Plan Review Details - Permit 18061121
Plan Review Stops For Permit 18061121 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-07-31 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-07-12 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-07-12 |
Time |
11:51 |
Sent To |
P |
|
Notes |
2018-07-12 11:56:00 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PLANS NOW SHOW A TENNANT BUILD OUT. | | | | PAGE E3.1 AND E3.2 SHOW NEW TENNANT | | | | PLANS NEED TO BE SIGNED AND SEALED BY PERSON OF RECORD. | | | | RISER DIAGRAM MISSING | | | | PANEL SCHEDULES MISSING | | | | NO ADDED VALUE FOR THIS WORK WAS ADDED TO THE PERMIT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-08-01 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-07-03 |
Time |
08:03 |
Sent To |
|
|
Notes |
2018-07-06 08:03:57 | REVISION ROUTED TO JLEAHY |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-08-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-07-31 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-07-31 |
Time |
15:32 |
Sent To |
|
|
Notes |
2018-07-31 15:44:14 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: PROVISO TO BE CORRECTED UNDER MAIN | | PERMIT #18040104 | | | | | | 1. THE NEW 6" SANITARY FROM THE UPPER FLOORS CAN NOT | | DISCHARGE TO THE SUMP PIT IN THE BASEMENT IT SHALL | | CONNECT TO THE GRAVITY SYSTEM CONNECTED TO THE CITY | | TAP. PER FBC PL 712.1 | | | | 2. THE CONDENSATE LINES FROM THE AC UNITS SHALL NOT | | DISCHARGE TO THE SANITARY SYSTEM IT APPEARS TO BE | | DISCHARGING INTO THE SUMP PIT. PER WEST PALM BEACH CITY | | ORDINANCE SEC. 90-126.(5) | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
|