Plan Review Details - Permit 18060533
Plan Review Stops For Permit 18060533
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-06-27 Cont ID  
Sent By pvalenti Date 2018-06-27 Time 08:27 Rev Time 0.00
Received By pvalenti Date 2018-06-27 Time 08:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-06-16 Cont ID  
Sent By pvalenti Date 2018-06-16 Time 10:51 Rev Time  
Received By pvalenti Date   Time   Sent To  
Notes
2018-06-16 10:54:47****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, RESUBMIT THE "SCHEDULE FOR INSTALLATION
 OF OPENING PROTECTIVE DEVICES". PROVIDE ALL INFORMATION
 REQUIRED.
 WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE NOTE
 PAGE 13 OF 20, FACTORS APPLY DEPENDING ON SUBSTRATE.
 2. THE EDGE DISTANCE SHOWN ON THE CITY OF W.P.B.
 INSTALLATION SCHEDULE (2.25") DOES NOT MEET THE
 REQUIREMENTS OF SHEET 13 ANCHORING SCHEDULE.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-27 Cont ID  
Sent By pvalenti Date 2018-06-27 Time 08:28 Rev Time 0.00
Received By pvalenti Date 2018-06-25 Time 14:26 Sent To I
Notes
2018-06-26 14:26:26RESUB ROUTED TO PVALENTI

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-16 Cont ID  
Sent By pvalenti Date 2018-06-16 Time 10:56 Rev Time 0.00
Received By pvalenti Date 2018-06-16 Time 10:56 Sent To  
Notes
2018-06-13 11:07:12BLDG MISC 1