Plan Review Details - Permit 18030964
Plan Review Stops For Permit 18030964
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-06-08 Cont ID  
Sent By cthroop Date 2018-06-08 Time 07:17 Rev Time 0.00
Received By cthroop Date 2018-06-08 Time 07:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-04-27 Cont ID  
Sent By cthroop Date 2018-04-27 Time 13:10 Rev Time 0.00
Received By cthroop Date 2018-04-27 Time 10:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-04-06 Cont ID  
Sent By cthroop Date 2018-04-06 Time 15:20 Rev Time 0.00
Received By cthroop Date 2018-04-06 Time 15:20 Sent To Z
Notes
2018-04-06 15:20:31BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGNER TO DEMONSTRATE THE 6 - 1/4" TOGGLE BOLTS
 ARE SUFFICIENT TO ATTACH A 13FT, 6 1/4" SIGN TO
 EXTERIOR CLADDING.
 2. IDENTIFY EXTERIOR CLADDING.
 3. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN.
 4. VALUE IS LOW FOR PROPOSED SCOPE OF WORK.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF
 WORK.
 THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
 CITY OF WPB CHPT. 1 ? VALUE
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2018-06-20 Cont ID  
Sent By jleahy Date 2018-06-20 Time 17:28 Rev Time 0.00
Received By jleahy Date 2018-06-20 Time 17:28 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2018-06-06 Cont ID  
Sent By jleahy Date 2018-06-06 Time 07:04 Rev Time 0.00
Received By jleahy Date 2018-06-06 Time 07:04 Sent To B
Notes
2018-06-06 07:08:34FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 600.6(A)(1) DISCONNECT ALL POWER BEFORE IT ENTERS THE
 SIGN. DISCOONECT IN SIGHT OF SIGN.
  
 600. 6 DISCONNECTS (A) LOCATION.
 (1) AT POINT OF ENTRY TO A SIGN ENCLOSURE. THE
 DISCONNECT
 SHALL BE LOCATED AT THE POINT THE FEEDER CIRCUIT OR
 BRANCH CIRCUIT(S)
 SUPPLYING A SIGN OR OUTLINE LIGHTING SYSTEM ENTERS A
 SIGN ENCLOSURE
 OR A POLE IN ACCORDANCE WITH 600.5(C)(3) AND SHALL
 DISCONNECT
 ALL WIRING WHERE IT ENTERS THE ENCLOSURE OF THE SIGN OR
 POLE
  
  
 VALUE FOR THE SIGN TO LOW FOR A SIGN THIS SIZE. CITY
 WILL ASSIGN A VALUE OF $5000 TO THE SIGN.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION
 REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF
 NATIONAL CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-
 SWIFT, MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE
 CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE
 SET BY THE BUILDING OFFICIAL
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-04-26 Cont ID  
Sent By jleahy Date 2018-04-26 Time 14:02 Rev Time 0.00
Received By jleahy Date 2018-04-26 Time 14:02 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-03-30 Cont ID  
Sent By cpuell Date 2018-04-10 Time 09:23 Rev Time 0.00
Received By jleahy Date 2018-03-30 Time 07:49 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-06-20 Cont ID  
Sent By jleahy Date 2018-06-20 Time 17:29 Rev Time 0.00
Received By jleahy Date 2018-06-13 Time 09:58 Sent To  
Notes
2018-06-14 09:58:48RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-06-08 Cont ID  
Sent By cthroop Date 2018-06-08 Time 07:17 Rev Time 0.00
Received By cthroop Date 2018-05-29 Time 16:01 Sent To I
Notes
2018-05-30 16:01:51RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-04-27 Cont ID  
Sent By cthroop Date 2018-04-27 Time 13:10 Rev Time 0.00
Received By cthroop Date 2018-04-19 Time 11:39 Sent To I
Notes
2018-04-20 11:40:05RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-04-10 Cont ID  
Sent By cpuell Date 2018-04-10 Time 09:23 Rev Time 0.00
Received By cpuell Date 2018-03-22 Time 12:47 Sent To E
Notes
2018-03-23 12:48:07ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 3 Status P Date 2018-05-31 Cont ID  
Sent By jroach Date 2018-05-31 Time 08:48 Rev Time 0.00
Received By jroach Date 2018-05-31 Time 08:48 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2018-04-25 Cont ID  
Sent By jroach Date 2018-04-25 Time 14:45 Rev Time 0.00
Received By jroach Date 2018-04-25 Time 14:45 Sent To E
Notes
2018-04-25 14:45:51ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 04.25.2018
 PERMIT NO.: 18030964
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PURSUANT TO THE HOME DEPOT COMMERICIAL PLANNED
 DEVELOPMENT (CPD) SIGN GUIDELINES (AS ADOPTED BY
 RESOLUTION NO. 101-17), SIGNS FOR TENANTS OF LESS THAN
 15,000 SQUARE FEET SHALL NOT EXCEED FOUR (4) FEET IN
 OVERALL HEIGHT.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-04-09 Cont ID  
Sent By jroach Date 2018-04-09 Time 16:02 Rev Time 0.00
Received By jroach Date 2018-04-09 Time 16:02 Sent To PC
Notes
2018-04-09 16:02:48ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 04.09.2018
 PERMIT NO.: 18030964
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PURSUANT TO THE HOME DEPOT COMMERICIAL PLANNED
 DEVELOPMENT (CPD) SIGN GUIDELINES (AS ADOPTED BY
 RESOLUTION NO. 101-17), SIGNS FOR TENANTS OF LESS THAN
 15,000 SQUARE FEET SHALL NOT EXCEED FOUR (4) FEET IN
 OVERALL HEIGHT.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  