Plan Review Details - Permit 18051514
Plan Review Stops For Permit 18051514
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-06-14 Cont ID  
Sent By shill Date 2018-06-14 Time 18:21 Rev Time 0.00
Received By shill Date 2018-06-14 Time 18:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-06-06 Cont ID  
Sent By shill Date 2018-06-06 Time 17:44 Rev Time 0.00
Received By shill Date 2018-06-06 Time 17:44 Sent To  
Notes
2018-06-06 17:48:13****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 905.2.2, REVISE APPLICATION TO INCLUDE ROOF
 SLOPE. THE INFORMATION PROVIDED ON THE APPLICATION -
 "SLOPE:552 FLAT:351" IS NOT CONSISTENT WITH THE
 BUILDING CODE. SLOPE TO BE SPECIFIED AS RISE AND RUN OR
 DEGREES.
  
 A DOUBLE UNDERLAYMENT IS REQUIRED FOR ROOF SLOPE LESS
 THAN 4/12. IF A DOUBLE UNDERLAYMENT IS REQUIRED, REVISE
 APPLICATION TO STATE THAT A DOUBLE LAYER WILL BE
 INSTALLED.
  
 2. IT APPEARS THAT THE LOW SLOPE ROOF IS IN THE SCOPE
 OF THIS PERMIT; PROVIDE PRODUCT APPROVAL WITH THE
 ASSEMBLY PROPOSED INDICATED. PROVIDE ENGINEERING IF
 REQUIRED.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-14 Cont ID  
Sent By shill Date 2018-06-14 Time 18:21 Rev Time 0.00
Received By shill Date 2018-06-11 Time 13:51 Sent To  
Notes
2018-06-12 13:51:45RESUB ROUTED TO SHILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-06 Cont ID  
Sent By shill Date 2018-06-06 Time 17:48 Rev Time 0.00
Received By shill Date 2018-05-31 Time 10:20 Sent To  
Notes
2018-06-01 10:21:11SHILL