Plan Review Details - Permit 18051063
Plan Review Stops For Permit 18051063 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-05-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-24 |
Time |
06:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-23 |
Time |
08:48 |
Sent To |
|
|
Notes |
2018-05-23 08:48:58 | PASSED WITH PROVISO; NOTIFIED APPLICANT VIA EMAIL | | | | THE MULLION IS SCANNED IN REVERSE ORDER. I'VE | | RE-SCANNED IT AND ATTACHED IT - THE NEW DOCUMENT HAS | | THE SAME NAME BUT INCLUDES THE FL NUMBER AT THE END. | | | | THE WIND PRESSURE DIAGRAM DOESN'T INDICATE MEAN ROOF | | HEIGHT. YOU CAN WRITE THIS ON YOUR WIND PRESSURE CHART | | OR FLOOR PLAN RATHER THAN MARKING UP THE ENGINEERING. | | | | FOR $250 YOU CAN "MASTER" A WIND LOAD CHART FOR EACH | | BUILDING; THEN YOU DON'T NEED TO PROVIDE AN ORIGINAL | | FOR EACH JOB. | | | | THE DESIGN PRESSURES DON'T MATCH THE ENGINEERING, SEE | | BELOW. OPENINGS 1 AND 2 ARE OK, 3 SHOULD BE | | -65.9/+65.9, 4 SHOULD BE -64.5/+63.6. SINCE SMALLER | | OPENINGS HAVE HIGHER DESIGN PRESSURES, YOU NEED TO USE | | THE SMALLER COLUMN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-22 |
Time |
17:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-22 |
Time |
17:37 |
Sent To |
|
|
Notes |
2018-05-22 17:38:24 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. THE APPLICATION IS FOR WINDOWS AND DOORS, BUT THE | | DOOR PRODUCT APPROVAL WAS NOT SUBMITTED (ONLY MULLION | | AND WINDOW). | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-05-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-24 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-23 |
Time |
08:39 |
Sent To |
|
|
Notes |
2018-05-23 08:53:22 | FORWARDED EMAIL TO SHOLDER TO UPLOAD | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-05-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-23 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-22 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
|