Plan Review Stops For Permit 18041158 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-07-26 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-07-26 |
Time |
08:39 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-05-03 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-05-03 |
Time |
09:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-07-26 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-07-26 |
Time |
09:28 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-05-10 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-05-10 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-05-10 |
Time |
13:00 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2018-07-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-07-25 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-07-25 |
Time |
13:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2018-06-29 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-29 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-29 |
Time |
06:24 |
Sent To |
I |
|
Notes |
2018-06-29 07:46:08 | 1) THE EXISTING GAS PLANS ON FILE AT THE CITY SHOW A | | SUMMER KITCHEN WITH A 55,000 BTU LOAD BUT THIS IS NOT | | SHOWN ON THE SUBMITTED GAS DRAWING. REVISE THE GAS | | DRAWING TO REFLECT THE SUMMER KITCHEN AND REVISE THE | | TOTAL BTU LOAD ON THE GAS DOCUMENTS. WPB AMEND. TO FBC | | SEC. 107.2.1, 2017 FBC-FUEL GAS SEC.401.3, 401.4. | | 2) THE SHUTOFF VALVE ON THE 3/4 INCH EXISTING LINE INTO | | THE STRUCTURE SHALL BE LOCATED IMMEDIATELY AHEAD OF THE | | REGULATOR. 2017 FBC-FUEL GAS SEC.409.4. | | 3) SHOW THE DISTANCE FROM THE MP REGULATOR FOR THE | | EXISTING LINE INTO THE STRUCTURE TO THE MOST REMOTE GAS | | OUTLET ON THAT SECTION. THIS DISTANCE WILL DETERMINE | | THE PIPE SIZING.THE EXISTING PLANS ON FILE SHOW THE | | LONGEST RUN AS 100 FEET. | | 4) THE EXISTING PLANS ON FILE AT THE CITY SHOW THE PIPE | | SIZE AT THE METER OUTLET AS 1 INCH AND THE SUBMITTED | | PLAN SHOWS 3/4 INCH. CLARIFY. | | 5) SHOW THE PIPE SIZE OF THE PE ON THE GAS PLAN. WPB | | AMEND. TO FBC SEC. 107.2.1. | | 6) SHOW THE DISTANCE FROM THE METER TO THE REGULATOR | | FOR THE EXISTING LINE INTO THE STRUCTURE. | | | | NOTE: THE SAME GAS DRAWING THAT WAS REJECTED ON THE | | REVIEW OF 6/3 HAS BEEN RESUBMITTED AND REJECTED AGAIN | | BECAUSE NONE OF THE CORRECTIONS WERE MADE. RESUBMITTAL | | OF THESE PLANS WILL REQUIRE PAYMENT OF 4X THE PLAN | | REVIEW FEE IN ACCORDANCE WITH FL. STATUTE 553.80 (2) | | (B). | | | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2018-06-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-03 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-03 |
Time |
13:19 |
Sent To |
I |
|
Notes |
2018-06-03 13:55:33 | 1) THE EXISTING GAS PLANS ON FILE AT THE CITY SHOW A | | SUMMER KITCHEN WITH A 55,000 BTU LOAD BUT THIS IS NOT | | SHOWN ON THE SUBMITTED GAS DRAWING. REVISE THE GAS | | DRAWING TO REFLECT THE SUMMER KITCHEN AND REVISE THE | | TOTAL BTU LOAD ON THE GAS DOCUMENTS. WPB AMEND. TO FBC | | SEC. 107.2.1, 2017 FBC-FUEL GAS SEC.401.3, 401.4. | | 2) THE SHUTOFF VALVE ON THE 3/4 INCH EXISTING LINE INTO | | THE STRUCTURE SHALL BE LOCATED IMMEDIATELY AHEAD OF THE | | REGULATOR. 2017 FBC-FUEL GAS SEC.409.4. | | 3) SHOW THE DISTANCE FROM THE MP REGULATOR FOR THE | | EXISTING LINE INTO THE STRUCTURE TO THE MOST REMOTE GAS | | OUTLET ON THAT SECTION. THIS DISTANCE WILL DETERMINE | | THE PIPE SIZING.THE EXISTING PLANS ON FILE SHOW THE | | LONGEST RUN AS 100 FEET. | | 4) THE EXISTING PLANS ON FILE AT THE CITY SHOW THE PIPE | | SIZE AT THE METER OUTLET AS 1 INCH AND THE SUBMITTED | | PLAN SHOWS 3/4 INCH. CLARIFY. | | 5) SHOW THE PIPE SIZE OF THE PE ON THE GAS PLAN. WPB | | AMEND. TO FBC SEC. 107.2.1. | | 6) SHOW THE DISTANCE FROM THE METER TO THE REGULATOR | | FOR THE EXISTING LINE INTO THE STRUCTURE. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2018-05-15 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-05-15 |
Time |
05:59 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-05-15 |
Time |
05:18 |
Sent To |
I |
|
Notes |
2018-05-15 05:26:00 | | | 1) SHOW THE TYPE OF PIPE AND PIPE SIZE AT THE OUTLET OF | | THE 2 PSI METER . WPB AMEND. TO FBC SEC. 107.2.1. | | 2) SHOW THE PIPE SIZE OF THE SECTION OF PIPE TO THE | | REGULATOR SERVING THE EXISTING GAS LOAD.WPB AMEND. TO | | FBC SEC. 107.2.1. | | 3) SHOW THE TYPE OF PIPE AND PIPE SIZE DOWNSTREAM OF | | THE REGULATOR FOR THE EXISTING GAS LOADS AND NOTE THE | | DISTANCE FROM THIS REGULATOR TO THE FURTHEST OUTLET ON | | THAT SYSTEM.WPB AMEND. TO FBC SEC. 107.2.1. | | 4) A LISTED SHUTOFF VALVE IS REQUIRED IMMEDIATELY AHEAD | | OF THE MP REGULATOR FFOR THE EXISTING LOADS.. 2017 FBCR | | SEC. G2420.4. | | 5) SPECIFY ON THE GAS DRAWING HOW THE 3/4 INCH | | GALVANIZED PIPE IS GOING TO BE INSTALLED. ABOVE-GROUND | | PIPING OUTDOORS SHALL COMPLY WITH 2017 FBCR | | SEC.G2415.9, G2415.11. | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE FLEX | | CONNECTOR FOR THE GENERATOR. THE FLEX CONNECTOR SHALL | | BE APPROVED TO FLOW THE MAXIMUM BTU LOAD FOR THE | | GENERATOR. 2017 FBCR SEC. G2422.1 (8). | | 7) THE SEDIMENT TRAP AS DRAWN DOES NOT COMPLY WITH 2017 | | FBCR SEC.G2419.4. | | 8) LIST THE EXISTING GAS FIXTURES ON THE PLAN AND THE | | CORRESPONDING BTU LOAD FOR EACH APPLIANCE. WPB AMEND. | | TO FBC SEC .107.2.1, 2017 FBC-FUEL GAS SEC.402.1. | | 9) SUBMIT CLEAR AND LEGIBLE SPECIFICATIONS FOR THE | | GENERATOR. SOME AREAS ON THE SHEETS CANNOT BE READ. WPB | | AMEND. TO FBC SEC. 1107.2.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-07-26 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-07-16 |
Time |
14:34 |
Sent To |
|
|
Notes |
2018-07-17 14:34:43 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-06-29 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-29 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-21 |
Time |
13:13 |
Sent To |
I |
|
Notes |
2018-06-22 13:14:18 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-03 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-05-29 |
Time |
13:58 |
Sent To |
|
|
Notes |
2018-05-30 13:58:22 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-05-15 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-05-15 |
Time |
06:00 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-04-25 |
Time |
13:29 |
Sent To |
|
|
Notes |
2018-04-26 13:29:33 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2018-07-23 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-07-23 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-07-23 |
Time |
08:40 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-06-26 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-06-26 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-06-26 |
Time |
15:54 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-05-31 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-05-31 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-05-31 |
Time |
16:40 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-05-02 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-05-02 |
Time |
12:12 |
Sent To |
G |
|
Notes |
|
|