Plan Review Stops For Permit 18040834 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-06-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-07 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-07 |
Time |
15:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-03 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-03 |
Time |
18:40 |
Sent To |
|
|
Notes |
2018-05-03 18:41:53 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1609, ALTHOUGH CALCULATIONS MAY SHOW THAT | | THREE FASTENERS ARE ADEQUATE, IT DOES NOT APPEAR | | ADEQUATE BASED ON THE SHAPE OF THE SIGN. ALSO, LOCATION | | OF FASTENERS WAS NOT SPECIFIED BUT IT APPEARS THAT THIS | | MAKES A DIFFERENCE. | | | | EITHER PROVIDE A PLAN SHOWING LOCATION OF FASTENERS | | (AND ADD ADDITIONAL AS NEEDED FOR THE SHAPE OF THE | | LETTERS), OR CONTACT ME TO DISCUSS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-06-01 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-06-01 |
Time |
07:15 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-06-01 |
Time |
07:04 |
Sent To |
B |
|
Notes |
2018-06-01 07:15:19 | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-05-03 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-05-03 |
Time |
06:55 |
Sent To |
B |
|
Notes |
2018-05-03 07:01:04 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR THE | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-07 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-22 |
Time |
13:17 |
Sent To |
|
|
Notes |
2018-05-30 14:42:23 | SENT TO LAURA MARCHANT 5/30/18 | 2018-05-23 13:17:45 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-03 |
Time |
18:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-18 |
Time |
10:23 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-05-30 |
|
|
Cont ID |
|
Sent By |
mc to aa |
Date |
2018-05-30 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2018-05-30 |
Time |
14:39 |
Sent To |
E |
|
Notes |
2018-05-30 14:42:02 | MEETS CURRENT CODE REQUIREMENTS -UP TO TWO BUILDING | | IDENTITY SIGNS, WITH THE SAME IDENTITY, SHALL BE | | ALLOWED ON BUILDINGS THREE OR MORE STORIES IN HEIGHT. | | ONLY ONE BUILDING IDENTITY SIGN SHALL BE ALLOWED PER | | FACADE. SUCH SIGNS SHALL NOT EXCEED A TOTAL SIGN FACE | | OF 100 SQUARE FEET EACH. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-03 |
Time |
18:42 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2018-05-01 |
Time |
11:57 |
Sent To |
E |
|
Notes |
2018-05-01 11:58:43 | 1. MAXIMUM SIZE ALLOWED FOR A SIGN IS 100 SF. | | 2. INFORMATION PROVIDED IN DRAWINGS HAVE CONFLICTING | | DIMENSIONS FOR PROPOSED SIGN. PLEASE CLARIFY WHAT IS | | THE EXACT SIZE OF THE PROPOSED SIGN. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|