Plan Review Details - Permit 18070222
Plan Review Stops For Permit 18070222
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-14 Cont ID  
Sent By cthroop Date 2018-07-14 Time 10:15 Rev Time 0.00
Received By cthroop Date 2018-07-14 Time 10:15 Sent To  
Notes
2018-07-14 10:20:38BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN.
 FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 2. PROVIDE ATTACHMENT DETAIL TO STRUCTURE. BASED ON
 DESIGN PRESSURES.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 3. PERSON RESONSIBLE FOR DESIGN TO PRINT NAME AND SIGN
 PLAN.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5) AND F.S. 481.229.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-14 Cont ID  
Sent By cthroop Date 2018-07-14 Time 10:21 Rev Time 0.00
Received By cthroop Date 2018-07-05 Time 14:06 Sent To I
Notes
2018-07-06 14:06:40ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status F Date 2018-07-10 Cont ID  
Sent By elevesqu Date 2018-07-10 Time 14:15 Rev Time 0.00
Received By elevesqu Date 2018-07-10 Time 14:13 Sent To B
Notes
2018-07-10 14:15:08PLEASE INCLUDE DIMENSIONS INCLUDING SIGN HEIGHT, WIDTH,
 VERTICAL CLEARANCE FROM SIDEWALK, AND DIMENSION FROM
 ENDGE OF BUILDING TO FURTHEST EDGE OF SIGN.
  
 SIGN CANNOT EXCEED THREE FEET IN HEIGHT, CANNOT EXTEND
 MORE THAN FOUR FEET FROM BUILDING (TO EDGE OF SIGN),
 VERTICAL CLEARANCE MUST BE EIGHT FEET.
  
 ANY QUESTIONS PLEASE CALL LIZ LEVESQUE 561 822 1426