Plan Review Stops For Permit 18061061 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-11-13 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-11-13 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-10-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-10-16 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-10-11 |
Time |
16:52 |
Sent To |
|
|
Notes |
2018-10-16 13:34:16 | DB SPOKE WITH NICOLE FROM BEACON CONST. | | PENDING CONTRACTOR RESPONSE TO PRODUCT APPROVALS. | | 5' SETBACK REQUIRED FOR SHED. | | IT WAS APPROVED AS REMODEL WHERE THE STRUCTURE WAS NOT | | BEING COMPLETLY DEMOLISHED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-07-20 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-07-20 |
Time |
12:45 |
Sent To |
|
|
Notes |
2018-07-20 12:47:08 | ****CORRECTIONS**** | | W.P.B. PERMIT: 18061061 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. [FBC 107.3.5.3]ADD THE CONSTRUCTION TYPE TO PROJECT | | DATA. | | | | 2. [FBC R107.2.5]SHEET A-100 REFERS TO SHEET A101 FOR | | EXTENT OF DEMO. PLEASE PROVIDE DEMO SHEET A-101. | | IS THE EXISTING STRUCTURE BEING COMPLETLY DEMOED? | | SEPARATE PERMIT FOR DEMO WILL BE NEEDED. | | | | 3. [FBC 107.3.5.3]SECTION 1/S-201 DOESN'T MATCH WHAT | | THE ELEVATIONS SHOW. HOW DOES THE RAISED FLOOR WORK | | WITH SLAB ON GRADE AS SHOWN ON 1/S-210? | | | | 4. [FBC 107.3.5.3]HOW IS RAISING THE STRUCTURE 1'-9" | | ACHIEVED? SHOW DETAIL OF HOW EXISTING TIES INTO THE NEW | | FOUNDATION. | | | | 5. [FBC 107.3.5.3]IS ALL STUCCO BEING REPLACED? PROVIDE | | DETAIL OF MATERIALS/ATTACHMENT OF STUCCO TO WOOD | | FRAMING AND WHAT HAPPENS AT FOUNDATION. | | | | [FBC 107.3.4.1]DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL FOR | | REVIEW, AND THEN FORWARED TO THE BUILDING | | OFFICIAL INDICATING THAT THE DEFERRED SUBMITTAL | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | CONFORMANCE TO THE DESIGN. THE DEFERRED SUBMITTAL ITEMS | | SHALL NOT BE INSTALLED UNTIL THE DEFERRED SUBMITTAL | | DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. | | | | 6. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR WINDOWS | | AND DOORS, OR INDICATE THAT YOU WOULD LIKE THEM | | DEFFERED. | | | | 7. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR | | ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM DEFFERED. | | | | 8. [FBC R408.4]PROVIDE ACCESS TO THE UNDER FLOOR SPACE | | 18X24 MINIMUM. | | | | 9. [FBC 107.3.5.3]PROVIDE DETAIL OF HOW UNDER FLOOR | | VENTS WORK WITH THE FOUNDATION. | | | | 10. [FBC 107.3.5.3]UPDATE CODE REFERENCE TO CURRENT | | CODE ON SHEET S-200 WIND LOAD SCHEDULE. | | | | 11. [FBC R803.2.3.1]UPDATE SHEATHING FASTENING ON | | S-201. | | SHEATHING NAILS TO BE RING SHANK RSRS01(2 3/8 X 0.113) | | | | NOTE: | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | OF MATERIALS REQUESTED. | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-10-03 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-03 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-03 |
Time |
13:20 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-09-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-19 |
Time |
07:19 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-19 |
Time |
06:41 |
Sent To |
|
|
Notes |
2018-09-19 07:19:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. NOTE 1 DETAILING AFCI PROTECTION IS NOT CODE | | COMPLIANT. PER CODE, ALL BRANCH CIRCUITS THAT SUPPLY | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | PROTECTED. SOME AREAS REQUIRE GFCI AND AFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902.16 | | (NOT ADDRESSED.) | | 2. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 (NOT ADDRESSED.) | | | | NEW COMMENT: | | | | 3. NOTE 2 SPECIFIES NEC 2011 AS BASIS FOR DESIGN. THE | | NEC SPECIFIED FOR DESIGN IS NOT THE CURRENT CODE. | | PROVIDE CORRECTION. FBC PREFACE (ALSO SEE CURRENT CODES | | ABOVE) | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-07-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-07-17 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-07-17 |
Time |
05:52 |
Sent To |
|
|
Notes |
2018-07-17 13:43:43 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. NOTE 1 DETAILING AFCI PROTECTION IS NOT CODE | | COMPLIANT. PER CODE, ALL BRANCH CIRCUITS THAT SUPPLY | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | PROTECTED. SOME AREAS REQUIRE GFCI AND AFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902.16 | | 2. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-11-13 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-11-13 |
Time |
14:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-09-26 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-09-26 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2018-07-05 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-07-05 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-07-05 |
Time |
11:06 |
Sent To |
|
|
Notes |
2018-07-05 11:11:24 | PLANS JUST PRESENTED FOR DEMO/RECONSTRUCTION OF | | ACCESSORY STRUCTURE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-11-13 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-10-23 |
Time |
14:04 |
Sent To |
|
|
Notes |
2018-10-24 14:04:19 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-10-24 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-10-24 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-08-30 |
Time |
15:52 |
Sent To |
|
|
Notes |
2018-10-19 08:06:58 | PLANS ON D.B. DESK | 2018-08-31 15:53:26 | R12 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-08-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-08-07 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-06-21 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-07-30 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-07-30 |
Time |
14:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2018-08-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-08-07 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-08-07 |
Time |
14:04 |
Sent To |
|
|
Notes |
2018-08-07 14:08:18 | NO VIEW REQUIRED BECAUSE THERE ARE NO PLUMBING | | APERTURES IN THIS BUILDING. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-11-13 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-11-13 |
Time |
14:09 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-09-26 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-09-26 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-07-05 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-07-05 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-07-05 |
Time |
11:06 |
Sent To |
|
|
Notes |
|
|