Plan Review Details - Permit 18061127
Plan Review Stops For Permit 18061127
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-08-08 Cont ID  
Sent By dbattles Date 2018-08-08 Time 14:28 Rev Time 0.00
Received By dbattles Date 2018-08-08 Time 14:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-03 Cont ID  
Sent By dbattles Date 2018-08-03 Time 10:00 Rev Time 0.00
Received By dbattles Date 2018-08-03 Time 10:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-26 Cont ID  
Sent By dbattles Date 2018-07-26 Time 11:50 Rev Time 0.00
Received By dbattles Date 2018-07-25 Time 15:02 Sent To  
Notes
2018-07-26 11:50:51****CORRECTIONS****
 W.P.B. PERMIT: 18061127
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. SOIL REPORT DIDN'T UPLOAD IN PROJECT DOX. PLEASE
 UPLOAD SOIL REPORT IN SUPPORTING DOCS FOLDER.
  
 2. [FBC 107.3.5.3] PROVIDE SEDIMENT CONTROL PLAN TO
 KEEP CONSTRUCTION DEBRIS FROM ENTERING ADJACENT
 PROPERTIES AND STORM DRAINS.
  
 3. OWNER OR OWNERS AGENT TO SIGN ENERGY CALCULATIONS.
  
 4. [FBC R608.8]PROVIDE MINIMUM BEARING ON LINTEL
 SCHEDULE. PROVIDE LINTEL DOCUMENTATION FOR SAFE
 LOADING.
  
 5. [FBC R806.3]IF BLOWN IN INSULATION IS BEING USED,
 HOW WILL YOU PREVENT IT FROM BLOCKING CROSS
 VENTILLATION? SHOW/EXPLAIN ON PLANS A-2.0 WHERE
 INSULATION IS CALLED OUT ON WALL SECTION
 INSULATION WIND BAFFLES, VENTING CHUTES, RAFTER VENTS
 OR INSULATION BAFFLES. KEEP THE BLOWN IN FROM GOING
 INTO THE EAVES.
 6. [FBC R107.3.5.3]CONTINUE WALL SECTION ON A-2.0
 THROUGH ROOF.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-08-03 Cont ID  
Sent By jleahy Date 2018-08-03 Time 14:13 Rev Time 0.00
Received By jleahy Date 2018-08-03 Time 14:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-07-08 Cont ID  
Sent By jpearson Date 2018-07-08 Time 10:08 Rev Time 0.00
Received By jpearson Date 2018-07-08 Time 09:27 Sent To  
Notes
2018-07-08 10:08:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED
 TO BEAR THE NAME AND BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. WPB FBC
 107.1, 107.2; FS 471, 481
 2. NOTE 5 OF THE ELECTRICAL NOTES FOR AFCI PROTECTION
 DOES NOT INCLUDE ALL AREAS REQUIRED PER CODE. PER CODE,
 ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE,
 15- AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. PROVIDE CORRECTION TO NOTE.
 NEC 210.12; FBC RE E3902.16
 3. LAUNDRY CIRCUIT SHOULD BE CALCULATED AT 1.5 KW, NOT
 1.0 AS SHOWN ON PLAN. PROVIDE CORRECTION. NEC 220.82;
 FBC RE E3602.2
 4. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 5. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
 6. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED
 GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL
 SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON
 THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE
 LEVEL ACCESS. PROVIDE CORRECTION FOR SHED. NEC
 210.70(A)(2)(B), FBC RE E3903.3
 7. PLAN STATES THERE IS A GAS RANGE, BUT THE LOAD
 CALCULATION SHOWS AN ELECTRIC RANGE. CORRECT
 DISCREPANCY. IF THERE ARE ANY GAS APPLIANCES, PROVIDE
 CARBON MONOXIDE DETECTOR WITHIN 10 FEET OF ANY ROOM
 USED FOR SLEEPING PURPOSE. WPB FBC 107.2.1; FBC RE
 R15.1
 8. PLAN INCORRECTLY LABELS THE FEEDER TO INTERIOR PANEL
 AS 3 - #1 THHN WITH BOND. WHILE THIS ACCOMPLISHES THE
 BOND FUNCTION REQUIRED, IT ALSO ACCOMPLISHES THE
 GROUNDING REQUIRED AND SHOULD THEREFORE BE LABELED AS
 THE EQUIPMENT GROUNDING CONDUCTOR. THIS EGC SHOULD BE
 SIZED PER NEC 250.122 AND/OR FBC RE E3908.8. PROVIDE
 CORRECT NOMENCLATURE AND PROVIDE SIZE PER CODE. NEC
 250.122; FBC RE E3704.6
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-08-08 Cont ID  
Sent By dbattles Date 2018-08-08 Time 14:28 Rev Time 0.00
Received By dbattles Date 2018-08-07 Time 16:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-07 Cont ID  
Sent By gjohnson Date 2018-08-07 Time 08:41 Rev Time 0.00
Received By gjohnson Date 2018-08-02 Time 13:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-02 Cont ID  
Sent By lmarchan Date 2018-08-02 Time 09:29 Rev Time 0.00
Received By lmarchan Date 2018-07-02 Time 15:47 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2018-08-03 Cont ID  
Sent By dbattles Date 2018-08-03 Time 10:01 Rev Time 0.00
Received By dbattles Date 2018-08-03 Time 10:01 Sent To  
Notes
2018-08-03 10:01:45PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-07-31 Cont ID  
Sent By hmoser Date 2018-07-31 Time 11:33 Rev Time 0.00
Received By hmoser Date 2018-07-31 Time 11:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-08-07 Cont ID  
Sent By gjohnson Date 2018-08-07 Time 08:39 Rev Time 0.00
Received By gjohnson Date 2018-08-07 Time 08:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By gjohnson Date 2018-07-30 Time 17:04 Rev Time 0.00
Received By gjohnson Date 2018-07-30 Time 17:04 Sent To  
Notes
2018-07-30 17:31:381ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE WASHING MACHINE SHALL CONNECT SEPARATELY TO THE
 BUILDING DRAIN IT CANNOT DISCHARGE THROUGH THE BATHROOM
 GROUP. PER FBC RES P3108.1
  
 2. THE TUB AND TOILET IN BATH #2 ARE NOT VENTED AND THE
 SHOWER IN MASTER BATH IS NOT VENTED SHALL BE VENTED
 BEFORE CONNECTING TO THE BUILDING DRAIN. PER FBC RES
 P3101.2.1, P3108.1
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2018-07-26 Cont ID  
Sent By dbattles Date 2018-07-26 Time 11:51 Rev Time 0.00
Received By dbattles Date 2018-07-26 Time 11:51 Sent To  
Notes
2018-07-26 11:52:22PRODUCT APPROVAL REVIEWED FOR SINGLE ROOF.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2018-08-08 Cont ID  
Sent By dbattles Date 2018-08-08 Time 14:27 Rev Time 0.00
Received By dbattles Date 2018-08-08 Time 14:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-08-03 Cont ID  
Sent By dbattles Date 2018-08-03 Time 13:21 Rev Time 0.00
Received By dbattles Date 2018-08-03 Time 13:21 Sent To  
Notes
2018-08-07 08:46:258/7/18 DIG SIG ON PLUMB IS OK/GPJ
2018-08-03 13:24:31THE FOLLOWING SHEETS HAVE NO DIGITAL SIGNATURE:
 AS-1
 A-1.0
 A-2.0
 A-3.0
 S-1.0
 L-1.0
 M-1.0
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-08-03 Cont ID  
Sent By mcruz Date 2018-08-03 Time 14:11 Rev Time 0.00
Received By mcruz Date 2018-08-03 Time 13:52 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-07-26 Cont ID  
Sent By MC Date 2018-07-26 Time 17:06 Rev Time 0.00
Received By mcruz Date 2018-07-26 Time 17:04 Sent To PC
Notes
2018-07-26 17:06:23ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION
 PERMIT. SHOWING THE FOLLOWING:
 RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
 SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
 O GROSS LOT SQUARE FOOTAGE MINUS
 O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
 O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE
 OR PORTION THEREOF
 O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE
 OR PORTION THEREOF
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]