Plan Review Details - Permit 18061356
Plan Review Stops For Permit 18061356
Review Stop E ELECTRICAL
Rev No 1 Status N Date 2018-07-09 Cont ID  
Sent By fgiaquin Date 2018-07-09 Time 06:41 Rev Time 0.00
Received By fgiaquin Date 2018-07-09 Time 06:33 Sent To G
Notes
2018-07-09 06:39:05ELECTRICAL PERMIT REQUIRED. NO ELECTRICAL WORK REVIEWED
 OR APPROVED. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED
 AND SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE
 ELECTRICAL CONTRACTOR QUALIFIER. IFS 471.003(2)(H);
 471.025; WPB FBC 107.2.1, 107.3.5

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2018-08-08 Cont ID  
Sent By lcrespo Date 2018-08-08 Time 17:02 Rev Time 0.00
Received By lcrespo Date 2018-08-08 Time 16:31 Sent To  
Notes
2018-08-08 17:03:3308/08/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING/GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-07-10 Cont ID  
Sent By thunt Date 2018-07-10 Time 15:39 Rev Time 0.00
Received By thunt Date 2018-07-10 Time 15:39 Sent To  
Notes
2018-07-10 15:47:4607/10/2018 1ST GAS REVIEW**DENIED**
  
 A SEPERATE PLUMBING PERMIT IS REQUIRED.
  
 1) VALUE. VALUE SEEMS LOW AND THE TANKLESS MUST BE
 INCLUDED IN YOUR COST. PROVIDE A BONA FIDA SIGNED
 CONTRACT. WPB AMEND TO THE FBC 109.3
  
 2) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1.
  
 3) INDICATE ON THE PLAN IF THE TANKLESS WATER HEATER IS
 THE ONLY GAS APPLIANCE ON THIS SYSTEM? IF NOT, SUBMIT A
 COMPLETE GAS RISER SHOWING ALL PIPE SIZES, TYPE OF
 PIPE, THE DEVELOPED LENGTH TO THE FURTHEST GAS OUTLET,
 THE BTU LOAD OF EACH APPLIANCE, THE PSI OF THE SYSTEM,
 THE TYPE OF GAS AND THE TOTAL BTU LOAD ON THE SYSTEM.
 THESE REQUIREMENTS ALSO APPLY TO A NEW GAS SYSTEM.
  
 4) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE
 LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION
 AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN
 RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER
 HEATER SHALL COMPLY WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND
 DRAWN. WPB AMEND. TO FBC SEC. 107.2.1
  
 5) ISOMETRIC IS SHOWING TANKLESS AS 199,000BTU'S BUT
 SPEC SHEET PROVIDE ONLY LIST MAX @ 157,000BTU'S. PLEASE
 CLARIFY.
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-08 Cont ID  
Sent By lcrespo Date 2018-08-08 Time 17:02 Rev Time 0.00
Received By lcrespo Date 2018-08-07 Time 13:53 Sent To  
Notes
2018-08-08 13:53:46RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-10 Cont ID  
Sent By thunt Date 2018-07-10 Time 15:47 Rev Time 0.00
Received By thunt Date 2018-06-28 Time 15:40 Sent To  
Notes
2018-06-28 15:40:53PLUMB <5K