Plan Review Stops For Permit 18040925 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-05-03 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-05-03 |
Time |
11:50 |
Sent To |
G |
|
Notes |
2018-05-03 11:51:22 | ELECTRICAL INSPECTOR TO VERIFY THE SLAB AT ELECTRICAL | | FINAL JLEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-05-03 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-05-03 |
Time |
11:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2018-06-11 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-06-11 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-06-11 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-05 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-05 |
Time |
06:28 |
Sent To |
I |
|
Notes |
2018-06-05 06:33:31 | 1)THE GAS DRAWING REFERENCES GAS SIZING TABLE 402.4 | | (36) WHICH IS FOR A 2 PSI SYSTEM BUT THE GAS DRAWING | | DOES NOT SHOW THE 2 PSI SYSTEM. THE ONLY REFERENCE IS | | TO 10 PSI SYSTEM. CLARIFY. | | | | 2) PROVIDE DETAILS FOR THE ANCHORING OF THE LP TANK TO | | PREVENT FLOTATION.PROVIDE THE SIZE OF THE HOLD-DOWN | | CABLES/STRAPS FOR THE TANK AND THE TYPE AND LENGTH OF | | GROUND ANCHORS TO BE INSTALLED TO PREVENT FLOTATION. | | NFPA 58 SEC. 6.6.1.6. | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALLATION | | INSTRUCTIONS FOR BOTH TYPE OF REGULATORS. 2017 FBC-FUEL | | GAS SEC. 410.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2018-05-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-05-21 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-05-21 |
Time |
06:30 |
Sent To |
|
|
Notes |
2018-05-21 09:22:35 | 1)THE GAS DRAWING REFERENCES GAS SIZING TABLE 402.4 | | (36) WHICH IS FOR A 2 PSI SYSTEM BUT THE GAS DRAWING | | DOES NOT SHOW THE 2 PSI SYSTEM. THE ONLY REFERENCE IS | | TO 10 PSI SYSTEM. CLARIFY. | | | | 2) PROVIDE THE SIZE OF THE HOLD-DOWN CABLES/STRAPS FOR | | THE TANK AND THE TYPE AND LENGTH OF GROUND ANCHORS TO | | BE INSTALLED TO PREVENT FLOTATION. NFPA 58 SEC. | | 6.6.1.6. | | | | 3) SUBMIT ALL THE PAGES FOR THE INSTALLATION | | INSTRUCTIONS FOR THE REGULATORS. 2017 FBC-FUEL GAS SEC. | | 410.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-06-11 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-06-11 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-06-08 |
Time |
11:43 |
Sent To |
I |
|
Notes |
2018-06-11 11:43:57 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-05 |
Time |
06:44 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-05-30 |
Time |
15:21 |
Sent To |
|
|
Notes |
2018-05-31 15:22:10 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-05-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-05-21 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-04-19 |
Time |
13:10 |
Sent To |
I |
|
Notes |
2018-04-20 13:10:40 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-06-01 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-06-01 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-06-01 |
Time |
16:32 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-05-01 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-05-01 |
Time |
12:03 |
Sent To |
|
|
Notes |
2018-05-01 12:14:03 | 5/1/18- FAILED | | THE REAR SETBACK FOR THE GENERATOR FROM THE PROPERTY | | LINE IS 11 FEET. | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] |
|
|