Plan Review Details - Permit 18060876
Plan Review Stops For Permit 18060876 |
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-08-08 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-08-01 |
Time |
11:19 |
Sent To |
|
|
Notes |
2018-08-02 11:19:44 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-06-27 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-06-19 |
Time |
11:33 |
Sent To |
|
|
Notes |
2018-06-20 11:33:36 | ROUTED TO MECHANICAL INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-08-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-08-08 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-08-08 |
Time |
12:17 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-06-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-06-27 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-06-27 |
Time |
17:08 |
Sent To |
I |
|
Notes |
2018-06-27 17:54:48 | 1ST REVIEW FBC-2017 RESIDENTIAL MECHANICAL | | | | CODES IN EFFECT: | | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE A CLEARER PLAN PER SECTION 107.2.1.3 WPB. | | | | A) IDENTIFY ALL ROOMS AND SPACES ON THE PLANS. | | | | B) INDICATE ALL DUCT SIZES (SOME SUPPLY AND RETURN DUCT | | SIZES NOT SHOWN). | | | | C) PROVIDE RETURN AIR FROM THE GUEST BEDROOM. | | | | D) LABEL THE AIR HANDLER. | | | | E) SHOW THE SUPPLY CFMS AT EACH DIFFUSER | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
|