Plan Review Details - Permit 18050823
Plan Review Stops For Permit 18050823
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-06-15 Cont ID  
Sent By cthroop Date 2018-06-15 Time 16:25 Rev Time 0.00
Received By cthroop Date 2018-06-15 Time 15:59 Sent To FIRE
Notes
2018-06-15 16:27:49BLDG. REVIEW APPROVED. SENT TO FIRE. PLAN PAGE WITH
 FIRE APPROVAL IS VOID. PRINT PERMIT HOLD APPLIED UNTIL
 ENGINEERING RIGHT OF WAY PERMIT OBTAINED. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-05-29 Cont ID  
Sent By cthroop Date 2018-05-29 Time 08:43 Rev Time 0.00
Received By cthroop Date 2018-05-29 Time 07:20 Sent To ENG
Notes
2018-05-29 09:15:25BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. AN EIGHT FOOT BARRIER WITH COVERED WALKWAY IS
 REQUIRED ALONG THE LENGTH OF THE BUILDING FACING 18TH
 STREET PER FBC TABLE 3306.1.
 PROTECTION OF PEDESTRIANS TABLE 3306.1
 HEIGHT OF CONSTRUCTION
 DISTANCE FROM CONSTRUCTION TO LOT LINE TYPE OF
 PROTECTION REQUIRED
 BLDG. HEIGHT - 8 FEET OR LESS
 DISTANCE TO PROPERTY LINE - LESS THAN 5 FEET REQUIRED
 PROTECTION - CONSTRUCTION RAILINGS
 - 5 FEET OR MORE - NONE
 BLDG HEIGHT - MORE THAN 8 FEET
 DISTANCE TO PROPERTY LINE - LESS THAN 5 FEET REQUIRED
 PROTECTION - BARRIER AND COVERED WALKWAY
 5 FEET OR MORE, BUT NOT MORE THAN ONE-FOURTH THE HEIGHT
 OF CONSTRUCTION - BARRIER AND COVERED WALKWAY
 5 FEET OR MORE, BUT BETWEEN ONE-FOURTH AND ONE-HALF THE
 HEIGHT OF CONSTRUCTION - BARRIER
 5 FEET OR MORE, BUT EXCEEDING ONE-HALF THE HEIGHT OF
 CONSTRUCTION - NONE
  
 2. AN ENGINEERING PERMIT AND REVIEW WILL BE REQUIRED
 FOR WORK IN A PUBLIC WAY.
 IF SCAFFOLDING OR COVERED WALKWAY EXTENDS BEYOND THE
 PRIVATE PROPERTY AND ONTO CITY RIGHT OF WAY,
 ENGINEERING WILL REQUIRE RIGHT OF WAY PERMITS. PLEASE
 CONTACT MANNY GONZALEZ AT THE ENGINEERING DEPARTMENT ?
 (561) 494-1085.
  
 3. THERE IS A DESCREPENCY BETWEEN THE SITE PLAN
 SUBMITTED FOR REVIEW AND THE SURVEY PROVIDED BY PM
 SURVEYING. THE SITE PLAN SHOWS A 15 FOOT ALLEY WITH A 5
 FOOT EASEMENT. THE SURVEY SHOWS A 10 FOOT ALLEY WITH
 THE CONSTRUCTION FENCE LOCATED ON THE PROPERTY LINE.
 CLRIFICATION IS REQUIRED BETWEEN THESE TWO DOCUMENTS.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 4. IF THE CONSTRUCTION FENCE WILL BE LOCATED ON THE
 WEST PROPERTY LINE AND ENCROACHES AN EASEMENT, PROVIDE
 THE REQUIRED UTILITY RELEASES.
 3308.2 UTILITY FIXTURES.
 BUILDING MATERIALS, FENCES, SHEDS OR ANY OBSTRUCTION OF
 ANY KIND SHALL NOT BE PLACED SO AS TO OBSTRUCT FREE
 APPROACH TO ANY FIRE HYDRANT, FIRE DEPARTMENT
 CONNECTION, UTILITY POLE, MANHOLE, FIRE ALARM BOX OR
 CATCH BASIN, OR SO AS TO INTERFERE WITH THE PASSAGE OF
 WATER IN THE GUTTER. PROTECTION AGAINST DAMAGE SHALL BE
 PROVIDED TO SUCH UTILITY FIXTURES DURING THE PROGRESS
 OF THE WORK, BUT SIGHT OF THEM SHALL NOT BE OBSTRUCTED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2018-06-20 Cont ID  
Sent By Mgonzale Date 2018-06-20 Time   Rev Time 1.00
Received By mgonzale Date 2018-06-20 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2018-05-30 Cont ID  
Sent By hhall Date 2018-05-30 Time 14:05 Rev Time 0.00
Received By hhall Date 2018-05-30 Time 14:05 Sent To I
Notes
2018-05-30 14:06:24PASSED - NO UTILITY CONFLICTS

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-06-19 Cont ID  
Sent By pleduc Date 2018-06-19 Time   Rev Time 0.00
Received By pleduc Date 2018-06-18 Time 14:43 Sent To ENG
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-05-25 Cont ID  
Sent By pleduc Date 2018-05-25 Time   Rev Time 0.00
Received By pleduc Date 2018-05-24 Time 17:25 Sent To B
Notes
2018-05-25 08:43:38THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) THERE IS NO GATE INDICATED ON THE PLAN.
  
 A GATE IS REQUIRED FOR FD EMERGENCY ACCESS AND 20' IN
 THE MINIMUM CLEARANCE OF A FIRE LANE.
  
 PER NFPA 241 SAFEGUARDING CONSTRUCTION AND ALTERATION
 OPERATIONS
  
 7.5.5 ACCESS ROADWAYS.
  
 7.5.5.1 EVERY BUILDING SHALL BE ACCESSIBLE BY FIRE
 DEPARTMENT
 APPARATUS BY MEANS OF ROADWAYS HAVING AN ALL-WEATHER
 DRIVING
 SURFACE OF NOT LESS THAN 6.1 M (20 FT) OF UNOBSTRUCTED
 WIDTH, HAVING
 THE ABILITY TO WITHSTAND THE LIVE LOADS OF FIRE
 APPARATUS, AND
 HAVING A MINIMUM OF 4.1 M (13 FT 6 IN.) OF VERTICAL
 CLEARANCE.
  
 7.5.5.2 ACCESS FOR USE OF FIRE DEPARTMENT APPARATUS
 SHALL BE
 PROVIDED TO THE IMMEDIATE JOB SITE AT THE START OF THE
 PROJECT
 AND MAINTAINED UNTIL COMPLETION.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By mgonzale Date 2018-06-20 Time 16:05 Rev Time 0.00
Received By lmarchan Date 2018-06-12 Time 13:39 Sent To  
Notes
2018-06-13 13:39:49RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-05-30 Cont ID  
Sent By cpuell Date 2018-05-30 Time 14:15 Rev Time 0.00
Received By cpuell Date 2018-05-17 Time 11:05 Sent To  
Notes
2018-05-18 11:05:26ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2018-06-14 Cont ID  
Sent By mcruz Date 2018-06-14 Time 15:26 Rev Time 0.00
Received By mcruz Date 2018-06-14 Time 15:11 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By mcruz Date 2018-05-23 Time   Rev Time  
Received By   Date 2018-05-23 Time   Sent To FIRE
Notes
2018-05-23 11:08:02ZONING REVIEW **FAILED**
  
 1) PURSUANT TO SEC. 94-316-D(2), TEMPORARY CONSTRUCTION
 FENCES SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS:
 TEMPORARY CONSTRUCTION FENCES INSTALLED PURSUANT TO
 THIS SECTION SHALL BE SUBJECT TO THE VISIBILITY AT
 INTERSECTIONS REQUIREMENTS OF SUBSECTION 94-305(E) OF
 THIS CODE.
  
 SEE ENCLOSED DETAIL FOR SPECIFICATIONS.
  
 NOTE - GATES SHALL BE CHAINED AND LOCKED WITH A LOCK
 SUBSTANTIAL ENOUGH TO ENSURE CLOSURE AND SECURITY WHEN
 WORKERS ARE NOT ON THE JOB SITE.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES WEBSITE AT HTTP://WPB.ORG/DEPARTME
 NTS/DEVELOPMENT-SERVICES/OVERVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1442
 E-MAIL: [email protected]
  