Plan Review Details - Permit 18070720
Plan Review Stops For Permit 18070720 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
N |
Date |
2018-08-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-30 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
rsklarew |
Date |
2018-08-15 |
Time |
12:19 |
Sent To |
|
|
Notes |
2018-07-30 09:32:46 | ****CORRECTIONS**** | | REVISED 7/31 | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1609, A NEW NOA WAS INCLUDED, INSULFOAM EPS & | | R-TECH EPS ROOF INSULATION. I AM UNABLE TO LOCATE THIS | | IN THE ASSEMBLY SELECTED IN THE FIBERTITE SINGLE PLY | | ROOF SYSTEM OVER RECOVER DECKS NOA. | | | | FBC 107, MARK PRODUCT APPROVAL TO INDICATE COMPONENTS | | PROPOSED IN THE ASSEMBLY SELECTED. | | | | 2. THE NOA FOR THE 05-1026.08 IS SUPERSEDED. PROVIDE | | CURRENT PRODUCT APPROVALS AND VERIFY THAT ENGINEERING | | DOES NOT NEED TO BE REVISED PRIOR TO RESUBMITTING. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-07-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-18 |
Time |
18:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-18 |
Time |
18:43 |
Sent To |
|
|
Notes |
2018-07-18 18:46:46 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FBC 107: | | | | 1. THE MASTER FOR THIS PROJECT HAS NOT YET BEEN | | SUBMITTED AS THE CODE CHANGED ON 12/31/2017. IF YOU | | WANT THIS PROJECT MASTERED, SUBMIT A "MASTER" PERMIT | | APPLICATION WITH ORIGINAL ENGINEERING AND PRODUCT | | APPROVALS. YOUR PERMIT APPLICATIONS SHOULD INCLUDE THE | | MASTER NUMBER. | | | | 2. IF THIS PROJECT IS NOT GOING TO BE MASTERED, SUBMIT | | TWO PRODUCT APPROVALS AND TWO ORIGINAL ENGINEERING. | | ONLY ONE SET OF DOCUMENTS WAS SUBMITTED. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-07-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-30 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-23 |
Time |
13:51 |
Sent To |
|
|
Notes |
2018-07-23 13:51:50 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-07-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-18 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-17 |
Time |
09:14 |
Sent To |
|
|
Notes |
|
|
|