Plan Review Details - Permit 18050633
Plan Review Stops For Permit 18050633
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-07-07 Cont ID  
Sent By shill Date 2018-07-07 Time 18:52 Rev Time 0.00
Received By shill Date 2018-07-07 Time 18:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-06-16 Cont ID  
Sent By shill Date 2018-06-16 Time 14:47 Rev Time 0.00
Received By shill Date 2018-06-16 Time 14:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-06-04 Cont ID  
Sent By jleahy Date 2018-06-04 Time 16:57 Rev Time 0.00
Received By jleahy Date 2018-06-04 Time 16:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-07-16 Cont ID  
Sent By lmarchan Date 2018-07-16 Time 16:03 Rev Time 0.00
Received By lmarchan Date 2018-06-20 Time 13:40 Sent To  
Notes
2018-06-21 13:40:26R12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-16 Cont ID  
Sent By shill Date 2018-06-16 Time 14:47 Rev Time 0.00
Received By shill Date 2018-05-14 Time 13:00 Sent To  
Notes
2018-05-15 13:00:56R12

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-07-12 Cont ID  
Sent By cmontell Date 2018-07-12 Time 13:05 Rev Time 0.00
Received By cmontell Date 2018-07-12 Time 12:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-05-23 Cont ID  
Sent By cmontell Date 2018-05-23 Time 14:36 Rev Time 0.00
Received By cmontell Date 2018-05-23 Time 13:52 Sent To  
Notes
2018-05-23 14:14:21EXHAUST FAN / EXHAUST HOOD - EF2 DOES NOT SPECIFY RATE
 OF EXHAUST (CFM) PLEASE SEE CODE SECTION ATTACHED.
  
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
  
  
 M1503.4 MAKEUP AIR REQUIRED.
 EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF
 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE
 MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A
 RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH
 MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH NOT LESS THAN
 ONE DAMPER. EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN
 ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS
 WHEN THE EXHAUST SYSTEM OPERATES. DAMPERS SHALL BE
 ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND
 REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION OR
 ANY OTHER DUCTS NOT CONNECTED TO THE DAMPER BEING
 INSPECTED, SERVICED, REPAIRED OR REPLACED.
  
 EXCEPTION: IN A SINGLE-FAMILY DWELLING, MAKE-UP AIR IS
 NOT REQUIRED FOR RANGE HOOD EXHAUST SYSTEMS CAPABLE OF
 EXHAUSTING:
  
 (A)FOUR HUNDRED CUBIC FEET PER MINUTE OR LESS; OR
  
 (B)MORE THAN 400 CUBIC FEET PER MINUTE BUT NO MORE THAN
 800 CUBIC FEET PER MINUTE IF THERE ARE NO GRAVITY VENT
 APPLIANCES WITHIN THE CONDITIONED LIVING SPACE OF THE
 STRUCTURE.
  
 M1503.4.1 LOCATION.
 KITCHEN EXHAUST MAKEUP AIR SHALL BE DISCHARGED INTO THE
 SAME ROOM IN WHICH THE EXHAUST SYSTEM IS LOCATED OR
 INTO ROOMS OR DUCT SYSTEMS THAT COMMUNICATE THROUGH ONE
 OR MORE PERMANENT OPENINGS WITH THE ROOM IN WHICH SUCH
 EXHAUST SYSTEM IS LOCATED. SUCH PERMANENT OPENINGS
 SHALL HAVE A NET CROSS-SECTIONAL AREA NOT LESS THAN THE
 REQUIRED AREA OF THE MAKEUP AIR SUPPLY OPENINGS.
  
  
 CHRIS MONTELLO
 561-805-6733
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-07-02 Cont ID  
Sent By thunt Date 2018-07-02 Time 15:41 Rev Time 0.00
Received By thunt Date 2018-07-02 Time 15:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-07 Cont ID  
Sent By thunt Date 2018-06-07 Time 14:21 Rev Time 0.00
Received By thunt Date 2018-06-07 Time 14:21 Sent To  
Notes
2018-06-07 14:24:4106/07/2018 1ST PLUMBING REVIEW**DENIED**
  
 1) PROVIDE AN EXISTING FLOOR PLAN. FBC 107.2.1
  
 2) PROVIDE MAKE UP AIR CALCULATIONS FOR THE DRYER. FBC
 R G2407.1
  
 3) CABANA BATH HAVE AN AAV ON ITS OWN BUILDING DRAIN IS
 NOT PERMITTED AND SHALL HAVE 1 VENT THAT ENTENDS
 THROUGH THE ROOF. FBC R P3102.1
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-06-29 Cont ID  
Sent By awooten Date 2018-06-29 Time   Rev Time 0.00
Received By awooten Date 2018-06-29 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-05-22 Cont ID  
Sent By AW Date 2018-05-22 Time 15:55 Rev Time 0.00
Received By awooten Date 2018-05-21 Time 16:32 Sent To  
Notes
2018-05-22 15:46:13*******************************************************
 ***ZONING REVIEW***************************************
 ***************
  
 IS THE FOOT PRINT OF THE BUILDING CHANGING?
  
 PLEASE PROVIDE A SURVEY AND AN EXISTING FLOOR PLAN.
  
 FURTHER COMMENTS MAY COME FROM ADDITIONAL REVIEW.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 561-822-1449
 [email protected]
  