Plan Review Stops For Permit 18040797 |
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2018-09-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-24 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-24 |
Time |
08:33 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2018-09-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-05 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-05 |
Time |
07:53 |
Sent To |
|
|
Notes |
2018-09-05 07:52:58 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. CORRECTED. | | 2. WILL CAMERAS HAVE HIGH VOLTAGE WIRING IN ADDITION TO | | LOW VOLTAGE WIRING? PROVIDE CLARIFICATION. FBC 107.2.1 | | (BASED ON COMMENT RESPONSE, PROVIDE DETAIL OF | | SEPARATION FOR LOW VOLTAGE WIRING FROM POWER WIRING. | | NEC 725.136)(3RD REVIEW: DETAIL PROVIDED SHOWS WHAT | | APPEARS TO BE A CORD FEEDING THE 120 VOLT SUPPLY. CORD | | IS NOT PERMITTED AS A SUBSTITUTE FOR FIXED WIRING | | METHODS. PROVIDE CORRECTION. NEC 400.8) | | 3. CORRECTED. | | 4. CORRECTED. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-06-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-06-29 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-06-29 |
Time |
15:35 |
Sent To |
|
|
Notes |
2018-06-29 15:35:33 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. PROVIDE GRAPH/CALCULATION OF EXTERIOR LIGHTING POWER | | ALLOWANCES PER THE FBC ENERGY CONSERVATION IN RELATION | | TO THE CONNECTED EXTERIOR LIGHTING PROPOSED TO COMPLY | | WITH CODE. FBC EC C405.5.1 (COMMENT RESPONSE STATES | | THAT THIS CODE REFERS TO INTERIOR LIGHTING. I'M NOT | | SURE WHICH YEAR CODE YOU ARE LOOKING AT, BUT IN THE | | 2017 FBC ENERGY CONSERVATION, THIS SECTION IS FOR | | EXTERIOR LIGHTING. IT APPEARS THAT YOU ARE REQUESTING | | EXEMPTION THAT IS USED FOR THEME ELEMENTS IN | | AMUSEMENT/THEME PARKS, WHICH DOES NOT APPLY TO THIS | | SUBMITTAL. PROVIDE AS PREVIOUSLY REQUESTED. YOU ARE | | WELCOME TO DISCUSS THIS WITH THE BUILDING OFFICIAL IF | | YOU DISAGREE.) | | 2. WILL CAMERAS HAVE HIGH VOLTAGE WIRING IN ADDITION TO | | LOW VOLTAGE WIRING? PROVIDE CLARIFICATION. FBC 107.2.1 | | (BASED ON COMMENT RESPONSE, PROVIDE DETAIL OF | | SEPARATION FOR LOW VOLTAGE WIRING FROM POWER WIRING. | | NEC 725.136) | | 3. CORRECTED. | | 4. CORRECTED. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-05-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-05-05 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-05-05 |
Time |
11:34 |
Sent To |
|
|
Notes |
2018-05-05 11:34:33 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE GRAPH/CALCULATION OF EXTERIOR LIGHTING POWER | | ALLOWANCES PER THE FBC ENERGY CONSERVATION IN RELATION | | TO THE CONNECTED EXTERIOR LIGHTING PROPOSED TO COMPLY | | WITH CODE. FBC EC C405.5.1 | | 2. WILL CAMERAS HAVE HIGH VOLTAGE WIRING IN ADDITION TO | | LOW VOLTAGE WIRING? PROVIDE CLARIFICATION. FBC 107.2.1 | | 3. PROVIDE DETAILS OF CONDUIT AND WIRE SIZE TO FIXTURES | | ON PLAN. FBC 107.2.1 | | 4. PROVIDE VOLTAGE DROP CALCULATIONS FOR EACH CIRCUIT | | IN COMPLIANCE WITH ENERGY CODE. FBC EC C405.6.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-06-29 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-06-29 |
Time |
15:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-09-24 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-09-21 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-09-20 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-09-20 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-08-21 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-07-11 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-07-11 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-06-11 |
Time |
11:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-05-23 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-05-23 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-04-18 |
Time |
08:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2018-09-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-09-05 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-25 |
Time |
10:09 |
Sent To |
|
|
Notes |
2018-09-05 07:41:47 | SHEET Y-401 IS DIGITALLY SIGNED BY A PERSON THAT | | APPEARS TO NOT BE LICENSED AS AN ENGINEER, NO TITLE | | BLOCK EXISTS FOR THIS PERSON ON PLAN. PROVIDE | | CORRECTION. FS 471.031 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-06-29 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-06-29 |
Time |
15:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2018-05-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-05-05 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-05-05 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-09-20 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2018-09-20 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-09-20 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2018-07-11 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2018-07-11 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-07-11 |
Time |
08:52 |
Sent To |
|
|
Notes |
2018-07-11 08:54:15 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 07.11.2018 | | PERMIT NO.: 18040797 | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. A PHOTOMETRIC PLAN SHALL BE PROVIDED. THE | | PHOTOMETRIC LEVELS SHALL NOT EXCEED 1.0 FOOTCANDLES | | WHEN MEASURED AT THE PROPERTY LINE AND SHALL NOT EXCEED | | 0.5 FOOTCANDLES WHEN MEASURED IN A RESIDENTIAL ZONING | | DISTRICT. - THE RESUBMITTAL RESPONSES INDICATED THAT | | THIS WAS SHOWN ON SHEET EP-200; HOWEVER, THERE IS NO | | SHEET EP-200 INCLUDED IN THE SUBMITTED DRAWINGS. PLEASE | | PROVIDE THE SHEET, OR OTHERWISE CLARIFY WHERE THE | | PHOTOMETRIC LEVELS CAN BE FOUND. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2018-05-22 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-05-22 |
Time |
17:14 |
Sent To |
|
|
Notes |
2018-05-22 17:14:15 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 05.22.2018 | | PERMIT NO.: 18040797 | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. A PHOTOMETRIC PLAN SHALL BE PROVIDED. THE | | PHOTOMETRIC LEVELS SHALL NOT EXCEED 1.0 FOOTCANDLES | | WHEN MEASURED AT THE PROPERTY LINE AND SHALL NOT EXCEED | | 0.5 FOOTCANDLES WHEN MEASURED IN A RESIDENTIAL ZONING | | DISTRICT. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|