Plan Review Stops For Permit 18050041 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-08-21 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-08-21 |
Time |
11:42 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2018-08-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-08-08 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-08-08 |
Time |
14:43 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-07-27 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-07-27 |
Time |
12:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-27 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-06-27 |
Time |
12:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-05 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-06-05 |
Time |
12:58 |
Sent To |
|
|
Notes |
2018-06-05 14:53:36 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SUBMITTAL NOW HAS TWO PLANS FROM DIFFERENT SIGN | | COMPANIES. PLEASE REMOVE DESIGN THAT DOES NOT COMPLY | | WITH THIS SUBMITTAL. | | 2. ADDRESS BLDG. REVIEW COMMENTS FROM 1ST REVIEW AND | | RE-SUBMIT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-05-14 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-05-14 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-14 |
Time |
10:56 |
Sent To |
|
|
Notes |
2018-05-14 11:04:14 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE WIND DESIGN LOADS FOR PROPOSED SIGN. | | FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | | | 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | STRUCTURE: | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | 1609.3.1. | | 2. RISK CATEGORY. | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | THAN ONE WIND EXPOSURE IS UTILIZED. | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | M2). | | | | 2. PROVIDE FASTENER SCHEDULE BASED ON WIND DESIGN DATA | | AND EXISTING WALL TYPE. | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | | | 3. VALUE APPEARS LOW FOR PROPOSED SCOPE OF WORK. | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | CONTRACTOR WOULD PROVIDE. | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | RENTAL TO VERIFY VALUE. | | | | CITY OF WPB CHPT. 1 ? VALUE | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | BUILDING OFFICIAL. | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | | | | 2018-05-10 16:17:24 | FAILED- STAMPED APPROVED PLANS OR A LETTER FROM THE PB | | OUTLETS REQUIRED. | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-08-21 |
Time |
06:00 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-08-21 |
Time |
05:59 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2018-08-06 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-08-06 |
Time |
06:34 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-08-06 |
Time |
06:29 |
Sent To |
B |
|
Notes |
2018-08-06 06:33:36 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 4X THE PLAN REVIEW FEE HAS BEEN ADDED TO THIS FOR THE | | SAME DEFECIENCIES ON PLAN REVIEW DOCUMENTS FOR 6 | | REVIEWS AS PER F.S. 553.802B | | | | 1. 6TH PLAN REVIEW WITH SAME DEFICIENCIES. | | | | 2. HIGH VOLTAGE AND LOW VOLTAGE TOGETHER IN J-BOX. | | 725.136B NEC | | | | 3. DISCONNECT REQUIRED WITHIN SIGHT OF SIGN THAT | | DISCONNECTS THE BRANCH CIRCUIT/FEEDER CONDUCTORS BEFORE | | IT ENTERS THE SIGN. NEC 600.6A1 | | | | 4. DUE TO THE DISCONNECT REQUIREMENTS OF 600.6A(1) NEC | | AN ELEC SUB-PERMIT CAN'T BE ISSUED TO AN ES LICENSE | | HOLDER BECAUSE IT IS OUT OF THE SCOPE OF WORK FOR THEIR | | LICENSE. PLEASE HAVE LICENSED ELECTRICIAN PULL | | SUB-ELECTRICAL PERMIT. | | | | SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C. | | 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN | | SPECIALTY CONTRACTOR) | | | | THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL | | FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION, | | INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF | | ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF | | CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR | | ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR | | TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER | | THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE | | REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE | | BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY | | STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN | | TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250) | | VOLTS MAXIMUM. | | | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2018-07-25 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-07-25 |
Time |
06:35 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-07-25 |
Time |
06:12 |
Sent To |
B |
|
Notes |
2018-07-25 06:24:37 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. 5TH PLAN REVIEW WITH SAME DEFICIENCIES. THERE WILL | | BE NO FURTHER PLAN REVIEWS OF THIS PERMIT (FOR | | ELECTRICAL) UNTIL I HAVE SPOKEN TO EITHER THE QUALIFIER | | FOR FERRIGN SIGNS OR THE ENGINEER OF RECORD FOR THIS | | PROJECT. PLEASE CONTACT ME DIRECTLY ON MY CELL PHONE | | 561-657-1653 | | | | 2. HIGH VOLTAGE AND LOW VOLTAGE TOGETHER IN J-BOX. | | 725.136B NEC | | | | 3. DISCONNECT REQUIRED AS PER NEC 600.6A1 | | | | 4. DUE TO THE DISCONNECT REQUIREMENTS OF 600.6A(1) NEC | | AN ELEC SUB-PERMIT CAN'T BE ISSUED TO AN ES LICENSE | | HOLDER BECAUSE IT IS OUT OF THE SCOPE OF WORK FOR THEIR | | LICENSE. | | | | SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C. | | 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN | | SPECIALTY CONTRACTOR) | | | | THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL | | FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION, | | INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF | | ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF | | CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR | | ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR | | TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER | | THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE | | REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE | | BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY | | STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN | | TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250) | | VOLTS MAXIMUM. | | | | 5. THERE IS A NOTE ON THE PLAN THAT STATES "TIME CLOCK | | IS EXISTING" TIME CLOCK MUST STILL CONFORM TO FBC CE | | 405.2.4 (ASTRONOMICAL TIME CLOCK NEEDED) | | | | 6. SIGNATURE AND SEAL ON PLAN IS PHOTO COPIED. NOT | | CONSIDERED TO BE SIGNED AND SEALED. | | | | PHYSICALLY TRANSMITTED DOCUMENTS REQUIRE THAT THE | | LICENSEE CREATE BY HAND AN ORIGINAL OF THE LICENSEE?S | | SIGNATURE. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | COPIED IMAGE OF THE LICENSEE?S SIGNATURE IS NOT ALLOWED | | ON PHYSICALLY TRANSMITTED DOCUMENTS. | | CHAPTER 61G15-23.003(1), F.A.C., THE LICENSEE SHALL | | SIGN BY HAND AN ORIGINAL OF THE LICENSEE?S SIGNATURE ON | | EACH PAGE REQUIRED TO BE SEALED. A SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED. | | | | AS FOR CREATING THE SEAL, PHYSICALLY TRANSMITTED | | DOCUMENTS ARE ALLOWED TO BE EMBOSSED, SEALED USING A | | WET STAMP, OR CONTAIN A DIGITALLY CREATED SEAL (AS PART | | OF THE BORDER). IN EACH OF THESE CASES THE SEAL IS TO | | PARTIALLY OVERLAP THE LICENSEE?S SIGNATURE SUCH THAT | | THE SIGNATURE IS NOT MADE ILLEGIBLE. | | CHAPTER 61G15-23.003(2), F.A.C., THE LICENSEE MUST THEN | | USE A WET SEAL, A DIGITALLY CREATED SEAL, OR AN | | EMBOSSING SEAL PLACED PARTIALLY OVERLAPPING THE | | LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE | | SEALED. THE PLACEMENT OF THE SEAL SHALL NOT RENDER THE | | SIGNATURE ILLEGIBLE. | | | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2018-07-13 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-07-13 |
Time |
06:26 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-07-13 |
Time |
05:36 |
Sent To |
I |
|
Notes |
2018-07-13 06:25:55 | SAME VIOLATIONS AS PREVIOUS PLAN REVIEW. PLEASE SEE | | COMMENTS BELOW. | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLAN STILL DOES NOT MEET DISCONNECT REQUIRMENTS OF | | 600.6A(1) NEC. | | | | 2. DUE TO THE DISCONNECT REQUIREMENTS OF 600.6A(1) NEC | | AN ELEC SUB-PERMIT CAN'T BE ISSUED TO AN ES LICENSE | | HOLDER BECAUSE IT IS OUT OF THE SCOPE OF WORK FOR THEIR | | LICENSE. | | | | SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C. | | 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN | | SPECIALTY CONTRACTOR) | | THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL | | FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION, | | INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF | | ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF | | CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR | | ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR | | TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER | | THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE | | REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE | | BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY | | STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN | | TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250) | | VOLTS MAXIMUM. | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2018-06-24 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-06-24 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-06-24 |
Time |
07:51 |
Sent To |
B |
|
Notes |
2018-06-24 08:16:11 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLAN STILL DOES NOT MEET DISCONNECT REQUIRMENTS OF | | 600.6A(1) NEC. | | | | 2. DUE TO THE DISCONNECT REQUIREMENTS OF 600.6A(1) NEC | | AN ELEC SUB-PERMIT CAN'T BE ISSUED TO AN ES LICENSE | | HOLDER BECAUSE IT IS OUT OF THE SCOPE OF WORK FOR THEIR | | LICENSE. | | | | SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C. | | 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN | | SPECIALTY CONTRACTOR) | | THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL | | FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION, | | INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF | | ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF | | CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR | | ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR | | TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER | | THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE | | REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE | | BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY | | STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN | | TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250) | | VOLTS MAXIMUM. | | | | 3. CONTRACT DOES NOT INCLUDE ALL FEES. PROCUREMENT FEE, | | "FINAL INSPECTION" FEE, AND ENGINEERING FEES ARE TO BE | | INCLUDED IN PRICE. VALUE HAS BEEN UPDATED TO 2650$. FBC | | 109.3 | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-06-04 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-06-04 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-06-04 |
Time |
06:56 |
Sent To |
B |
|
Notes |
2018-06-04 07:22:29 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. INITIAL PLAN FAILED DUE TO THE NEED FOR A DISCONNECT | | AND VALUE BEING TOO LOW. NOW A NEW PLAN HAS BEEN | | SUBMITTED SEPARATELY WITH A DIFFERENT SIGN CONTRACTOR | | NAME (RAMSAY) INSTEAD OF FERRIN SIGNS AS IS ON PERMIT | | APPLICATION. CORRECT CONFLICTING ERRORS ON PLANS. | | CANNOT HAVE 2 DIFFERENT PLANS, ZONING AND BUILDING MUST | | REVIEW NEW PLAN SUBMITTED. | | | | 2. NEW PLAN SUBMITTED IS NOT SIGNED. ELECTRICAL PLAN IS | | REQUIRED TO BE DESIGNED AND SIGNED/SEALED BY A DESIGN | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. | | PROVIDE CORRECTION. FS 471.003(2)(H); 471.025; WPB FBC | | 107.1 | | | | 3. VALUE TOO LOW, PROVIDE COPY OF SIGNED CONTRACT WITH | | SCOPE AND VALUE OF WORK, TO INCLUDE ALL MATERIALS AND | | LABOR. FBC 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-05-11 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-05-11 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-05-11 |
Time |
15:20 |
Sent To |
B |
|
Notes |
2018-05-11 15:22:39 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | SIGN NEEDS A DISCONNECT IN ACCORDANCE WITH 600.6(A)(1) | | | | VALUE FOR SIGN TO LOW. | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | WORK, ARCHITECTURAL | | AND DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | INCLUDE | | THE LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST | | ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS | | PUBLISHED | | BY INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | PLEASE SUBMIT A SIGNED CONTRACT FOR TOTAL SIGN | | INSTALLATION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2018-08-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-08-21 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-08-09 |
Time |
11:19 |
Sent To |
|
|
Notes |
2018-08-10 11:19:37 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2018-08-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-08-08 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-07-30 |
Time |
14:07 |
Sent To |
|
|
Notes |
2018-07-31 14:08:05 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-07-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-07-27 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-07-18 |
Time |
14:46 |
Sent To |
I |
|
Notes |
2018-07-19 14:46:59 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-07-13 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-07-13 |
Time |
06:26 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-07-11 |
Time |
16:00 |
Sent To |
|
|
Notes |
2018-07-12 16:00:23 | RESUB ROUTED TO FGIAQUINTO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-06-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-27 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-06-13 |
Time |
14:30 |
Sent To |
I |
|
Notes |
2018-06-14 14:30:51 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-05 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-22 |
Time |
13:05 |
Sent To |
I |
|
Notes |
2018-05-23 13:05:38 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-05-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-05-14 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-01 |
Time |
10:17 |
Sent To |
I |
|
Notes |
2018-05-02 10:17:35 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
2018-08-16 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-08-16 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-08-16 |
Time |
16:14 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2018-08-02 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-08-02 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-08-01 |
Time |
16:59 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2018-07-23 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-07-23 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-07-23 |
Time |
17:12 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-06-19 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-06-19 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-06-19 |
Time |
09:23 |
Sent To |
E |
|
Notes |
2018-06-19 09:24:42 | WRITTEN APPROVAL FROM PALM BEACH OUTLETS WAS PROVIDED | | BY APPLICANT. | | | | MAGGIE CRUZ | | ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: 561-822-1442 | | E-MAIL: [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-05-25 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2018-05-25 |
Time |
|
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-05-10 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-05-10 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-05-10 |
Time |
16:15 |
Sent To |
E |
|
Notes |
2018-05-10 16:18:28 | FAILED- STAMPED APPROVED PLANS OR A LETTER FROM THE PB | | OUTLETS REQUIRED. | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] |
|
|