Plan Review Details - Permit 18030644
Plan Review Stops For Permit 18030644 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-21 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-21 |
Time |
11:17 |
Sent To |
|
|
Notes |
2018-03-21 11:50:25 | BUILDING OK PENDING RESOLUTION OF ZONING COMMENTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-05-03 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-05-03 |
Time |
08:31 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-03-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-20 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-20 |
Time |
15:11 |
Sent To |
B |
|
Notes |
2018-03-20 15:11:16 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLEASE SEE ZONING COMMENTS. PLAN WILL NOT BE | | APPROVED WITH 2 METERS BASED ON ZONING REVIEW. ONLY ONE | | SERVICE PER RESIDENTIAL ADDRESS IS PERMITTED. PROVIDE | | CORRECTION. WPB FBC 107.2.1; NEC 230.2; FBC RE E3601.2 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-05-03 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-05-02 |
Time |
15:21 |
Sent To |
|
|
Notes |
2018-05-02 15:21:56 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-21 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-14 |
Time |
13:07 |
Sent To |
|
|
Notes |
2018-03-16 15:42:00 | RE-ROUTED TO ZONING FOR REVIEW PRIOR TO ELECTRICAL | | REVIEW. JP | | | | | 2018-03-16 13:07:26 | REVISION ROUTED TO JPEARSON |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-05-02 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-05-02 |
Time |
09:59 |
Sent To |
|
|
Notes |
2018-05-02 09:59:51 | OWNER PROVIDED AFIDAVIT THAT METER HAS BEEN THERE FOR | | 10+ YEARS AND ACCESSORY STRUCTURE WILL NOT BE USED AS A | | SECOND UNIT JUST FOR GUESTS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-03-19 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-03-19 |
Time |
16:10 |
Sent To |
E |
|
Notes |
2018-03-19 16:10:46 | LOT NOT LARGE ENOUGH TO PERMIT SECOND UNIT NOR DID IT | | HISTORICALLY HAVE ONE. SECOND METER NOT POSSIBLE. | 2018-03-16 15:41:12 | ZONING DEPARTMENT : CUSTOMER REQUESTED A CHANGE FROM | | ORIGINAL PLANS TO ADD A SECOND METER. PLEASE REVIEW. |
|
|
|
Account Summary | Usage Policy | Privacy Policy