Plan Review Stops For Permit 18051301 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-06-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-16 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-16 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-07-30 |
Time |
07:33 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-07-30 |
Time |
06:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-06-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-06-18 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-06-18 |
Time |
15:29 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-05-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-05-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-05-31 |
Time |
12:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-08-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-08-24 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-08-24 |
Time |
10:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-08-13 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-08-07 |
Time |
14:56 |
Sent To |
|
|
Notes |
2018-08-08 14:56:23 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-08-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-08-06 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-07-06 |
Time |
14:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-06-19 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-05-25 |
Time |
09:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-07-16 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-07-16 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-06-19 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-06-19 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-06-19 |
Time |
17:12 |
Sent To |
I |
|
Notes |
2018-06-19 17:26:34 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18051301 | | 6/19/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) REFER TO TABLE 403.3.1.1 FBC M FOR THE MINIMUM | | VENTILATION RATES FOR A NEW BARBER SHOP: A) AN EXHAUST | | SYSTEM WITH A MINIMUM AIRFLOW RATE 0.5 CFMS PER SQ. FT. | | B) OUTDOOR AIR FOR OCCUPANTS BASED ON 25 PERSONS PER | | 1000 SQ. FT. AT 7.5 CFMS PER PERSON + 0.6 CFMS PER SQ. | | FT. PLEASE PROVIDE MECHANICAL PLANS AND CALCULATIONS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-08-24 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-08-24 |
Time |
10:21 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2018-08-13 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-08-13 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-08-13 |
Time |
14:27 |
Sent To |
I |
|
Notes |
2018-08-13 14:29:00 | | | 1) PROVIDE THE MANUFACTURES COMPLETE MANUAL OF CHAIR | | FIXTURE EQUIPMENT SHOWING IT COMPLIES WITH ASSE 1070. | | FBC P 423.3. 3RD REQUEST. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-08-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-08-06 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-08-06 |
Time |
13:56 |
Sent To |
I |
|
Notes |
2018-08-06 13:57:57 | | | 1) PROVIDE THE MANUFACTURES COMPLETE MANUAL OF CHAIR | | FIXTURE EQUIPMENT SHOWING IT COMPLIES WITH ASSE 1070. | | FBC P 423.3. 2ND REQUEST | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-06-18 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-06-18 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-06-18 |
Time |
17:43 |
Sent To |
M |
|
Notes |
2018-06-18 17:48:32 | 06/18/18 1ST PLUMBING REVIEW**DENIED** | | | | 1) PROVIDE THE MANUFACTURES COMPLETE MANUAL OF CHAIR | | FIXTURE EQUIPMENT SHOWING IT COMPLIES WITH ASSE 1070. | | FBC P 423.3 | | | | 2) EXISTING TANKLESS WATER HEATER IS A POINT OF USE | | ONLY IS WILL BE UNDERSIZED BY ADDING THIS NEW | | EQUIPMENT. HEATER MUST BE ABLE TO PRODUCE HOT WATER @ | | FULL DEMAND. FBC P 604.3 | | | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | |
|
|