| 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 18031303 |
| ADD: 911 ALMERIA RD. |
| CONT: J & V RESIDENTIAL SERVICES |
| TEL: 561-601-1614 |
| E-MAIL: JVRESIDENTIAL [email protected] |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| 1ST REVIEW |
| DATE: FRI. MARCH 30, 2018 |
| ACTION: BUILDING PROVISO |
| 1) SLOPE 3 ? IN 12. PLEASE SHOW COMPLIANCE WITH 2017 |
| FBC-B TABLE 1507.1.1. |
| |
| 1. 1.ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS |
| HORIZONTAL (17-PERCENT SLOPE), AND LESS THAN FOUR UNITS |
| VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE). |
| APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT FELT |
| PARALLEL TO AND STARTING AT THE EAVES, FASTENED |
| SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, |
| APPLY 36-INCHWIDE (914 MM) SHEETS OF UNDERLAYMENT, |
| OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM), END |
| LAPS SHALL BE 6 INCHES AND SHALL BE OFFSET BY 6 FEET. |
| THE UNDERLAYMENT SHALL BE ATTACHED TO A NAILABLE DECK |
| WITH CORROSION-RESISTANT FASTENERS WITH ONE ROW |
| CENTERED IN THE FIELD OF THE SHEET WITH A MAXIMUM |
| FASTENER SPACING OF 12 INCHES (305 MM) O.C., AND ONE |
| ROW AT THE END AND SIDE LAPS FASTENED 6 INCHES (152 MM) |
| O.C. UNDERLAYMENT SHALL BE ATTACHED USING METAL OR |
| PLASTIC CAP NAILS WITH A NOMINAL CAP DIAMETER OF NOT |
| LESS THAN 1 INCH. METAL CAPS SHALL HAVE A THICKNESS OF |
| NOT LESS THAN 32-GAGE SHEET METAL. POWER-DRIVEN METAL |
| CAPS SHALL HAVE A MINIMUM THICKNESS OF 0.010 INCH. |
| MINIMUM THICKNESS OF THE OUTSIDE EDGE OF PLASTIC CAPS |
| SHALL BE 0.035 INCH. THE CAP NAIL SHANK SHALL BE NOT |
| LESS THAN 0.083 INCH FOR RING SHANK CAP NAILS AND 0.091 |
| INCH FOR SMOOTH SHANK CAP NAILS. CAP NAIL SHANK SHALL |
| HAVE A LENGTH SUFFICIENT TO PENETRATE THROUGH THE ROOF |
| SHEATHING OR NOT LESS THAN 3/4 INCH INTO THE ROOF |
| SHEATHING. |
| 2. 2.ROOF SLOPES OF FOUR UNITS VERTICAL IN 12 UNITS |
| HORIZONTAL (33-PERCENT SLOPE) OR GREATER. UNDERLAYMENT |
| SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO AND |
| STARTING FROM THE EAVE AND LAPPED 4 INCHES (51 MM), END |
| LAPS SHALL BE 6 INCHES AND SHALL BE OFFSET BY 6 FEET. |
| THE UNDERLAYMENT SHALL BE ATTACHED TO A NAILABLE DECK |
| WITH TWO STAGGERED ROWS IN THE FIELD OF THE SHEET WITH |
| A MAXIMUM FASTENER SPACING OF 12 INCHES (305 MM) O.C., |
| AND ONE ROW AT THE END AND SIDE LAPS FASTENED 6 INCHES |
| (152 MM) O.C. UNDERLAYMENT SHALL BE ATTACHED USING |
| METAL OR PLASTIC CAP NAILS WITH A NOMINAL CAP DIAMETER |
| OF NOT LESS THAN 1 INCH. METAL CAPS SHALL HAVE A |
| THICKNESS OF NOT LESS THAN 32-GAGE SHEET METAL. |
| POWER-DRIVEN METAL CAPS SHALL HAVE A MINIMUM THICKNESS |
| OF 0.010 INCH. MINIMUM THICKNESS OF THE OUTSIDE EDGE OF |
| PLASTIC CAPS SHALL BE 0.035 INCH. THE CAP NAIL SHANK |
| SHALL BE NOT LESS THAN 0.083 INCH FOR RING SHANK CAP |
| NAILS AND 0.091 INCH FOR SMOOTH SHANK CAP NAILS. CAP |
| NAIL SHANK SHALL HAVE A LENGTH SUFFICIENT TO PENETRATE |
| THROUGH THE ROOF SHEATHING OR NOT LESS THAN 3/4 INCH |
| INTO THE ROOF SHEATHING. |
| 3. 3.ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS |
| HORIZONTAL (17-PERCENT SLOPE), AND GREATER. THE ENTIRE |
| ROOF DECK SHALL BE COVERED WITH AN APPROVED |
| SELF-ADHERING POLYMER MODIFIED BITUMEN UNDERLAYMENT |
| COMPLYING WITH ASTM D1970 INSTALLED IN ACCORDANCE WITH |
| BOTH THE UNDERLAYMENT MANUFACTURER?S AND ROOF COVERING |
| MANUFACTURER?S INSTALLATION INSTRUCTIONS FOR THE DECK |
| MATERIAL, ROOF VENTILATION CONFIGURATION AND CLIMATE |
| EXPOSURE FOR THE ROOF COVERING TO BE INSTALLED. |
| EXCEPTION: A MINIMUM 4-INCH-WIDE (102 MM) STRIP OF |
| SELF-ADHERING POLYMER-MODIFIED BITUMEN MEMBRANE |
| COMPLYING WITH ASTM D1970, INSTALLED IN ACCORDANCE WITH |
| THE MANUFACTURER?S INSTRUCTIONS FOR THE DECK MATERIAL, |
| SHALL BE APPLIED OVER ALL JOINTS IN THE ROOF DECKING. |
| AN APPROVED UNDERLAYMENT IN ACCORDANCE WITH TABLE |
| 1507.1.1 FOR THE APPLICABLE ROOF COVERING SHALL BE |
| APPLIED OVER THE ENTIRE ROOF OVER THE 4-INCH-WIDE (102 |
| MM) MEMBRANE STRIPS. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER/ BUILDING |
| DIVISION / DEVELOPMENT SERVICES DEPART |
| |