Plan Review Details - Permit 18040406
Plan Review Stops For Permit 18040406 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-04-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-13 |
Time |
19:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-13 |
Time |
19:08 |
Sent To |
|
|
Notes |
2018-04-13 19:30:14 | | | | | | | | | ******REVIEW IN PROGRESS...... NOT FINAL YET | | | | | | | | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017). | | | | 1- ROOF TILE UNDERLAYMENT PROPOSED APPLICATION IS NOT | | CLEAR. ACCORDING TO POLYGLASS FLORIDA PRODUCT APPROVAL | | FL5259-R27 SUBMITTED THE CONCRETE TILE IS GOING TO BE | | FASTENED USING AH-160 ADHESIVE. UNDERLAYMENT SYSTEM #10 | | FROM SEC. 5.6.4 WAS HIGHLIGHTED. THE MAXIMUM DESIGN | | PRESSURE FOR #10 ASSEMBLY IS -45PSF. THIS ASSEMBLY | | DOESN'T MEET THE DESIGN PRESSURES FOR THE PERIMETER AND | | CORNER AREAS OF THIS HOUSE LOCATED IN EXPOSURE "C". IF | | USING THIS ASSEMBLY, THEN NEED TO PROVIDE SIGNED AND | | SEALED RAS 117 CALCULATIONS FOR PERIMETER AND CORNER | | AREAS AS REQUIRED BY HIGHLIGHTED SEC. 5.6.4.2 ON SAME | | FLORIDA PRODUCT APPROVAL. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DON?T STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-04-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-10 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-10 |
Time |
17:20 |
Sent To |
|
|
Notes |
2018-04-10 18:22:56 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017). | | | | 1- ROOF TILE UNDERLAYMENT PROPOSED APPLICATION IS NOT | | CLEAR. ACCORDING TO POLYGLASS FLORIDA PRODUCT APPROVAL | | FL5259-R27 SUBMITTED THE CONCRETE TILE IS GOING TO BE | | FASTENED USING AH-160 ADHESIVE. UNDERLAYMENT SYSTEM #10 | | FROM SEC. 5.6.4 WAS HIGHLIGHTED. THE MAXIMUM DESIGN | | PRESSURE FOR #10 ASSEMBLY IS -45PSF. THIS ASSEMBLY | | DOESN'T MEET THE DESIGN PRESSURES FOR THE PERIMETER AND | | CORNER AREAS OF THIS HOUSE LOCATED IN EXPOSURE "C". IF | | USING THIS ASSEMBLY, THEN NEED TO PROVIDE SIGNED AND | | SEALED RAS 117 CALCULATIONS FOR PERIMETER AND CORNER | | AREAS AS REQUIRED BY HIGHLIGHTED SEC. 5.6.4.2 ON SAME | | FLORIDA PRODUCT APPROVAL. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DON?T STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-04-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-13 |
Time |
19:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-12 |
Time |
11:45 |
Sent To |
I |
|
Notes |
2018-04-13 11:45:19 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-04-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-10 |
Time |
18:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-10 |
Time |
13:46 |
Sent To |
I |
|
Notes |
2018-04-10 13:46:54 | JGOMEZ |
|
|
|