Plan Review Details - Permit 18050851
Plan Review Stops For Permit 18050851 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-16 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-16 |
Time |
15:43 |
Sent To |
|
|
Notes |
2018-06-16 16:00:05 | ****CORRECTIONS**** | | REVISED 6/20/18 | | REVISED 6/28/18 | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED | | SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | 2. PROVIDE INFORMATION ABOUT THE PREVIOUS PERMITTED | | OCCUPANCY; IS THIS A CHANGE OF OCCUPANCY? IF YES, | | REVISE PLAN TO SHOW COMPLIANCE WITH FBC EB CHAPTER 10. | | | | 3. THIS PROPERTY HAS A NUMBER OF EXPIRED PERMITS; | | PLEASE RESOLVE AT THIS TIME. AS DISCUSSED, AT LEAST | | THREE OF THE PERMITS WERE FOR THE SUBJECT UNIT. THERE | | IS AN EXPIRED ELECTRICAL PERMIT WHICH FAILED | | INSPECTION. | | | | 4. PLAN SHOW OCCUPANCY AS "WAREHOUSE" WITH 500 SF PER | | PERSON, BUT THE PLAN ALSO STATES THAT THIS IS A | | "SHOWROOM". A SHOWROOM IS MERCANTILE FBC B 309.1, 60 SF | | PER PERSON, FBC B 1004. | | | | 5. PROVIDE A DETAIL FOR THE BREAK ROOM SINK, FBC A | | 212.3, 606. | | | | 6. PLAN STATES THAT ADA BATHROOM IS "EXISTING", BUT THE | | DETAILS ARE STANDARD DETAILS. PROVIDE DETAILS OF THE | | EXISTING TO SHOW COMPLIANCE, FBC 107. | | | | 7. PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF | | RECORD, FBC 107. | | | | 8. DOES THIS SPACE HAVE AN ACCESSIBLE ROUTE, FROM | | ACCESSIBLE PARKING TO THE ENTRANCE? FBC A 202.4. REVISE | | PLAN TO SHOW COMPLIANCE. | | | | 9. REVISED 6/28/18 PURSUANT TO MEETING WITH DOUG | | HARVEY, ABO, RICHARD COHEN ATTY, & OWNER | | | | THIS BUILDING HAS A NUMBER OF EXPIRED PERMITS. AS | | DISCUSSED, INCORPORATE THE PERMITS WHICH AFFECT THIS | | UNIT INTO THIS PERMIT: | | | | 05011183, CUT WALL AND INSTALL GARAGE DOOR 9'X8' | | 06082252, TAKE DOWN WALL IN BAY 2-3 AND BUILD FIRE | | RATED WALL | | 06082253, ELECTRICAL FOR 06082252 | | | | THIS PERMIT WILL BE ISSUED WITH PROVISO; RESOLUTION OF | | EXPIRED ELECTRICAL PERMIT 08070213 REQUIRED PRIOR TO | | FINAL INSPECTION. | | | | 10. (NEW 6/28) THE PLAN INDICATES "EXISTING FIRE | | WALLS". PLEASE SEE EXPIRED PERMITS 06082252, 10070718. | | AS FINAL INSPECTIONS WERE NOT OBTAINED, THE WALLS ARE | | NOT CONSIDERED "EXISTING". THIS WORK SHOULD BE | | INCORPORATED INTO THIS PERMIT. | | | | 11. (NEW 6/28) PROVIDE INFORMATION TO SHOW COMPLIANCE | | WITH FBC B TABLE 506.2. IS THE BUILDING SPRINKLERED? | | WHAT IS THE BUILDING TYPE? | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-06-15 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-06-15 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-06-15 |
Time |
13:20 |
Sent To |
|
|
Notes |
2018-06-15 15:16:13 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. MANY AREAS OF PLAN ARE DIFFICULT TO READ. PROVIDE | | PLAN THAT IS LEGIBLE PER WPB FBC 107.2.1.3. | | 2. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC | | 109.3 | | 3. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | 4. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | 5. PROVIDE GFCI PROTECTION FOR DRINKING FOUNTAIN. THE | | GFCI DEVICE MUST BE READILY ACCESSIBLE. NEC 422.5, | | 422.52 | | 6. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | 8.4.2. PER THIS REQUIREMENT, THE FOLLOWING SHALL BE | | AUTOMATICALLY CONTROLLED: 1) AT LEAST 50% OF ALL | | 125-VOLT, 15 AND 20 AMP RECEPTACLES, IN ALL PRIVATE | | OFFICES, CONFERENCE ROOMS, ROOMS USED PRIMARILY FOR | | PRINTING AND/OR COPYING FUNCTIONS, BREAK ROOMS, | | CLASSROOMS, AND INDIVIDUAL WORKSTATIONS. 2) AT LEASE | | 25% OF BRANCH CIRCUIT FEEDERS INSTALLED FOR MODULAR | | FURNITURE NOT SHOWN ON THE CONSTRUCTION DOCUMENTS. FBC | | EC C405.6.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2018-07-18 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-07-18 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-07-18 |
Time |
11:10 |
Sent To |
|
|
Notes |
2018-07-18 11:45:28 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) THE PREVIOUS COMMENTS OF FIRE PREVENTION WERE NOT | | SPECIFICALLY ADDRESSED AND WILL BE RE-ENTERED BELOW | | | | ******************************************************* | | ******************************************************* | | **************** | | | | | | 1) THE OCCUPANCY IS INDICATED AS WAREHOUSE; HOWEVER, | | MINI SHOWROOMS ARE INDICATED WITH AN OPEN FLOOR SPACE | | INDICATED AS SHOWROOM. THIS CHANGE OF OCCUPANCY APPEARS | | TO BE MERCANTILE IN THE LIFE SAFETY CODE. | | | | PER NFPA 101, CHAPTER 6, CLASSIFICATION OF OCCUPANCY. | | | | 6.1.10.1* DEFINITION - MERCANTILE OCCUPANCY. AN | | OCCUPANCY USED | | FOR THE DISPLAY AND SALE OF MERCHANDISE. | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC FIRE | | CODE REFERENCES. | | | | | | | | 2ND REVIEW COMMENT: | | | | 1A) SHEET T 1 APPEARS TO HAVE BEEN CHANGED TO GROUP. | | THERE IS NO OCCUPANCY CLASSIFICATION IN THE FFPC | | INDICATED AS GROUP. | | | | IT CAN BE MIXED; SEPARATED OR NON SEPARATED OR MULTIPLE | | OCCUPANCY. THE LIFE SAFETY REQUIREMENTS WOULD NEED TO | | BE COMPARED AND APPLY THE MOST STRICT. | | | | | | | | | | | | 2) THERE IS A HAND WRITTEN INDICATION THAT THE | | OCCUPANCY IS "BETWEEN FIRE WALLS". THERE ARE NO | | INDICATIONS ON THE PLAN SET DRAWINGS OR LISTING | | CALL-OUTS THAT THE EXISTING WALLS ARE FIRE RATED. | | | | WHAT IS THE SEPARATION CLASSIFICATION OF THE | | SURROUNDING OCCUPANCIES? A 2 HOUR RATING IS REQUIRED. | | | | PER NFPA 101, CHAPTER 6 | | | | 6.1.14.2.2 MIXED OCCUPANCY. A MULTIPLE OCCUPANCY WHERE | | THE | | OCCUPANCIES ARE INTERMINGLED. | | 6.1.14.2.3 SEPARATED OCCUPANCY. A MULTIPLE OCCUPANCY | | WHERE THE | | OCCUPANCIES ARE SEPARATED BY FIRE RESISTANCE?RATED | | ASSEMBLIES. | | 6.1.14.3 MIXED OCCUPANCIES. | | 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE | | CLASSIFIED AS TO ITS USE IN | | ACCORDANCE WITH SECTION 6.1. | | 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST | | RESTRICTIVE | | REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS | | SEPARATE SAFEGUARDS | | ARE APPROVED. | | 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.) | | 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED, | | EACH PART OF THE | | BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED | | IN THIS CHAPTER, | | SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY | | FIRE-RESISTIVE | | ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3, | | TABLE 6.1.14.4.1(A), | | AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED | | BY APPROVED | | EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY | | 6.1.14.4.6. | | 6.1.14.4.2 OCCUPANCY SEPARATIONS SHALL BE CLASSIFIED AS | | 3-HOUR FIRE | | RESISTANCE?RATED, 2-HOUR FIRE RESISTANCE?RATED, OR | | 1-HOUR FIRE | | RESISTANCE?RATED AND SHALL MEET THE REQUIREMENTS OF | | CHAPTER 8. | | 6.1.14.4.3 THE MINIMUM FIRE RESISTANCE RATING SPECIFIED | | IN TABLE | | 6.1.14.4.1(A) AND TABLE 6.1.14.4.1(B) SHALL BE | | PERMITTED TO BE | | REDUCED BY 1 HOUR, BUT IN NO CASE SHALL IT BE REDUCED | | TO LESS THAN 1 | | HOUR, WHERE THE BUILDING IS PROTECTED THROUGHOUT BY AN | | APPROVED | | AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | 9.7.1.1(1) AND | | SUPERVISED IN ACCORDANCE WITH 9.7.2, UNLESS PROHIBITED | | BY THE | | DOUBLE-DAGGER FOOTNOTE ENTRIES IN THE TABLES. | | 6.1.14.4.4 OCCUPANCY SEPARATIONS SHALL BE VERTICAL, | | HORIZONTAL, OR | | BOTH OR, WHEN NECESSARY, OF SUCH OTHER FORM AS REQUIRED | | TO PROVIDE | | COMPLETE SEPARATION BETWEEN OCCUPANCY DIVISIONS IN THE | | BUILDING. | | 6.1.14.4.5* EACH SEPARATED PORTION OF THE BUILDING | | SHALL COMPLY | | WITH THE REQUIREMENTS FOR THE OCCUPANCY THEREIN. | | | | PLEASE PROVIDE SPECIFIC DETAILS OF THE SEPARATIONS AND | | FIRE RATING OR JUSTIFY WITH SPECIFIC FIRE CODE | | REFERENCES. | | | | | | | | | | 2A) SHEET 2 A - THERE IS A DOOR INDICATED WITHIN THE | | INDICATED FIRE WALL; HOWEVER, THE DOOR SCHEDULE DOES | | NOT INDICATE ANY FIRE RATING FOR THESE DOORS | | | | PLEASE CORRECT OR JUSTIFY. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-05-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-05-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-05-25 |
Time |
12:11 |
Sent To |
|
|
Notes |
2018-05-25 14:25:23 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) THE OCCUPANCY IS INDICATED AS WAREHOUSE; HOWEVER, | | MINI SHOWROOMS ARE INDICATED WITH AN OPEN FLOOR SPACE | | INDICATED AS SHOWROOM. THIS CHANGE OF OCCUPANCY APPEARS | | TO BE MERCANTILE IN THE LIFE SAFETY CODE. | | | | PER NFPA 101, CHAPTER 6, CLASSIFICATION OF OCCUPANCY. | | | | 6.1.10.1* DEFINITION ? MERCANTILE OCCUPANCY. AN | | OCCUPANCY USED | | FOR THE DISPLAY AND SALE OF MERCHANDISE. | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC FIRE | | CODE REFERENCES. | | | | | | | | 2) THERE IS A HAND WRITTEN INDICATION THAT THE | | OCCUPANCY IS "BETWEEN FIRE WALLS". THERE ARE NO | | INDICATIONS ON THE PLAN SET DRAWINGS OR LISTING | | CALL-OUTS THAT THE EXISTING WALLS ARE FIRE RATED. | | | | WHAT IS THE SEPARATION CLASSIFICATION OF THE | | SURROUNDING OCCUPANCIES? A 2 HOUR RATING IS REQUIRED. | | | | PER NFPA 101, CHAPTER 6 | | | | 6.1.14.2.2 MIXED OCCUPANCY. A MULTIPLE OCCUPANCY WHERE | | THE | | OCCUPANCIES ARE INTERMINGLED. | | 6.1.14.2.3 SEPARATED OCCUPANCY. A MULTIPLE OCCUPANCY | | WHERE THE | | OCCUPANCIES ARE SEPARATED BY FIRE RESISTANCE?RATED | | ASSEMBLIES. | | 6.1.14.3 MIXED OCCUPANCIES. | | 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE | | CLASSIFIED AS TO ITS USE IN | | ACCORDANCE WITH SECTION 6.1. | | 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST | | RESTRICTIVE | | REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS | | SEPARATE SAFEGUARDS | | ARE APPROVED. | | 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.) | | 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED, | | EACH PART OF THE | | BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED | | IN THIS CHAPTER, | | SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY | | FIRE-RESISTIVE | | ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3, | | TABLE 6.1.14.4.1(A), | | AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED | | BY APPROVED | | EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY | | 6.1.14.4.6. | | 6.1.14.4.2 OCCUPANCY SEPARATIONS SHALL BE CLASSIFIED AS | | 3-HOUR FIRE | | RESISTANCE?RATED, 2-HOUR FIRE RESISTANCE?RATED, OR | | 1-HOUR FIRE | | RESISTANCE?RATED AND SHALL MEET THE REQUIREMENTS OF | | CHAPTER 8. | | 6.1.14.4.3 THE MINIMUM FIRE RESISTANCE RATING SPECIFIED | | IN TABLE | | 6.1.14.4.1(A) AND TABLE 6.1.14.4.1(B) SHALL BE | | PERMITTED TO BE | | REDUCED BY 1 HOUR, BUT IN NO CASE SHALL IT BE REDUCED | | TO LESS THAN 1 | | HOUR, WHERE THE BUILDING IS PROTECTED THROUGHOUT BY AN | | APPROVED | | AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | 9.7.1.1(1) AND | | SUPERVISED IN ACCORDANCE WITH 9.7.2, UNLESS PROHIBITED | | BY THE | | DOUBLE-DAGGER FOOTNOTE ENTRIES IN THE TABLES. | | 6.1.14.4.4 OCCUPANCY SEPARATIONS SHALL BE VERTICAL, | | HORIZONTAL, OR | | BOTH OR, WHEN NECESSARY, OF SUCH OTHER FORM AS REQUIRED | | TO PROVIDE | | COMPLETE SEPARATION BETWEEN OCCUPANCY DIVISIONS IN THE | | BUILDING. | | 6.1.14.4.5* EACH SEPARATED PORTION OF THE BUILDING | | SHALL COMPLY | | WITH THE REQUIREMENTS FOR THE OCCUPANCY THEREIN. | | | | PLEASE PROVIDE SPECIFIC DETAILS OF THE SEPARATIONS AND | | FIRE RATING OR JUSTIFY WITH SPECIFIC FIRE CODE | | REFERENCES. | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-07-25 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-07-25 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-07-16 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-06-21 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-06-21 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-06-21 |
Time |
16:00 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-16 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-16 |
Time |
15:48 |
Sent To |
|
|
Notes |
2018-06-16 15:48:20 | SEE BUILDING REVIEW | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-06-18 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-06-18 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-06-18 |
Time |
16:18 |
Sent To |
|
|
Notes |
2018-06-18 17:17:40 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18050851 | | 6/18/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX= FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVBIDE MECHANICAL PLANS SHOWING ALL | | REQUIRED ALTERATIONS TO THE EXISTING SYSTEMS TO | | ACCOMODATE THE NEW FLOOR PLAN LAYOUT AND THE CHANGE OF | | OCCUPANCY. PLEASE INCLUDE VENTILATUION CALCULATIONS FOR | | ALL ROOMS AND SPACES IN COMPLIANCE WITH TABLE 403.3.1 | | FBC M. | | | | 2) AS STATED IN COMMENT #1 ABOVE, THE PROPOSED PROJECT | | APPEARS TO BE A CHANGE OF OCCUPANCY AS DEFINED IN | | SECTION 202 FBC EX. PLEASE SEE CHAPTER 10 FOR ALL | | REQUIRED COMPLIANCES, AND INDICATE THE CLASSIFICATION | | OF WORK ON COVER SHEET T-1 PER SECTION 506 FBC EX. | | | | 3) REFER TO SECTION C505.1 FBC EC SND SUBMIT AN ENERGY | | COMPLIANCE REPORT FOR THWE PROPOSED CHANGE OF | | OCCUPANCY. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
N |
Date |
2018-06-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-16 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-16 |
Time |
15:47 |
Sent To |
|
|
Notes |
2018-06-16 15:48:02 | NOT SUBSTANTIAL IMPROVEMENT | | 5 YEAR CUMULATIVE IMPROVEMENTS = $47,394 | | PAPA 2017 VALUE FOR STRUCTURE $770,273 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-06-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-06-20 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-06-19 |
Time |
15:18 |
Sent To |
|
|
Notes |
2018-06-20 11:49:11 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. THIS APPEARS TO BE A CHANGE OF OCCUPANCY AND SHALL | | STATE THAT ON THE PLAN PER FBC EX 506 AND SHALL COMPLY | | WITH FBCEX CH 10 | | | | 2. PLEASE SHOW THE REQUIRED FLOOR SPACE IN THE ADA | | BATHROOM AND LABEL CLEAR FLOOR SPACE WITH DIMENSIONS | | PER FBC ACC 304.3.1, 604.3.1 , 606.2 | | | | 3. PLEASE LABEL THE DRINKING FOUNTAIN AND SERVICE SINK | | ON THE FLOOR PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | 4. THE DRINKING FOUNTAIN SHALL HAVE A SPOUT FOR A | | STANDING PERSON AND A LOWER ONE FOR SOMONE IN A WHEEL | | CHAIR A HILO DRINKING FOUNTAIN COMPLIES PER FBC ACC | | 211.2 | | | | 5. SHT. A-2 THE THE DETAIL FOR THE CLEAR FLOOR SPACE | | AROUND THE TOILET IS NON COMPLIANT PLEASE SHOW | | COMPLIANT DIMENSIONS PER FBC ACC 604.3.1 | | | | 6. THE GRAB BARS SHALL BE MEASURE FROM THE TOP OF THE | | GRIPPING SURFACE FROM FINISHED FLOOR PER FBC ACC 609.4 | | | | 7. PROVIDE A WATER ISOMETRIC. WPB AMEND TO FBC | | 107.3.5.1.3(13) | | | | 8, THE BREAK ROOM SINK SHALL BE ACCESSIBLE AND COMPLY | | WITH FBC ACC 212.3 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2018-06-21 |
|
|
Cont ID |
|
Sent By |
MC |
Date |
2018-06-21 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-06-21 |
Time |
15:58 |
Sent To |
PC |
|
Notes |
2018-06-21 16:00:20 | ZONING REVIEW N/A, PERMIT VALUATION DOES NOT EXCEED 50% | | VALUE OF PROPERTY. | | | | MAGGIE CRUZ | | ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: 561-822-1442 | | E-MAIL: [email protected] | | |
|
|
|