Plan Review Details - Permit 18050035
Plan Review Stops For Permit 18050035
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-05-14 Cont ID  
Sent By rmcdouga Date 2018-05-14 Time 11:44 Rev Time 0.00
Received By rmcdouga Date 2018-05-14 Time 11:40 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-06-11 Cont ID  
Sent By ppetty Date 2018-06-11 Time 12:35 Rev Time 0.00
Received By ppetty Date 2018-06-11 Time 12:35 Sent To P
Notes
2018-06-11 12:35:47CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: OK, SEE COMMENTS BELOW.
  
 1. OK
 2. OK
 3. OK
 4. OK
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER CHIEF ELECTRICAL INSPECTOR
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-05-10 Cont ID  
Sent By jpearson Date 2018-05-10 Time 15:15 Rev Time 0.00
Received By jpearson Date 2018-05-10 Time 15:15 Sent To  
Notes
2018-05-10 15:15:21CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1,
 E3609.3; WPB FBC 107.2.1
 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND GFCI PROTECTION WHERE APPLICABLE TO COMPLY WITH
 CODE. NEC 210.8, 215.5, 408.4; WPB FBC 107.3.5; FBC RE
 E3706.2, E3902
 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
 4. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC
 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-05-14 Cont ID  
Sent By tklarge Date 2018-05-14 Time 03:28 Rev Time 0.00
Received By tklarge Date 2018-05-14 Time 02:21 Sent To  
Notes
2018-05-14 03:29:01THIS POOL IS EQUIPPED WITH AN ELECTRIC HEAT PUMP.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-06-30 Cont ID  
Sent By tklarge Date 2018-06-30 Time 04:37 Rev Time 0.00
Received By tklarge Date 2018-06-25 Time 14:15 Sent To  
Notes
2018-06-26 14:15:26RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-18 Cont ID  
Sent By tklarge Date 2018-06-18 Time 12:36 Rev Time 0.00
Received By tklarge Date 2018-06-05 Time 13:38 Sent To  
Notes
2018-06-06 13:39:03RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-05-14 Cont ID  
Sent By rmcdouga Date 2018-05-14 Time 11:44 Rev Time 0.00
Received By rmcdouga Date 2018-05-01 Time 10:24 Sent To  
Notes
2018-05-02 10:24:49ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-06-30 Cont ID  
Sent By tklarge Date 2018-06-30 Time 04:37 Rev Time 0.00
Received By tklarge Date 2018-06-30 Time 04:25 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-06-18 Cont ID  
Sent By tklarge Date 2018-06-18 Time 12:35 Rev Time 0.00
Received By tklarge Date 2018-06-18 Time 12:17 Sent To I
Notes
2018-06-18 12:35:091) SHT. 2 OF 3 - ELECTRICAL SCHEMATIC DIAGRAM SHOWS AN
 OPTIONAL GAS HEATER BUT THE PROJECT SPECIFIC DETAILS ON
 SHT.1 OF 3 REFERS TO AN ELECTRIC HEATER. CLARIFY.2ND
 REQUEST
 2) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS FOR THE MAIN DRAINS. WPB AMEND. TO FBC
 SEC. 107.2.1.2ND REQUEST
 3) SHT.1 OF 3 - GENERAL NOTE #3 REFERS TO THE 2014 FBC.
 REVISE NOTE TO READ 2017 FBC.2ND REQUEST.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-805-6692
 [email protected]
  
  
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-05-14 Cont ID  
Sent By tklarge Date 2018-05-14 Time 03:28 Rev Time 0.00
Received By tklarge Date 2018-05-14 Time 02:27 Sent To  
Notes
2018-05-14 03:27:581) SHT.1 OF 3 - GENERAL NOTE #6 - STATES "DISPOSAL OF
 WATER WILL CONFORM TO FBC 2017 E4204." THIS CODE
 SECTION IS FROM THE 2017 FBC-RESIDENTIAL CODE AND THIS
 SECTION IS FOR POOL BONDING. CLARIFY.
 2) SHT. 2 OF 3 - ELECTRICAL SCHEMATIC DIAGRAM SHOWS AN
 OPTIONAL GAS HEATER BUT THE PROJECT SPECIFIC DETAILS ON
 SHT.1 OF 3 REFERS TO AN ELECTRIC HEATER. CLARIFY.
 3) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS FOR THE MAIN DRAINS. WPB AMEND. TO FBC
 SEC. 107.2.1.
 4) IT APPEARS THAT THE TOTAL DYNAMIC HEAD CALCULATIONS
 WERE BASED ON THE MAXIMUM FLOW RATE OF THE PUMP.SUBMIT
 TOTAL DYNAMIC HEAD CALCULATIONS FOR THE MAXIMUM SYSTEM
 FLOW. THE MAXIMUM FLOW OF THE PUMP FROM ITS PUMP CURVE
 IS NO LONGER ALLOWED TO BE USED IN DETERMINING MAXIMUM
 SYSTEM FLOW RATE PER ANSI/APSP/ICC 7 ? 2013 SECS.
 4.4.9, 4.4.9.1. THE 2013 EDITION ADDRESSES FLOW RATE IN
 GALLONS PER MINUTE (GPM). IT REQUIRES THAT MAXIMUM
 SYSTEM FLOW RATE DOES NOT EXCEED THE LISTED MAXIMUM
 FLOW RATE OF THE SUCTION OUTLET FITTING ASSEMBLY (DRAIN
 COVER).
 5) SHT.1 OF 3 - GENERAL NOTE #3 REFERS TO THE 2014 FBC.
 REVISE NOTE TO READ 2017 FBC.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-805-6692
 [email protected]
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2018-05-07 Time   Rev Time  
Received By   Date 2018-05-07 Time   Sent To B
Notes
***NONE***