Plan Review Stops For Permit 18061189 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-08-21 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-08-21 |
Time |
11:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-08-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-08-11 |
Time |
19:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-08-11 |
Time |
19:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-09-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-09-01 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-09-01 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-08-06 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-06 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-06 |
Time |
08:43 |
Sent To |
|
|
Notes |
2018-08-06 08:43:20 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED | | TO BEAR THE NAME AND BE SIGNED AND SEALED BY THE PERSON | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. WPB FBC | | 107.1, 107.2; FS 471, 481 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-07-11 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-07-11 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-07-11 |
Time |
09:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-09-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-09-01 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-08-20 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-08-13 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-07-06 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-08-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-08-29 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-08-29 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-07-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-07-26 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-07-26 |
Time |
12:30 |
Sent To |
|
|
Notes |
2018-07-26 12:35:52 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18061189 | | 7/26/18 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M1.1: SHOW THE LOCATIONS OF KEY NOTES #2 & 4 | | ON THE FLOOR PLAN DRAWING. | | | | 2) THE MECHANICAL PLANS SHALL BE ELECTRONICALLY SIGNED | | AND SEALED BY THE ENGINEER OF RECORD- SECTION | | 61G15-23.005 FAC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-09-01 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-09-01 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-09-01 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-08-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-08-13 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-08-13 |
Time |
14:42 |
Sent To |
|
|
Notes |
2018-08-13 16:18:09 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. THE DIGITAL SIGNATURES ARE MISSING ON PLUMBING PAGES | | THEY SHALL COMPLY WITH FAC 61G15-23.003 | | | | 2. THE INSIDE WIDTH OF THE SHOWER IS SHOWN AT 3'-2" THE | | CODE REQUIRES 36" EXACT. PER FBC ACC 608.2.3 | | | | 3. IN ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS, GRAB | | BARS SHALL BE PROVIDED ON THE BACK WALL AND THE SIDE | | WALL FARTHEST FROM THE COMPARTMENT ENTRY. GRAB BARS | | SHALL NOT BE PROVIDED ABOVE THE SEAT. GRAB BARS SHALL | | BE INSTALLED 6 INCHES (150 MM) MAXIMUM FROM ADJACENT | | WALLS. FBC ACC 608.3.3 | | | | 4. THE CLEAR FLOOR SPACE FOR LAV SHALL COMPLY WITH FBC | | ACC 606.2 | | | | 5. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | THE CENTERLINE OF THE DISPENSER. FBC ACC 604.7 | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-08-21 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-08-21 |
Time |
11:35 |
Sent To |
|
|
Notes |
2018-08-21 11:36:14 | A, MEP SHEETS OK | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2018-08-06 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-06 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-06 |
Time |
13:08 |
Sent To |
|
|
Notes |
2018-08-11 18:55:25 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | A SHEETS ARE OK | | MEP SHEETS ARE NOT DIGITALLY SIGNED & SEALED, FS471. | | | | | 2018-08-06 13:08:58 | SEE ELECTRICAL REVIEW. |
|
|