Plan Review Details - Permit 18051261
Plan Review Stops For Permit 18051261 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-19 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-19 |
Time |
17:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-06-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-09 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-09 |
Time |
08:36 |
Sent To |
|
|
Notes |
2018-06-09 08:53:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. REVISE PLAN OR APPLICATION TO INDICATE REASON FOR A | | TEMPORARY FENCE, FBC 107. | | | | 2. IF THIS IS ASSOCIATED WITH A CONSTRUCTION PROJECT, | | REVISE PLAN TO SHOW COMPLIANCE WITH FBC B 3306.1, | | PROTECTION OF PEDESTRIANS. PROVIDE A SITE PLAN TO SHOW | | LOCATION OF PROPOSED CONSTRUCTION, HEIGHT OF PROPOSED | | CONSTRUCTION, AND DISTANCE TO PROPERTY LINES. IF A | | BARRIER OR BARRIER AND COVERED WALKWAY ARE REQUIRED, | | INDICATE SUCH ON THE PLAN. | | | | NOT ENOUGH INFORMATION WAS PROVIDED TO DETERMINE CODE | | COMPLIANCE. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-07-13 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-07-13 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-06-01 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-06-01 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-06-01 |
Time |
11:04 |
Sent To |
|
|
Notes |
2018-06-01 12:19:15 | PERMIT # 18051261 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | 1) PER CHAPTER 18 (NFPA 1): FIRE DEPARTMENT ACCESS | | SHALL HAVE AN UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 | | FEET AND AN UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS | | THAN 13 FEET 6 INCHES. | | | | 2) IF ACCESS GATES WILL BE SECURED BY A LOCK AND/OR | | CHAIN, IT IS RECOMMENDED THAT A KNOX KEY PADLOCK BY | | PROVIDED FOR EMERGENCY ACCESS. | | | | 3) FENCING SHALL NOT BE PLACED IN A MANNER THAT | | OBSTRUCTS ACCESS TO ANY FIRE HYDRANTS AND/OR FIRE | | DEPARTMENT CONNECTIONS. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 804-4751 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-07-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-19 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-12 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-06-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-06-12 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-05-29 |
Time |
07:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-07-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-07-18 |
Time |
14:12 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2018-07-18 |
Time |
14:04 |
Sent To |
|
|
Notes |
2018-07-18 14:22:26 | NO MORE THAN 19 PARKING SPACES MAY BE BLOCKED AT ANY | | ONE TIME DUE TO CONSTRUCTION ACTIVITIES. | | | | PRIOR TO THE FINAL INSPECTION (104) A LANDSCAPE PERMIT | | MUST BE SUBMITTED, REVIEWED AND APPROVED BY THE CITY | | AND THE LANDSCAPE INSTALLED AND PASS INSPECTION. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2018-07-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-07-05 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2018-07-05 |
Time |
14:17 |
Sent To |
|
|
Notes |
2018-07-05 14:58:17 | PLANS NEED TO BE UPLOADED STILL - DOES NOT COUNT AS A | | ZONING REVIEW CYCLE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-06-12 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-06-12 |
Time |
12:00 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2018-06-12 |
Time |
11:59 |
Sent To |
|
|
Notes |
2018-06-12 12:13:12 | FAILED | | | | PROVIDE WRITTEN RESPONSES. | | | | 1) THE APPLICATION STATES THAT THE POSTS WILL BE DRIVEN | | INTO THE GROUND AND THE FENCE DETAIL SHEET SHOWS 18 | | INCH BURIED POSTS; HOWEVER THE PHOTO SHOWING THE FENCE | | DETAILS IS OF A FENCE SITTING ON THE GROUND WITH FEET | | AND SANDBAGS. ALL PLANS AND DETAIL MUST BE CONSISTENT. | | | | 2) THE CITY UTILITIES EASEMENT CONSENT APPROVAL WAS NOT | | PROVIDED (2 COPIES OF THE FPU WERE INCLUDED). | | | | 3) SCREENING DETAILS SHALL BE SUBMITTED WITH THE | | TEMPORARY CONSTRUCTION FENCE PERMIT APPLICATION. WIND | | SCREENING SHALL BE SUBSTANTIAL ENOUGH TO AVOID RIPS OR | | TEARS DUE TO WIND OR SUN, AND SHALL HAVE NO LESS THAN | | 85 PERCENT OPACITY. | | | | 4) TEMPORARY CONSTRUCTION FENCES MAY NOT BE ERECTED | | UNTIL A DEMOLITION PERMIT OR BUILDING PERMIT FOR THE | | LAND DISTURBING CONSTRUCTION OR LAND DEVELOPMENT | | ACTIVITIES HAS BEEN ISSUED, AND NO MORE THAN TEN DAYS | | PRIOR TO THE COMMENCEMENT OF LAND DISTURBING | | CONSTRUCTION OR LAND DEVELOPMENT ACTIVITIES. ZONING | | STAFF HAS NO RECORD OF A DEMOLITION OR BUILDING PERMIT | | SUBMITTED FOR WORK IN THE AREA OF THE TEMPORARY | | CONSTRUCTION FENCE. | | | | CONTACT ERIC SCHNEIDER @ (561) 82-1446 | | [email protected] |
|
|
|