Plan Review Details - Permit 18051366
Plan Review Stops For Permit 18051366 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-06-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-06-22 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-06-22 |
Time |
13:39 |
Sent To |
I |
|
Notes |
2018-06-22 13:41:20 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | FILLING THE POOL WITH WATER. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-06-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-06-08 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-06-08 |
Time |
10:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2018-06-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-03 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-03 |
Time |
06:57 |
Sent To |
|
|
Notes |
2018-06-03 07:22:53 | THERE IS NO GAS ON THIS POOL. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-07-24 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-07-24 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-07-11 |
Time |
14:53 |
Sent To |
|
|
Notes |
2018-07-12 14:53:38 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-06-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-06-22 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-05-29 |
Time |
13:26 |
Sent To |
|
|
Notes |
2018-05-30 13:27:02 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-07-24 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-07-24 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-07-24 |
Time |
18:24 |
Sent To |
|
|
Notes |
2018-07-24 18:25:58 | 07/24/18 APPROVED BY PLUMBING AND SENT TO PROCESSING, | | LAC |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-06-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-03 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-03 |
Time |
06:57 |
Sent To |
|
|
Notes |
2018-06-03 07:22:11 | 1) THE SUCTION OUTLET SAGETY CCOMPLIANCE DATA SHEET | | SHOWS THAT THE SYSTEM FLOW RATE HAS BEEN DETERMINED BY | | THE MAXIMUM FLOW FROM THE PUMP CURVE. THIS METHOD IS NO | | LONGER PERMITTED BY APSP/ANSI-7 2013 EDITION SEC. | | 4.4.9. TOTAL DYNAMIC HEAD CALCULATIONS ARE REQUIRED. | | 2) IDENTIFY ON THE PUMP CURVE GRAPH THE PUMP BEING | | INSTALLED. SUBMIT A CURVE SHOWING THE GRADIENT LINES SO | | THE MAXIMUM FLOW CAN BE DETERMINED FROM THE TDH | | CALCULATIONS. | | 3) SHT. 2 OF 3 REFERS TO SEC. 424 OF THE FLORIDA | | BULDING CODE. THIS CODE SECTION IS FOR CHILDREN'S PLAY | | STRUCTURES, NOT SWIMMING POOLS. PLEASE REVISE THE NOTE | | TO THE CORRECT CODE SECTION(S). | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-05-31 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-05-31 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-05-31 |
Time |
15:59 |
Sent To |
B |
|
Notes |
|
|
|