAL PLANS. PLEASE PROVIDE COMPLETE MECHANICAL | | PLANS AND SPECIFICATIONS FOR REVIEW FOR THE PROPOSED | | PROJECT- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2018-10-31 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-10-31 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-10-31 |
Time |
15:28 |
Sent To |
|
|
Notes |
2018-10-31 15:30:47 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: NO PLUMBING SHOWN ON PLAN, PER | | RESPONSE LETTER FROM ARCHITEC PLUMBING IS EXISTING TO | | REMAIN. | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-08-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-08-24 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-08-24 |
Time |
06:41 |
Sent To |
|
|
Notes |
2018-08-24 10:03:37 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. NO PLUMBING SHOWN ON PLAN PLEASE PROVIDE DETAILED | | SCOPE OF ANY PLUMBING WORK BEING DONE ON THIS PROJECT. | | PER WPB AMEND TO FBC 107.2.1 | | | | 2. PLEASE INDICATE LEVEL OF ALTERATION ON THE PLAN. PER | | FBC EX CH 5 | | | | 3. PLEASE PROVIDE A COST BREAK DOWN TO SHOW COMPLIANCE | | WITH | | | | FBC ACC 202.4 ALTERATIONS AFFECTING PRIMARY FUNCTION | | AREAS.IN ADDITION TO THE REQUIREMENTS OF 202.3, AN | | ALTERATION THAT AFFECTS OR COULD AFFECT THE USABILITY | | OF OR ACCESS TO AN AREA CONTAINING A PRIMARY FUNCTION | | SHALL BE MADE SO AS TO ENSURE THAT, TO THE MAXIMUM | | EXTENT FEASIBLE, THE PATH OF TRAVEL TO THE ALTERED | | AREA, INCLUDING THE REST ROOMS, TELEPHONES, AND | | DRINKING FOUNTAINS SERVING THE ALTERED AREA, ARE | | READILY ACCESSIBLE TO AND USABLE BY INDIVIDUALS WITH | | DISABILITIES, UNLESS SUCH ALTERATIONS ARE | | DISPROPORTIONATE TO THE OVERALL ALTERATIONS IN TERMS OF | | COST | | | | FBC ACC 202.4.1 DISPROPORTIONATE COST. | | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF | | TRAVEL TO THE ALTERED AREA WILL BE DEEMED | | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE | | COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE | | PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS | | EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF | | TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING | | AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING | | RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, | | ENLARGING TOILET STALLS, INSULATING PIPES, OR | | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS | | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH | | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, | | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT | | TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING | | AN INACCESSIBLE DRINKING FOUNTAIN. | | | | | | FBC ACC 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. | | WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH | | OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS | | DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, | | THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE | | EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING | | DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE | | ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE | | ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE | | FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN | | ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST | | ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX | | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE | | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | PER FBC EX 705 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-10-16 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2018-10-15 |
Time |
|
Sent To |
|
|
Notes |
2018-10-16 15:26:32 | LANDSCAPE INSPECTION REQUIRED PRIOR TO CERTIFICATE OF | | OCCUPANCY TO DETERMINE IF THE EXISTING LANDSCAPING | | MATCHES THE 2009 LANDSCAPE PLAN, SUBMITTED WITH THE | | PERMIT APPLICATION. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-08-20 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-08-20 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2018-08-20 |
Time |
|
Sent To |
|
|
Notes |
2018-08-20 10:34:13 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) UPDATED, SIGNED AND SEALED SURVEY IS REQUIRED. | | SURVEY SUBMITTED WITH THE PERMIT APPLICATION IS A COPY | | AND IT IS OUTDATED. | | | | 2.) MISSING DATA IN THE SITE PLAN TABULAR (SHEET A-IA), | | INCLUDING THE LOT COVERAGE AND FLOOR AREA RATIO (FAR), | | ETC. | | | | 3.) HEIGHT DIMENSION MISSING FROM THE ELEVATIONS. | | | | 4.) SHOW SETBACK DISTANCE OF THE FUTURE A/C UNIT | | CONDENSER IN THE SITE PLAN. A/C UNIT CONDENSER CANNOT | | ENCROACH MORE THAN 4 FT. INTO A SETBACK. [ZLDR | | S.94-305(A)] | | | | 5.) THE VALUE OF THE CONSTRUCTION ($65,000.00) EXCEEDS | | 50% OF THE STRUCTURE'S VALUE ($62,661.00) ACCORDING TO | | THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | | | NOTES: | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: NC | | | | | | |
|
|
|