Plan Review Details - Permit 18060308
Plan Review Stops For Permit 18060308
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-12-12 Cont ID  
Sent By dbattles Date 2018-12-12 Time 11:09 Rev Time 0.00
Received By dbattles Date 2018-12-12 Time 11:09 Sent To  
Notes
2018-12-12 11:09:14PROVISOS:
 ANY WORK INVOLVING POST TENSION SYSTEM MODIFICATIONS,
 OR IF TENDONS ARE DAMAGED WILL REQUIRE SPECIAL
 INPECTOR. THE SPECIAL INSPECTOR WILL NEED TO BE
 APPROVED ANDUTILIZED FOR NEW WORK OR REPAIRS.
  
 PROVIDE SUBMITTAL FOR FLOORING TO INCLUDE:
 1.IMPACT INSULATION CLASS (IIC) NOT LESS THAN 50, OR
 NOT LESS THAN 45 IF FIELD TESTED
 2. SOUND TRANSMISSION CLASS (STC) NOT LESS THAN 50, OR
 NOT LESS THAN 45 IF FIELD TESTED
 3. FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX
  
 SEPARATE PERMIT FOR FIRE ALARM WORK.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-10-22 Cont ID  
Sent By dbattles Date 2018-10-22 Time 11:04 Rev Time 0.00
Received By dbattles Date 2018-10-16 Time 16:37 Sent To  
Notes
2018-10-22 11:04:37PROVISOS:
 ANY WORK INVOLVING POST TENSION SYSTEM MODIFICATIONS,
 OR IF TENDONS ARE DAMAGED WILL REQUIRE SPECIAL
 INPECTOR. THE SPECIAL INSPECTOR WILL NEED TO BE
 APPROVED ANDUTILIZED FOR NEW WORK OR REPAIRS.
  
 COMMENT REVIEW NUMBER ONE SUGGESTED THAT SEPARATE
 PERMIT BE APPLIED FOR EACH UNIT. THIS WAS NOT DONE, SO
 ALL UNITS WILL BE UNDER ONE PERMIT. WORK WILL NEED TO
 BE DONE AS ONE PROJECT.
  
 PROVIDE SUBMITTAL FOR FLOORING TO INCLUDE:
 1.IMPACT INSULATION CLASS (IIC) NOT LESS THAN 50, OR
 NOT LESS THAN 45 IF FIELD TESTED
 2. SOUND TRANSMISSION CLASS (STC) NOT LESS THAN 50, OR
 NOT LESS THAN 45 IF FIELD TESTED
 3. FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX
  
 SEPARATE PERMIT FOR FIRE ALARM WORK.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By jgomez Date 2018-07-26 Time 16:43 Rev Time 0.00
Received By jgomez Date 2018-07-24 Time 14:54 Sent To  
Notes
2018-07-26 16:43:24BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS
  
 1- THE PROPOSED WORK INVOLVES 3 SEPARATE FLOORS.
 PROVIDE A SEPARATE PERMIT APPLICATION FOR EACH FLOOR.
 CLEARLY IDENTIFY THE UNIT OF EACH WHERE ALTERATION IS
 GOING TO TAKE PLACE. NOTE: SAME PLANS MAY BE USED, BUT
 NEED A SEPARATE PERMIT APPLICATION FOR EACH UNIT FOR
 PROPER INSPECTIONS. SEC. 105.1 CITY AMENDMENTS.
  
 2- THIS IS A THRESHOLD BUILDING. SPECIAL INSPECTOR MAY
 BE REQUIRED FOR NEW FLOOR PENETRATIONS INTO EXISTING
 POST TENSIONED SLAB. LOCATION OF PT TENDONS AND
 REINFORCEMENT IN SLAB IS REQUIRED BEFORE CORE DRILLING.
 COORDINATE WITH KEN CONRAD (CHIEF BUILDING INSPECTOR)
 PRIOR TO ANY WORK. SEE CONTACT INFORMATION BELOW.
  
 KEN CONRAD
 CHIEF BUILDING INSPECTOR
 PHONE: 805-6666 EXT: 6666
 E-MAIL: [email protected]
  
 3- -SHEET A-121-NEW PLAN:
 A)IT LOOKS LIKE THE SLIDING DOORS FOR CLOSET IN
 SECONDARY BEDROOM DON'T COMPLY WITH THE 32" USABLE
 DOORS REQUIREMENT #3 OF FAIR HOUSING ACT. SEE PAGE 3.9
 AND PAGE 3.14 OF FAIR HOUSING ACT MANUAL. REVISE AS
 REQUIRED.
  
 B)PURPLE DASHED LINES SHOWN ON KITCHEN AND BATHROOMS
 USED TO ILLUSTRATE THE CLEAR FLOOR SPACE BY THE
 APPLIANCES ARE NOT CLEAR. CLEARLY SHOW THE CLEAR FLOOR
 SPACE IN FRONT OF EACH APPLIANCE. NOTE: CLEARLY SPECIFY
 IF THERE ARE CABINETS BELOW PLUMBING FIXTURES.
 COORDINATE WITH SHEET A-460. THE KITCHEN ISLAND HAVE
 CABINETS BELOW, THEREFORE,THERE IS NO KNEE SPACE BELOW
 THE COUNTER. CLEARLY SHOW THE CLEAR DIMENSION BETWEEN
 THE REFRIGERATOR AND THE KITCHEN ISLAND. SEE PAGE 7.6
 AND 7.7 OF FAIR HOUSING ACT MANUAL.
  
 C) CLEARLY IDENTIFY WHICH TYPE OF BATHROOMS TO BE USED.
 "A" OR "B". SEE PAGE 7.34 OF FAIR HOUSING ACT MANUAL
 FOR PROPER REVIEW COMPLIANCE. NOTE: IT LOOKS LIKE THERE
 MAY BE AN ISSUE WITH THE DOOR IN WATER CLOSET
 COMPARTMENT OF BATHROOM LOCATED IN THE MIDDLE OF THE
 APARTMENT. IT LOOKS LIKE THERE MAY BE CONFLICT WITH THE
 REQUIRED CLEAR FLOOR SPACE OUTSIDE THE SWING OF THE
 DOOR.
  
  
 D) IT LOOKS LIKE THE SHOWERS DON'T COMPLY WITH THE
 CLEAR FLOOR SPACE THAT NEEDS TO BE PARALLEL AND FLUSHED
 WITH THE CONTROL WALL. SEE PAGE 7.56 OF FAIR HOUSING
 ACT MANUAL. REVISE AS REQUIRED.
  
 4--SHEET G-100:
 A)REVISE PROJECT CODE ANALYSIS (SEC. 107.2.1 CITY
 AMENDMENTS):
 (1)PROVIDE CORRECT FLOORS TO MATCH PERMIT APPLICATION
 AND PLANS. WORK IS ON FLOORS 10 THRU 12 NOT 8 THRU 10.
 (NOTE: ALSO NEED A PERMIT APPLICATION FOR EACH FLOOR
 UNIT)
 (2)REVISE JURISDICTION CONTACT INFORMATION. CURRENT
 BUILDING OFFICIAL IS ROBERT BROWN NOT DOUG WISE. REVISE
 PHONE NUMBER AND E-MAIL AS WELL. NOTE: THIS IS NOT PALM
 BEACH COUNTY JURISDICTION. THIS IS THE CITY OF WEST
 PALM BEACH. PHONE NUMBER AND E-MAIL ADDRESS IS NOT
 REQUIRED.
  
 B) THE CURRENT CODE IS THE FBC, 6TH EDITION (2017)
 UPDATE ALL THE INFORMATION ON SHEET G-100 THAT IS
 REFERENCING THE 2014 CODE.
 CHAPTER 553 F.S.
  
 C) REVISE/CLARIFY BUILDING DATA. ACCORDING TO CITY
 RECORDS (PERMIT #95009927) 3RD AND 4TH FLOORS HAVE HAVE
 NURSING UNITS, 5TH AND 6TH FLOORS HAVE ASSISTED LIVING
 UNITS AND 8TH THRU 11TH FLOOR AND PENTHOUSE HAVE
 INDEPENDENT UNITS. FOR CLARIFICATION THE OCCUPANCY OF
 THIS BUILDING IS A MIXED USE OF NURSING HOME, ASSISTED
 LIVING FACILITY AND INDEPENDENT LIVING FACILITY FOR THE
 ELDERLY. UNITS ON FLOORS 10 THRU 12 ARE RESIDENTIAL
 (R2).
 SEC. 301.1 FBC.
  
 5- FLOORING UNDERLAYMENT SOUND INSULATION MATERIAL TO
 BE USED FOR CERAMIC TILE AND WOOD FLOORING(NOTE: THIS
 MAY BE SUBMITTED LATER AS A DEFERRED SUBMITTAL.
 DESIGNER OF RECORD TO APPROVE THEM BEFORE SUBMITTAL):
 A) PROVIDE COPIES OF THE FLAME SPREAD INDEX AND SMOKE
 DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84
 OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION
 (2017).
 NOTE: TEST SAMPLE TO MATCH BUILDING CONSTRUCTION.
  
 B) PROVIDE COPIES OF THE SOUND TRANSMISSION CLASS (STC)
 TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY
 SEC. 1207.2 OF FBC 6TH EDITION (2017).
 NOTE: TEST SAMPLE TO MATCH BUILDING CONSTRUCTION. THERE
 ARE TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT
 ACOUSTICAL CEILING.
  
 C) PROVIDE COPIES OF THE IMPACT INSULATION CLASS (IIC)
 TEST DONE IN ACCORDANCE WITH ASTM E 492 AS REQUIRED BY
 SEC. 1207.3 OF FBC 6TH EDITION (2017).
 NOTE: TEST SAMPLE TO MATCH BUILDING CONSTRUCTION. THERE
 ARE TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT
 ACOUSTICAL CEILING.
  
 6- SHEET A-460-FINISH PLAN + ELEVATIONS + DETAILS:
 PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 REINFORCEMENT AT ALL THE GRAB BARS AS REQUIRED BY
 REQUIREMENT #6 OF FAIR HOUSING ACT. NOTE: REMEMBER TYPE
 OF CONSTRUCTION. COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
 SEE SEC. 603.1 FBC FOR PERMITTED MATERIALS.
  
 7- SHEET G-201 -EXISTING LIFE SAFETY PLANS:
 A) REVISE THE EXIT ACCESS TRAVEL DISTANCE. THE DISTANCE
 IS MEASURE FORM THE MOST REMOTE POINT TO THE EXIT NOT
 TO THE ENTRY DOOR. SEE SEC. 1017.3 FBC AND REVISE AS
 REQUIRED.
  
 B)EXISTING LIFE SAFETY PLANS SHOW A FIRE EXTINGUISHER
 WHERE THE NEW CORRIDOR WALL IS BUILT FOR NEW APARTMENT.
 SPECIFY LOCATION OF RELOCATED FIRE EXTINGUISHER. SEC.
 906.1 FBC.
  
 8- SHEET G-500-UL ASSEMBLIES: PROVIDE SPECIFICATIONS
 FOR RATED CEILING ASSEMBLY. SEC. 420.3 FBC
  
 9- SHEET FP-001-GENERAL INFORMATION-FIRE PROTECTION:
 REVISE INFORMATION SPECIFIED UNDER RESIDENTIAL UNITS IN
 THE FIRE PROTECTION DESIGN CRITERIA COLUMN. THIS
 BUILDING REQUIRES A NFPA 13 SPRINKLER SYSTEM. SEC.
 903.3.2 FBC. NFPA 13R SPRINKLER SYSTEM IS NOT ALLOWED.
 NFPA 13R SYSTEM IS FOR LOW RISE RESIDENTIAL
 OCCUPANCIES. REVISE AS REQUIRED.
 SEPARATE PERMIT REQUIRED.
  
 10- PROVIDE SPECIFICATIONS FOR FIRE ALARM AND SMOKE
 ALARMS. SEC. 907.2.9 FBC.
 SEPARATE PERMIT REQUIRED.
  
 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 PENETRATIONS IF FIRE RATED HORIZONTAL ASSEMBLIES AND
 FIRE RATED WALLS.
 SEC. 714 FBC.
  
 12- THIS IS A DIGITAL SUBMITTAL. ALL DRAWINGS NEED TO
 HAVE DIGITAL SIGNATURE AS REQUIRED BY CHAPTER 481 FOR
 ARCHITECTS AND CHAPTER 471 FOR ENGINEERS.
  
 13- PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-12-11 Cont ID  
Sent By jpearson Date 2018-12-11 Time 11:01 Rev Time 0.00
Received By jpearson Date 2018-12-11 Time 11:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-10-07 Cont ID  
Sent By jpearson Date 2018-10-07 Time 13:54 Rev Time 0.00
Received By jpearson Date 2018-10-07 Time 13:54 Sent To  
Notes
2018-10-07 13:54:34CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. CORRECTED.
 2. DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE. PROVIDE
 CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481 (NOT
 CORRECTED, SEE NOTES IN SIGNATURE STOP.)
 3. CORRECTED.
 4. CORRECTED.
 5. CORRECTED.
 6. CORRECTED.
 7. CORRECTED.
  
 NEW COMMENT:
  
 8. NO VALUE FOR WORK STATED ON PERMIT APPLICATIONS.
 PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE OF
 WORK, TO INCLUDE ALL MATERIALS AND LABOR. THE VALUE
 LISTED ON EACH PERMIT APPLICATION SHOULD BE FOR THE
 WORK THAT IS INCLUDED IN THAT PORTION OF THE PROJECT.
 FBC 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-07-23 Cont ID  
Sent By jpearson Date 2018-07-23 Time 11:00 Rev Time 0.00
Received By jpearson Date 2018-07-23 Time 11:00 Sent To  
Notes
2018-07-23 11:00:48CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NOTE G2 ON SHEET E-001 AND SHEET G-100 SPECIFY THE
 WRONG CODE FOR DESIGN. THESE ARE IN CONFLICT WITH OTHER
 AREAS OF THE PLAN THAT STATE THE CURRENT CODE. CORRECT
 DISCREPANCIES. WPB FBC 107.2.1; FBC PREFACE
 2. DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE. PROVIDE
 CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481
 3. BE ADVISED THAT FIRE ALARM IS NOT INCLUDED IN THE
 SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN
 SUBMITTALS FOR THIS. WPB FBC 105.1, 107.2.1
 4. SHEET E-002 HAS A NOTE FOR PATIENT CARE AREAS, BUT
 REVIEWER DOES NOT SEE ANY PATIENT CARE AREAS IDENTIFIED
 ON PLAN. PROVIDE CLARIFICATION AND/OR CORRECTION. WPB
 FBC 107.2.1
 5. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL TO CONFIRM THE STATED AIC RATING OF THE PANELS IS
 ADEQUATE. NEC 110.9, 110.10
 6. NOTE ON PANEL SCHEDULE INDICATES THAT ALL BREAKERS
 SHALL BE AFCI TYPE. BRANCH CIRCUITS THAT FEED EQUIPMENT
 SUCH AS A RANGE OR AN AC ARE NOT TYPICALLY INSTALLED
 WITH AFCI PROTECTION. PROVIDE CLARIFICATION AS TO WHICH
 CIRCUITS ARE AFCI PROTECTED PER CODE. NEC 210.12
 7. PLAN SHOWS WHAT APPEARS TO BE A STANDARD RECESS
 LIGHT OVER SHOWER. LIGHTING IN BATHTUB OR SHOWER AREAS
 SHALL BE SUITABLE FOR DAMP LOCATIONS. PROVIDE
 CORRECTION. NEC 410.10(D)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2018-11-20 Cont ID  
Sent By pleduc Date 2018-11-20 Time   Rev Time 0.00
Received By pleduc Date 2018-11-20 Time 14:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-09-24 Cont ID  
Sent By pleduc Date 2018-09-24 Time   Rev Time 0.00
Received By pleduc Date 2018-09-24 Time 12:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-06-27 Cont ID  
Sent By pleduc Date 2018-06-27 Time   Rev Time 0.00
Received By pleduc Date 2018-06-27 Time 08:39 Sent To  
Notes
2018-06-27 09:25:10THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) THE SUBMITTED PLAN INDICATES ONE ADDRESS - 315 S
 FLAGLER DR., HOWEVER, THEY INDICATE WORK ON FLOORS 10 -
 11 & 12, WHICH APPEARS TO BE INDIVIDUAL UNITS.
  
 THERE IS NO INDICATIONS OF INTERNAL STAIRS CONNECTING
 THE FLOORS.
  
 THESE INDIVIDUAL UNITS ARE NOT INDICATED WITH THEIR
 CORRESPONDING NUMBERS.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY IN ADDITION TO # 2
 BELOW
  
  
  
 2) EACH OF THESE INDIVIDUAL UNITS WITH THE PROPOSED
 WORK SHOULD BE SUBMITTED UNDER INDIVIDUAL PERMITS WITH
 THE CORRESPONDING UNIT NUMBERS AS NOTED IN # 1 ABOVE.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 3) A FIRE SPRINKLER SHEET WAS PROVIDED; HOWEVER, THERE
 IS NO INDICATION THAT THE WORK SHALL BE DONE UNDER
 SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY
 CONTRACTORS.
  
 THE FIRE SPRINKLER SYSTEM SHALL BE MAINTAINED AND
 OPERATIONAL DURING ALL CONSTRUCTION PERIODS.
  
 IF THE SYSTEM IS DOWN FOR MORE THAN 4 HOURS, YOU ARE
 REQUIRED TO NOTIFY THE AHJ AND CONDUCT A FIRE WATCH.
  
 PLEASE REVIEW AND CORRECT FOR EACH INDIVIDUAL UNIT.
  
  
  
  
 4) THERE IS NO INDICATION OF WORK ON THE FIRE ALARM
 SYSTEM AND THAT ANY WORK ON THE FIRE ALARM SYSTEM SHALL
 BE DONE UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE
 SAFETY CONTRACTORS.
  
 THE FIRE ALARM SYSTEM SHALL BE MAINTAINED AND
 OPERATIONAL DURING ALL CONSTRUCTION PERIODS.
  
 IF THE SYSTEM IS DOWN FOR MORE THAN 4 HOURS, YOU ARE
 REQUIRED TO NOTIFY THE AHJ AND CONDUCT A FIRE WATCH.
  
 PLEASE REVIEW AND CORRECT FOR EACH INDIVIDUAL UNIT.
  
  
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-02-13 Cont ID  
Sent By lmarchan Date 2019-02-13 Time 11:36 Rev Time 0.00
Received By lmarchan Date 2019-01-14 Time 14:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-01-04 Cont ID  
Sent By gjohnson Date 2019-01-04 Time 16:40 Rev Time 0.00
Received By gjohnson Date 2018-11-19 Time 16:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-10-30 Cont ID  
Sent By gjohnson Date 2018-10-30 Time 08:54 Rev Time 0.00
Received By gjohnson Date 2018-09-18 Time 12:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-15 Cont ID  
Sent By cpuell Date 2018-08-15 Time 13:17 Rev Time 0.00
Received By cpuell Date 2018-06-25 Time 15:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2019-02-05 Cont ID  
Sent By ccole Date 2019-02-05 Time 12:00 Rev Time 0.00
Received By ccole Date 2019-02-05 Time 11:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2018-12-14 Cont ID  
Sent By ccole Date 2018-12-14 Time 10:00 Rev Time 0.00
Received By ccole Date 2018-12-14 Time 07:58 Sent To  
Notes
2018-12-14 10:07:023RD REVIEW FBC-2017 MECHANICAL
 PERMIT #18060308
 12/14/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-121: THE EXHAUST DUCT HAS BEEN REMOVED FOM
 THE KITCHEN. PLEASE SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE RANGE HOOD SHOWING COMPLIANCE
 WITH TABLE 403.3.1.1 AND SECTION 505.1 EXCEPTION 1.
  
 2) SUBMIT MANUFACTURER'S FOR THE NEW O/A DAMPERS-
 SECTION C403.2.4.3 FBC M.
  
 3) PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE NEW HEAT
 PUMPS- SECTION 307.2 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-10-18 Cont ID  
Sent By ccole Date 2018-10-18 Time 08:06 Rev Time 0.00
Received By ccole Date 2018-10-17 Time 16:53 Sent To  
Notes
2018-10-18 08:14:352ND REVIEW FBC-2017 MECHANICAL
 PERMIT #18060308
 10/18/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE 16X8 TRANSFER GRILL FOR THE LARGE BEDROOM IS
 UNDERSIZED PER SECTION 601.6 FBC M (2)- 50 SQ. INCHES
 PER 100 CFMS REQUIRED FOR BALANCED AIR. IN ADDITION, IT
 APPEARS THAT THE AIR FROM THE BEDROOM THAT IS SUPPLIED
 BY HP-A WILL BE TRANSFERRED DIRECTLY INTO THE MAIN
 RETURN GRILL OF HP-B WHICH WILL CAUSE AN IMBALNCE IN
 THE SYSTEMS. A BETTER OPTION MAY BE TO DUCT THE RETURN
 DIRECTLY TO HP-B.
  
 2) THE NEW KITCHEN EXHAUST SHALL BE RUN INDEPENDENTLY
 OF THE TOILET ROOM EXHAUST, AND MUST MEET ALL THE
 COMPLIANCES LISTED UNDER SECTION 505.3 FBC M- SEE
 BELOW.
  
 505.3 COMMON EXHAUST SYSTEMS FOR DOMESTIC KITCHENS
 LOCATED IN MULTISTORY STRUCTURES.
  
 WHERE A COMMON MULTISTORY DUCT SYSTEM IS DESIGNED AND
 INSTALLED TO CONVEY EXHAUST FROM MULTIPLE DOMESTIC
 KITCHEN EXHAUST SYSTEMS, THE CONSTRUCTION OF THE SYSTEM
 SHALL BE IN ACCORDANCE WITH ALL OF THE FOLLOWING:
  
 1.THE SHAFT IN WHICH THE DUCT IS INSTALLED SHALL BE
 CONSTRUCTED AND FIRE-RESISTANCE RATED AS REQUIRED BY
 THE FLORIDA BUILDING CODE, BUILDING.
  
 2.DAMPERS SHALL BE PROHIBITED IN THE EXHAUST DUCT,
 EXCEPT AS SPECIFIED IN SECTION 505.1. PENETRATIONS OF
 THE SHAFT AND DUCTWORK SHALL BE PROTECTED IN ACCORDANCE
 WITH SECTION 607.5.5, EXCEPTION 2.
  
 3.RIGID METAL DUCTWORK SHALL BE INSTALLED WITHIN THE
 SHAFT TO CONVEY THE EXHAUST. THE DUCTWORK SHALL BE
 CONSTRUCTED OF SHEET STEEL HAVING A MINIMUM THICKNESS
 OF 0.0187 INCH (0.4712 MM) (NO. 26 GAGE) AND IN
 ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS.
  
 4.THE DUCTWORK WITHIN THE SHAFT SHALL BE DESIGNED AND
 INSTALLED WITHOUT OFFSETS.
  
 5.THE EXHAUST FAN MOTOR DESIGN SHALL BE IN ACCORDANCE
 WITH SECTION 503.2.
  
 6. THE EXHAUST FAN MOTOR SHALL BE LOCATED OUTSIDE OF
 THE AIRSTREAM.
  
 7.THE EXHAUST FAN SHALL RUN CONTINUOUSLY, AND SHALL BE
 CONNECTED TO A STANDBY POWER SOURCE.
  
 8. EXHAUST FAN OPERATION SHALL BE MONITORED IN AN
 APPROVED LOCATION AND SHALL INITIATE AN AUDIBLE OR
 VISUAL SIGNAL WHEN THE FAN IS NOT IN OPERATION.
  
 9.WHERE THE EXHAUST RATE FOR AN INDIVIDUAL KITCHEN
 EXCEEDS 400 CFM (0.19 M3/S) MAKEUP AIR SHALL BE
 PROVIDED IN ACCORDANCE WITH SECTION 505.2.
  
 10.A CLEANOUT OPENING SHALL BE LOCATED AT THE BASE OF
 THE SHAFT TO PROVIDE ACCESS TO THE DUCT TO ALLOW FOR
 CLEANOUT AND INSPECTION. THE FINISHED OPENINGS SHALL BE
 NOT LESS THAN 12 INCHES BY 12 INCHES (305 MM BY 305
 MM).
  
 11.SCREENS SHALL NOT BE INSTALLED AT THE TERMINATION.
  
 12.THE COMMON MULTISTORY DUCT SYSTEM SHALL SERVE ONLY
 KITCHEN EXHAUST AND SHALL BE INDEPENDENT OF OTHER
 EXHAUST SYSTEMS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-07-11 Cont ID  
Sent By ccole Date 2018-07-11 Time 17:53 Rev Time 0.00
Received By ccole Date 2018-07-11 Time 17:53 Sent To  
Notes
2018-07-11 18:06:591ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18060308
 7/11/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-121: PROVIDE A MEANS OF RETURNING AIR FROM
 THE BEDROOMS- SECTION 601.6 FBC M.
  
 2) M-121: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 NEW COOKING APPLIANCE- SECTION 917.1 FBC M.
  
 3) M-121: EXHAUST VENTILATION IS REQUIRED FOR THE
 KITCHEN AT A RATE OF 25 CFMS CONTINUOUS, OR 100 CFMS
 INTERMITTENTLY PER TABLE 403.3.1.1 FBC M. INDICATE IF A
 NEW KITCHEN EXHAUST HOOD AND EXHAUST DUCT ARE TO BE
 INSTALLED AND: A) SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR THE SYSTEM. B) PROVIDE A DETAIL SHOWING THE EXHAUST
 DUCT RUN AND TERMINATION LOCATION- SECTION 505 FBC M
  
 4) CLARIFY IF A NEW OR RELOCATED DRYER IS TO BE
 INSTALLED AND: A) SUBMIT MANUFACTURER'S SPECIFICATIONS.
 B) SHOW THE LOCATION OF THE DRYER AND THE EXHAUST DUCT
 RUN AND TERMINATION LOCATION.- SECTION 504 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2019-02-13 Cont ID  
Sent By gjohnson Date 2019-02-13 Time 08:30 Rev Time 0.00
Received By gjohnson Date 2019-02-13 Time 08:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-01-04 Cont ID  
Sent By gjohnson Date 2019-01-04 Time 16:40 Rev Time 0.00
Received By gjohnson Date 2019-01-04 Time 16:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-10-30 Cont ID  
Sent By gjohnson Date 2018-10-30 Time 08:50 Rev Time 0.00
Received By gjohnson Date 2018-10-30 Time 08:50 Sent To  
Notes
2018-10-30 08:52:201ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. A121 THE CLEAR FLOOR SPACE FOR THE SHOWER SHALL
 BE FLUSH WITH THE CONTROL WALL. PER FHA DESIGN MANUAL
 REQUIREMENT #7 PG. 7.56
 2. SHT. A121 IN THE CLEAR FLOOR SPACE FOR THE SHOWER
 THE LAVATORY SHALL BE ALLOWED TO OVERLAP THE CLEAR
 FLOOR SPACE ONLY 6? PLEASE CLARIFY THIS ON THE PLAN.
 PER FHA DESIGN MANUAL REQUIREMENT #7 PG. 7.57
 3. THE VANITY AND THE WING WALL NEXT TO THE VANITY
 SHALL HAVE A DEPTH NO MORE THAN 24?. PER FHA DESIGN
 MANUAL REQUIREMENT #7 PG. 7.44
 4. PLEASE LABEL ALL THE CLEAR FLOOR SPACE FOR THE
 PLUMBING FIXTURES IN THE BATHROOM WITH THE DIMENSIONS.
 PER FHA DESIGN MANUAL REQUIREMENT #7 PG. 7.43, 7.47,
 7.52, 7.56
 5. ALL BATHROOMS SHALL HAVE GRAB BAR BACKING PLEASE
 PROVIDE DETAIL DRAWINGS SHOWING THE LOCATION AND HEIGHT
 DIMENSIONS FOR THE GRAB BAR BACKING. PER FHA DESIGN
 MANUAL REQUIREMENT #6 PG. 6.3-6.13
 6. PLEASE CLARIFY WHAT TYPE OF SHOWER ENCLOSURE IS BE
 INSTALLED, UNDER THE PLUMBING FIXTURE SCHEDULE IT
 STATES AN ACRYLIC SHOWER STALL AND UNDER THE SPECS IT
 STATES A TILED SHOWER IF IT IS A TILED SHOWER PLEASE
 PROVIDE THE MANUFACTURE SPECIFICATIONS FOR THE SHOWER
 PAN WATER PROOFING. PER WPB AMEND TO FBC 107.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-08-02 Cont ID  
Sent By gjohnson Date 2018-08-02 Time 10:36 Rev Time 0.00
Received By gjohnson Date 2018-08-02 Time 10:36 Sent To  
Notes
2018-08-02 11:02:241ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE DEFINE THE OCCUPANCY TYPE OF THE BUILDING AND
 THE FLOORS THE UNITS ARE LOCATED THIS BEING A MIXED
 OCCUPANCY SEE BUILDINGS COMMENTS. PER WPB AMEND TO FBC
 107.2.1
  
 2. PLEASE CLARIFY WHAT ACCESSIBILITY CODE YOU ARE
 COMPILING WITH. PER WPB AMEND TO FBC 107.2.1
  
 3. SHT P-401 DETAIL #2 PLEASE CLARIFY WHAT IS A TYPICAL
 SANITARY TRANSITION IS ALSO THE THE VENTING SHALL BE
 SHOWN. PER FBC PL 901.2.1
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2019-02-13 Cont ID  
Sent By lmarchan Date 2019-02-13 Time 11:36 Rev Time 0.00
Received By lmarchan Date 2019-02-13 Time 08:32 Sent To  
Notes
2019-02-13 08:33:182/13/19 DIG SIG ON PLUMB OK

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2018-12-11 Cont ID  
Sent By jpearson Date 2018-12-11 Time 11:01 Rev Time 0.00
Received By jpearson Date 2018-12-11 Time 11:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2018-10-07 Cont ID  
Sent By jpearson Date 2018-10-07 Time 13:34 Rev Time 0.00
Received By jpearson Date 2018-10-07 Time 13:34 Sent To  
Notes
2018-10-07 13:34:38DIGITAL PLANS ARE REQUIRED TO HAVE A DIGITAL
 SIGNARTURE. WPB FBC 107.1, 107.2; FS 471, 481
  
 THE FOLLOWING SHEETS DO NOT HAVE THE DIGITAL SIGNATURE
 REQUIRED: A-111, A-121, A-460, G-001, G-010, G-100,
 G-150, G-201, G-500, I-100, I-510, M-001, M-221, M-301,
 P-001, P-121, P-221, P-301, P-401, S-121.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-07-23 Cont ID  
Sent By jpearson Date 2018-07-23 Time 09:17 Rev Time 0.00
Received By jpearson Date 2018-07-23 Time 09:15 Sent To  
Notes
2018-07-23 09:17:47DIGITAL PLANS ARE REQUIRED TO HAVE A DIGITAL
 SIGNARTURE. WPB FBC 107.1, 107.2; FS 471, 481

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status P Date 2018-10-22 Cont ID  
Sent By dbattles Date 2018-10-22 Time 11:05 Rev Time 0.00
Received By dbattles Date 2018-10-22 Time 11:05 Sent To  
Notes
2018-10-22 11:05:43SEE PROVISO IN BUILDING COMMENT.

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status F Date 2018-07-26 Cont ID  
Sent By jgomez Date 2018-07-26 Time 14:59 Rev Time 0.00
Received By jgomez Date 2018-07-26 Time 14:59 Sent To  
Notes
2018-07-26 15:08:48THIS IS A THRESHOLD BUILDING. SPECIAL INSPECTOR MAY BE
 REQUIRED FOR NEW FLOOR PENETRATIONS INTO EXISTING POST
 TENSIONED SLAB. LOCATION OF PT TENDONS AND
 REINFORCEMENT IN SLAB IS REQUIRED BEFORE CORE DRILLING.
 COORDINATE WITH KEN CONRAD (CHIEF BUILDING INSPECTOR)
 PRIOR TO ANY WORK. SEE CONTACT INFORMATION BELOW.
  
  
 KEN CONRAD
 CHIEF BUILDING INSPECTOR
 DEVELOPMENT SERVICES
 BUILDING INSPECTIONS
  
 401 CLEMATIS STREET
 P.O.BOX 3366
 WEST PALM BEACH, FL 33402
 PHONE: 805-6666 EXT: 6666
 FAX: 659-8026
 E-MAIL: [email protected]
 SERVING SINCE SEP 30, 2001
 EMPLOYMENT CATEGORY: FR
 SUPERVISOR: GATHRIGHT, RICHARD EUGENE JR
  
  

Review Stop Z ZONING
Rev No 1 Status N Date 2018-07-03 Cont ID  
Sent By AA Date 2018-07-03 Time 16:15 Rev Time  
Received By aaponte Date   Time   Sent To  
Notes
2018-07-03 16:15:35INTERIOR UNIT RENOVATION ONLY.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved