Plan Review Details - Permit 18050832
Plan Review Stops For Permit 18050832
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-06-08 Cont ID  
Sent By pleduc Date 2018-06-12 Time 09:34 Rev Time 0.00
Received By cthroop Date 2018-06-08 Time 08:04 Sent To  
Notes
2018-06-08 08:15:45PROVISO ON PLANS - CONTRACTOR SHALL COMPLY WITH FBC
 CHPT. 33 SAFEGUARDS DURING CONSTRUCTION. CT

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-06-12 Cont ID  
Sent By pleduc Date 2018-05-31 Time   Rev Time 0.00
Received By pleduc Date 2018-05-31 Time 12:49 Sent To B
Notes
2018-05-31 15:04:52THIS PLAN WAS REVIEWED AND PASSED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING PROVISO COMMENTS:
  
  
 1) THERE ARE NO INDICATIONS ON THE PLANS OF HOW THE
 EXIT PATH FROM THE EXIT DOORS WILL BE PROTECTED DURING
 DEMOLITION.
  
 PER NFPA 101
  
 CJHAPTER 4 GENERAL
  
 4.6.10 CONSTRUCTION, REPAIR, AND IMPROVEMENT
 OPERATIONS.
  
 4.6.10.1* BUILDINGS, OR PORTIONS OF BUILDINGS, SHALL BE
 PERMITTED
 TO BE OCCUPIED DURING CONSTRUCTION, REPAIR,
 ALTERATIONS, OR
 ADDITIONS ONLY WHERE REQUIRED MEANS OF EGRESS AND
 REQUIRED
 FIRE PROTECTION FEATURES ARE IN PLACE AND CONTINUOUSLY
 MAINTAINED
 FOR THE PORTION OCCUPIED OR WHERE ALTERNATIVE LIFE
 SAFETY
 MEASURES ACCEPTABLE TO THE AUTHORITY HAVING
 JURISDICTION ARE IN
 PLACE.
 4.6.10.2* IN BUILDINGS UNDER CONSTRUCTION, ADEQUATE
 ESCAPE FACILITIES
 SHALL BE MAINTAINED AT ALL TIMES FOR THE USE OF
 CONSTRUCTION
 WORKERS. ESCAPE FACILITIES SHALL CONSIST OF DOORS,
 WALKWAYS, STAIRS,
 RAMPS, FIRE ESCAPES, LADDERS, OR OTHER APPROVED MEANS
 OR DEVICES
 ARRANGED IN ACCORDANCE WITH THE GENERAL PRINCIPLES OF
 THE CODE
 INSOFAR AS THEY CAN REASONABLY BE APPLIED TO BUILDINGS
 UNDER CONSTRUCTION.
  
 PLEASE ENSURE THE AREA IS PROTECTED.
  
  
 2) SHEET B1.02 - THERE ARE INDICATIONS OR REVISIONS TO
 THE FIRE DOORS.
  
 THIS IS A DEMO PERMIT. IF THERE ARE REVISIONS TO AN
 EXISTING PERMIT ANY REVISIONS SHALL BE SUBMITTED UNDER
 THAT PREVIOUSLY APPROVED MASTER PERMIT NUMBER WITH ALL
 REVISIONS CLOUDED FOR CLARITY.
  
 PLEASE REVIEW AND SUBMIT ANY REVISIONS UNDER THE
 MASTER.
  
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-08 Cont ID  
Sent By cthroop Date 2018-06-08 Time 08:14 Rev Time 0.00
Received By cthroop Date 2018-05-17 Time 15:49 Sent To I
Notes
2018-05-30 11:54:16TO LMARCHANT
2018-05-18 15:50:00ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2018-05-30 Cont ID  
Sent By mc to aa Date 2018-05-30 Time 11:53 Rev Time  
Received By aaponte Date 2018-05-18 Time   Sent To FIRE
Notes
***NONE***