Plan Review Details - Permit 18050622
Plan Review Stops For Permit 18050622 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-06-08 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-06-08 |
Time |
05:46 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-06-08 |
Time |
05:30 |
Sent To |
I |
|
Notes |
2018-06-08 05:46:21 | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-05-23 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-05-23 |
Time |
06:28 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-05-23 |
Time |
05:50 |
Sent To |
I |
|
Notes |
2018-05-23 06:27:14 | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. #12AWG FOR AN APPROX 300FT RUN IS INSUFFICIENT FOR | | ALLOWABLE VOLTAGE DROP. INDICATE VOLTAGE DROP | | COMPLIANCE WITH FBC ENERGY CONSERVATION. PROVIDE | | CORRECTIONS TO WIRE SIZE/PANEL SCHEDULE AND VOLTAGE | | DROP CALCULATION AS PER FBC EC C405.7.3 NEC 210.10(A1) | | I.N. #4 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-08 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-06-08 |
Time |
05:46 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-06-05 |
Time |
13:29 |
Sent To |
I |
|
Notes |
2018-06-06 13:29:32 | RESUB ROUTED TO FGIAQUIN |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-05-23 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-05-23 |
Time |
06:28 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-05-14 |
Time |
12:36 |
Sent To |
|
|
Notes |
2018-05-15 12:36:28 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-05-16 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2018-05-16 |
Time |
|
Sent To |
E |
|
Notes |
2018-05-16 16:46:53 | ZONING REVIEW N/A, PROVIDED NO TREES ARE REMOVED FROM | | PROPERTY AS A RESULT OF THE INSTALLATION OF LIGHT | | POLES. | | | | M. CRUZ | | ASSOCIATE PLANNER | | 561-822-1442 | | [email protected] |
|
|
|