|
 |
 |
 |
 |
 |
Plan Review Details - Permit 18051008
Plan Review Stops For Permit 18051008 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-06-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-30 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-30 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-07-19 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-07-19 |
Time |
09:59 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-07-02 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-07-02 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-07-02 |
Time |
11:19 |
Sent To |
I |
|
Notes |
2018-07-02 12:55:51 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE RISER DIAGRAM OF EXISTING SERVICES IN TENANT | | SPACE. NEC 215.5; WPB FBC 107.2.1 | | 2. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | 8.4.2. PER THIS REQUIREMENT, THE FOLLOWING SHALL BE | | AUTOMATICALLY CONTROLLED: 1) AT LEAST 50% OF ALL | | 125-VOLT, 15 AND 20 AMP RECEPTACLES, IN ALL PRIVATE | | OFFICES, CONFERENCE ROOMS, ROOMS USED PRIMARILY FOR | | PRINTING AND/OR COPYING FUNCTIONS, BREAK ROOMS, | | CLASSROOMS, AND INDIVIDUAL WORKSTATIONS. 2) AT LEASE | | 25% OF BRANCH CIRCUIT FEEDERS INSTALLED FOR MODULAR | | FURNITURE NOT SHOWN ON THE CONSTRUCTION DOCUMENTS. FBC | | EC C405.6.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-05-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-05-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-05-25 |
Time |
12:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-07-19 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-07-17 |
Time |
15:31 |
Sent To |
|
|
Notes |
2018-07-18 15:32:07 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-07-02 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-05-22 |
Time |
13:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-07-19 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-07-19 |
Time |
14:14 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-06-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-06-21 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-06-21 |
Time |
16:02 |
Sent To |
|
|
Notes |
2018-06-21 16:48:23 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18051008 | | 6/21/18 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | RTU- SECTION C403.2.1 FBC-17 FBC EC. | | | | 2) PROVIDE COMPLETE SITE SPECIFIC ENGINEERING FOR | | INSTALLATION OF THE NEW RTU PER SECTION 301.15. PLEASE | | NOTE THE DETAILS ON SHEET M6.1 ARE MARKED "FOR | | REFERENCE ONLY", AND "CODE COMPLIANCE SHALL BE | | DETERMINED AND VERIFIED BY A LICENSED STRUCTURAL | | ENGINEER". | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | HTTPS://WWW.SURVEYMONKEY.COM/R/WESTPALMBEACHCONSTRUCTIO | | NSERVICES | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-06-29 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-06-29 |
Time |
15:57 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |