Plan Review Details - Permit 18060347
Plan Review Stops For Permit 18060347
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2018-08-21 Cont ID  
Sent By shill Date 2018-08-21 Time 14:19 Rev Time 0.00
Received By shill Date 2018-08-21 Time 14:19 Sent To  
Notes
2018-08-21 14:20:23OLD ADDRESS: 871 VILLAGE BL #603B
 NEW ADDRESS: 901 VILLAGE BL #700
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2018-08-21 Cont ID  
Sent By shill Date 2018-08-21 Time 12:23 Rev Time 0.00
Received By shill Date 2018-07-28 Time   Sent To  
Notes
2018-08-21 12:24:35FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL):
  
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-21 Cont ID  
Sent By shill Date 2018-08-21 Time 13:01 Rev Time 0.00
Received By shill Date 2018-08-21 Time 12:26 Sent To  
Notes
2018-08-21 13:01:51CHANGE OF OCCUPANCY - A2 TO B
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-06-30 Cont ID  
Sent By shill Date 2018-06-30 Time 11:49 Rev Time 0.00
Received By shill Date 2018-06-30 Time 11:49 Sent To  
Notes
2018-06-30 11:50:07****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED
 SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 2. SEE ELECTRICAL COMMENTS (ADDRESS, VALUE); APPLICABLE
 FOR BUILDING REVIEW.
  
 3. WHAT WAS THE PERMITTED OCCUPANCY CLASSIFICATION FOR
 THIS SPACE? IS THIS A CHANGE OF OCCUPANCY OR USE? IF
 YES, REVISE PLAN TO SHOW COMPLIANCE WITH REQUIREMENTS
 OF FBC EB CHAPTER 10 AND CONTACT PALM BEACH COUNTY
 IMPACT FEES, 561-233-5025 TO DETERMINE IF AN IMPACT FEE
 ASSESSMENT IS REQUIRED.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-07-27 Cont ID  
Sent By ppetty Date 2018-07-27 Time 15:03 Rev Time 0.00
Received By ppetty Date 2018-07-27 Time 15:03 Sent To  
Notes
2018-07-27 14:12:24CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: OK, SEE COMMENTS BELOW.
  
 1. CORRECTED
 2. CORRECTED
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-06-28 Cont ID  
Sent By jpearson Date 2018-06-28 Time 13:04 Rev Time 0.00
Received By jpearson Date 2018-06-28 Time 11:43 Sent To  
Notes
2018-06-28 13:04:25CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. THERE ARE ADDRESS ISSUES WITH THIS SUBMITTAL.
 ACCORDING TO MICHAEL ORIO, GIS SUPPORT SPECIALIST, THE
 ADDRESS OF 901 VILLAGE DOES NOT HAVE UNITS IN THE 600
 RANGE. ADDITIONALLY, LETTERS ARE NOT PERMITTED IN THE
 NUMERICAL PORTION OF THE ADDRESS. PROVIDE CORRECTED
 ADDRESS ON PLANS. MR ORIO CAN BE REACHED AT
 [email protected]. WPB FBC 107.2.1
 2. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC
 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-07-25 Cont ID  
Sent By scaldero Date 2018-07-25 Time 11:37 Rev Time 0.00
Received By scaldero Date 2018-07-25 Time 11:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-06-11 Cont ID  
Sent By scaldero Date 2018-06-11 Time 10:35 Rev Time 0.00
Received By scaldero Date 2018-06-11 Time 10:30 Sent To  
Notes
2018-06-11 10:35:14PERMIT # 18060347
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-09-01 Cont ID  
Sent By shill Date 2018-09-01 Time 11:46 Rev Time 0.00
Received By shill Date 2018-08-29 Time 14:30 Sent To  
Notes
2018-08-30 14:30:41RESUB ROUTED TO SHILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-21 Cont ID  
Sent By shill Date 2018-08-21 Time 13:01 Rev Time 0.00
Received By shill Date 2018-07-18 Time 14:57 Sent To  
Notes
2018-07-19 14:57:44B05

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-02 Cont ID  
Sent By lmarchan Date 2018-07-02 Time 11:44 Rev Time 0.00
Received By lmarchan Date 2018-06-07 Time 14:25 Sent To  
Notes
2018-06-08 14:26:03B16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-09-01 Cont ID  
Sent By shill Date 2018-09-01 Time 11:46 Rev Time 0.00
Received By shill Date 2018-09-01 Time 11:46 Sent To  
Notes
2018-09-01 11:46:38CHANGE OF OCCUPANCY FROM A2 TO B
 $0 DUE; PLAN STAMPED BY PALM BEACH COUNTY
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-06-30 Cont ID  
Sent By shill Date 2018-06-30 Time 11:51 Rev Time 0.00
Received By shill Date 2018-06-30 Time 11:51 Sent To  
Notes
2018-06-30 11:52:04SEE BUILDING REVIEW
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-08-24 Cont ID  
Sent By ccole Date 2018-08-24 Time 08:35 Rev Time 0.00
Received By ccole Date 2018-08-14 Time 08:35 Sent To I
Notes
2018-08-14 09:00:21PLAN NOTE:
  
 THE ENGINEER OF RECORD PROVIDED A SIGNED AND SEALED
 LETTER CERTIFYING THE LASH STUDIO WOULD NOT REQUIRE AN
 EXHAUST VENTILATION SYSTEM
 BECAUSE THE EYE LASH APPLICATION PROCEDURE DOES NOT
 PRODUCE ANY HARMFUL FUMES OR ODORS IN THE TENANT SPACE.
 ENGINEER'S LETTER IN PERMIT FILE.
  
 MECHANICAL APPROVED
 CCOLE 8/24/18

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-06-20 Cont ID  
Sent By ccole Date 2018-06-20 Time 14:45 Rev Time 0.00
Received By ccole Date 2018-06-20 Time 14:45 Sent To  
Notes
2018-06-20 16:10:301ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18060347
 6/20/18
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) REFER TO TABLE 403.3.1.1 FBC M: AN EXHAUST
 VENTILATION SYSTEM WITH A RATE OF 0.60 CFMS PER SQ. FT.
 IS REQUIRED FOR THE BEAUTY SALON. PLEASE NOTE THAT AIR
 FROM THE SALON SPACE CANNOT BE RECIRCULATED TO OTHER
 ROOMS AND SPACES PER FOOTNOTE B.
  
 2) SHEET M-1: REFER TO TABLE 403.3.1.1 FBC M AND
 CORRECT THE OUTDOOR AIR CALCULATIONS FOR THE PLAN- 25
 PERSONS PER 1000 SQ. FT. AT 20 CFMS PER PERSON + 0.12
 CFMS PER SQ. FT.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-08-16 Cont ID  
Sent By gjohnson Date 2018-08-16 Time 14:07 Rev Time 0.00
Received By gjohnson Date 2018-08-16 Time 08:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-06-29 Cont ID  
Sent By gjohnson Date 2018-06-29 Time 08:22 Rev Time 0.00
Received By gjohnson Date 2018-06-28 Time 16:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2018-07-24 Cont ID  
Sent By eschneid Date 2018-07-24 Time 16:57 Rev Time 0.25
Received By eschneid Date 2018-07-24 Time 16:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-07-02 Cont ID  
Sent By eschneid Date 2018-07-02 Time 09:57 Rev Time 0.25
Received By eschneid Date 2018-06-26 Time 12:01 Sent To  
Notes
***NONE***