Plan Review Details - Permit 18070655
Plan Review Stops For Permit 18070655 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-09-21 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-09-21 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-09-21 |
Time |
14:51 |
Sent To |
|
|
Notes |
2018-09-21 14:54:22 | ADJUST FEE VALUE FOR BUILDING AND ELECTRICAL COSTS | | COMBINED TO $14,400.00 | | MECHANICAL PERMIT WILL BE SEPARATE PERMIT AND THE VALUE | | IS EXCLUDED FORM THIS PERMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-07-31 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-07-31 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-07-31 |
Time |
10:58 |
Sent To |
|
|
Notes |
2018-07-31 11:44:51 | ****CORRECTIONS**** | | W.P.B. PERMIT: 18070655 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC EB = FBC EXISTING BUILDING | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. [FBC 109]PROVIDE COPY OF PROPOSAL WITH CONTRACTOR TO | | SHOW WORK VALUE EQUAL TO THE AMOUNT SHOWN ON PERMIT | | APPLICATION, OR ADJUST VALUE TO MATCH ACTUAL COST OF | | WORK. VALUE WILL BE FOR ALL WORK INCLUDING MECHANICAL | | AND ELECTRICAL. | | | | 2. [FBC 107.2.5]HEAD AND SILL DETAIL ARE FOR WOOD FRAME | | 2X6. PROVIDE DETAILS FOR SITE CONDITIONS(2X4 | | CONSTRUCTION AND MASONRY CONSTRUCTION). | | ALSO, BUCK DETAILS FOR BOTH CONDITIONS. | | | | 3. [FBC 107.2.5]PROVIDE INFILL DETAILS IF OPENINGS ARE | | BEING ADJUSTED. | | | | 4. [FBC 107.2.5]THE WINDOW PRODUCT APPROVAL ALLOWS FOR | | OPENINGS UP TO 52". | | PLEASE ADJUST WINDOWS TO MEET PRODUCT APPROVAL. I WOULD | | SUGGEST A WINDOW SCHEDULE. SELECT WINDOW TYPE FOR WALL | | TYPE (NAIL FIN OR THROUGH FRAME, IF WINDOW IS EGRESS, | | PROVIDE BOTH R.O. AND WINDOW SIZE FOR EACH | | WINDOW.(WINDOW SCHEDULE) | | | | 5. [FBC ENERGY R503.1.1.1]WHERE SOME OR ALL OF AN | | EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW | | FENESTRATION PRODUCT, INCLUDING SASH AND GLAZING, THE | | REPLACEMENT FENESTRATION UNIT SHALL MEET THE APPLICABLE | | REQUIREMENTS FOR U-FACTOR AND SHGC AS PROVIDED IN TABLE | | R402.1.2. | | YOUR WINDOWS SHOULD HAVE U-FACTOR OF 0.75 AND SHGC OF | | 0.25THE WINDOWS SHOULD COME WITH STICKERS ON THEM. | | LEAVE THE STICKERS ON WINDOWS UNTIL YOU PASS | | INSPECTION. | | | | 6. [FBC R317.1] 5.WOOD SIDING, SHEATHING AND WALL | | FRAMING ON THE EXTERIOR OF A BUILDING HAVING A | | CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE | | GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED | | VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO | | SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE | | WEATHER. | | | | 7. WHEN RE-SUBMITTING HAVE THE PERMIT APPLICATION | | NOTARIZED. | | | | NOTE: | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | OF MATERIALS REQUESTED. | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-26 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-26 |
Time |
13:24 |
Sent To |
|
|
Notes |
2018-09-26 13:24:28 | PROVISO ADDED TO PLAN. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-25 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-25 |
Time |
08:58 |
Sent To |
I |
|
Notes |
2018-09-25 08:57:53 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC | | 109.3 (COPY OF CONTRACT NOT PROVIDED.) | | 2. CORRECTED. | | 3. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902 (NOT CORRECTED, NOTE STILL | | STATES BEDROOMS TO BE AFCI, PANEL SCHEDULE DOES NOT | | SHOW ALL AREAS REQUIRED.) | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | NEC 110.9, 110.10; FBC RE E3606.3 (THIS IS REQUIRED IN | | RESIDENTIAL INSTALLATIONS, WHICH IS WHY IT IS LISTED IN | | THE FBC RESIDENTIAL R3606.3. PROVIDE AS REQUESTED.) | | 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 (NOTE NOT PROVIDED.) | | 6. CORRECTED. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-10 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-10 |
Time |
11:26 |
Sent To |
I |
|
Notes |
2018-08-10 11:26:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC | | 109.3 | | 2. SCOPE OF WORK STATES ALL NEW WIRING. PLAN MUST SHOW | | EACH LOCATION OF RECEPTACLES AND LIGHTING REQUIRED BY | | CODE. APARTMENT 738 DOES NOT SHOW THIS. PROVIDE | | CORRECTION. NEC 210.52; FBC RE E3901.2.1 | | 3. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902 | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | NEC 110.9, 110.10; FBC RE E3606.3 | | 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 | | 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-09-25 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-09-11 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-08-10 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-07-16 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2018-08-06 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-08-06 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-08-06 |
Time |
13:11 |
Sent To |
|
|
Notes |
2018-08-06 13:12:40 | MECHANICAL CONTRACTOR TO PULL PERMIT FOR NEW A/C AND | | DUCTWORK | | | | CHRIS MONTELLO | | 561-805-6733 | | [email protected] |
|
|
|