Plan Review Details - Permit 18061114
Plan Review Stops For Permit 18061114 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-20 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-20 |
Time |
12:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-07-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-19 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-19 |
Time |
07:48 |
Sent To |
|
|
Notes |
2018-07-19 17:09:03 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | FBC B 1609 | | | | 1. THE PRODUCT APPROVAL DOES NOT HAVE PROVISION FOR | | ENHANCED FASTENING | | 2. THE ENHANCED FASTENING LETTER FROM THE ENGINEER DOES | | NOT ADDRESS THE PANEL SEAM REQUIREMENT, WHICH AFFECTS | | UPLIFT | | 3. ENHANCED FASTENING ENGINEERING IS FOR ZONES 2 AND 3 | | PRESSURES (-64, -94.6); -74.9 AND -125.9 ARE REQUIRED | | 4. IF THE BUILDING OFFICIAL ELECTS TO ALLOW FOR YOU TO | | UTILIZE ENHANCED FASTENING, HOW WILL YOU DESIGNATE THE | | DIFFERENT ZONES FOR THE INSPECTOR? THIS METHOD OF | | INSTALLATION IS TYPICALLY DONE ON FLAT DECKS BASE | | SHEET; THE BASE SHEET CAN BE MARKED/CHALK LINED. HOW | | WILL YOU ACCOMPLISH THIS ON THE METAL ROOF? | | 5. ENGINEERING IS TO BE SIGNED, SEALED, DATED | | ORIGINALS. WE SUGGEST THAT, IF YOU USE AN ENGINEER WHO | | HAS A DIGITAL SEAL, YOU SUBMIT THE APPLICATION | | DIGITALLY. FOR THIS ONE PERMIT, IF IT IS DETERMINED | | THAT ENGINEERING IS ACCEPTABLE (BY B.O.), YOU MAY EMAIL | | THE ORIGINAL TO ME AFTER THE BUILDING REVIEW IS PASSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-07 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-07 |
Time |
14:20 |
Sent To |
|
|
Notes |
2018-07-07 14:37:16 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | COMMENTS FROM PREVIOUS LIST: | | | | 1. SEE SHEET S4.00; THE ASSEMBLY SELECTED DOES NOT | | APPEARS TO MEET THE DESIGN PRESSURE REQUIREMENTS | | SPECIFIED BY THE ENGINEER, FBC B 1609. | | | | 2. FBC 107, PRODUCT APPROVALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. | | | | 2ND REVIEW, COMMENTS NOT ADDRESSED. | | | | SEE SHEET S4.00. ENGINEER SPECIFIES PRESSURES AS | | FOLLOWS: | | | | ZONE 1 -30.6 | | ZONE 2 -64.0 | | ZONE 3 -94.6 | | | | THE METAL ROOF ASSEMBLY SELECTED HAS A DP LIMITATION OF | | -60 PSF. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-06-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-27 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-27 |
Time |
17:48 |
Sent To |
|
|
Notes |
2018-06-27 17:50:32 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. SEE SHEET S4.00; THE ASSEMBLY SELECTED DOES NOT | | APPEARS TO MEET THE DESIGN PRESSURE REQUIREMENTS | | SPECIFIED BY THE ENGINEER, FBC B 1609. | | | | 2. FBC 107, PRODUCT APPROVALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-07-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-19 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-17 |
Time |
13:34 |
Sent To |
|
|
Notes |
2018-07-18 13:34:38 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-07 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-03 |
Time |
15:52 |
Sent To |
|
|
Notes |
2018-07-05 15:53:02 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-06-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-27 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-22 |
Time |
09:56 |
Sent To |
|
|
Notes |
|
|
|