|
 |
 |
 |
 |
 |
Plan Review Details - Permit 18040393
Plan Review Stops For Permit 18040393 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-05 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-06-05 |
Time |
11:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-04-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-04-23 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-04-23 |
Time |
13:15 |
Sent To |
E |
|
Notes |
2018-04-23 13:45:52 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE FIRST FLOOR DEMO PLAN. | | 2. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. | | 3. ELECTRICAL REVIEW REQUIRED. | | 4. SUBMITTAL HAS ONLY ONE COPY OF WINDOW PRODUCT | | APPROVAL. SUBMITTAL DOCUMENTS SHALL BE SUBMITTED IN | | DUPLICATE. | | NOTE: WELDER CERTIFICATIONS TO BE ON-SITE AT TIME OF | | INSPECTION. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW MULLION SUBMITTALS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-06-05 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-06-05 |
Time |
09:17 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-04-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-04-23 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-04-23 |
Time |
14:33 |
Sent To |
I |
|
Notes |
2018-04-23 14:38:29 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | 471.025; WPB FBC 107.2.1, 107.3.5 | | 2. PROVIDE FLOOR PLAN OF ENTIRE DWELLING UNIT SHOWING | | SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER CODE. | | SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE EXISTING | | OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC RE | | R314.3, R315.1; WPB FBC 107.2.1 | | 3. VALUE OF WORK STATED ON PLAN APPEARS LOW. PROVIDE | | COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE OF WORK, | | TO INCLUDE ALL MATERIALS AND LABOR. FBC 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-06-04 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-06-04 |
Time |
14:19 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2018-04-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-04-18 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-04-18 |
Time |
14:43 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-05 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-30 |
Time |
15:46 |
Sent To |
I |
|
Notes |
2018-05-31 15:46:17 | RESUB ROUTED TO HISTORIC INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-04-23 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-04-10 |
Time |
13:00 |
Sent To |
|
|
Notes |
2018-04-11 13:00:45 | ROUTED TO HISTORIC INBOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |