Plan Review Details - Permit 18030227
Plan Review Stops For Permit 18030227
Review Stop G GAS REVIEW
Rev No 3 Status P Date 2018-05-25 Cont ID  
Sent By lcrespo Date 2018-05-25 Time 16:46 Rev Time 0.00
Received By lcrespo Date 2018-05-25 Time 16:46 Sent To  
Notes
2018-05-25 16:47:5805/24/18 APPROVED BY PLUMBING AND SENT TO PROCESSING,
 LAC

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2018-05-17 Cont ID  
Sent By lcrespo Date 2018-05-17 Time 16:08 Rev Time 0.00
Received By lcrespo Date 2018-05-17 Time 16:08 Sent To  
Notes
2018-05-17 16:08:2305/17/2018 1ST GAS REVIEW**DENIED** WITH COMMENTS NOTE
 - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME
 AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED
 UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. IT APPEARS THAT THERE ARE A GAS STOVE AND WATER
 HEATER PLEASE LIST THE BTU LOAD OF EACH APPLIANCE AND
 THE TOTAL BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC
 FUEL GAS RES. SEC. G2413.
 2. YOU ARE MISSING THE FIREPLACE IN THE BTU 7. INDICATE
 THE DELIVERY PRESSURE (PSI) OF THE SYSTEM ON THE PLAN
 PER 2014 FBC-FUEL GAS SEC.402.2 OR FBC RES. SEC.
 G2413.2.
 3. THE PLAN REVIEW INDICATES AN EXISTING GAS APPLIANCE.
 THE BTU LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED
 TO THE TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE
 EXISTING SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE
 EXISTING SYSTEM MUST BE REDONE TO ENSURE A SAFE
 OPERATING SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM
 THAT SHOWS THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD
 OF EACH APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO
 EACH APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH
 OF PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE
 OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE
 EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE
 SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE
 REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES
 2017 FBC FUEL GAS RES. SECS.G2412.4, G2412.8, G2413.1,
 G2413.2, G2413.3
 4. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION 2017 FBC FUEL
 GAS RES. SEC. G2413.2 AND G2404.3
 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 (CLOTHES DRYERS, GAS HEATER, AND STOVE) 2017 FBC FUEL
 GAS RES. SEC. G2407.1 AND G2439.4.
 6. INDICATE ON THE PLAN IF THE GRILL IS LOCATED UNDER A
 ROOF. WPB AMEND. TO FBC SEC. 107.2.1
 7. VALUE* JOB VALVE SEEM LOW, PROVIDED BONA FIDE SIGN
 CONTRACT. WPB AMEND TO THE FBC 109.3 BUILDING PERMIT
 VALUATIONS. IF IN THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF BUILDING, ALTERATION,
 STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR PLUMBING
 SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED UNLESS THE
 APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR
 BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO
 MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONA CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 [email protected]
 561-805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-03-09 Cont ID  
Sent By thunt Date 2018-03-09 Time 13:03 Rev Time 0.00
Received By thunt Date 2018-03-09 Time 13:03 Sent To  
Notes
2018-03-09 13:20:5203/09/2018 1ST GAS REVIEW**DENIED**
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
  
 THE MASTER PERMIT # 16110325 DOES NOT SHOW ANY GAS
 APPLIANCES.
  
  
 1) VALUE* JOB VALVE SEEM LOW, PROVIDED BONA FIDE SIGN
 CONTRACT. WPB AMEND TO THE FBC 109.3 BUILDING PERMIT
 VALUATIONS.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL
 BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
 2) PROVIDE REQUIRED MAKE UP AIR FOR ALL ROOMS THAT WILL
 HAVE A GAS APPLIANCES IN THEM. SUBMIT CALCULATIONS FOR
 COMBUSTION AIR PER THE 2014 FBC-FUEL GAS CODE
 SEC.304.1, 614.5 (CLOTHES DRYERS) OR 2014 FBC-RES. SEC.
 G 2407.1 AND G2439.4 (CLOTHES DRYERS). SUBMIT
 CALCULATIONS FOR COMBUSTION AIR PER THE 2014 FBC-FUEL
 GAS CODE SEC.304.1, 614.5 (CLOTHES DRYERS) OR 2014
 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES DRYERS). )
 SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS
 APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE
 BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM
 SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN
 ADDITION TO THE REQUIRED VENTILATION AIR. FGC
 SEC.304.9.3 OR FBCR G2407.9.3
  
 3) TYPE OF GAS (LP OR NATURAL). FBC 107.2.1
  
 4) YOU ARE MISSING THE FIRE PLACE IN THE BTU
 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM
 ON THE PLAN PER 2014 FBC-FUEL GAS SEC.402.2 OR FBC RES.
 SEC. G2413.2.
  
 5) INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM
 ON THE PLAN PER 2014 FBC-FUEL GAS SEC.402.2 OR FBC RES.
 SEC. G2413.2.
  
 6) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES
 USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE
 PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM
 THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE
 DESIGN OF THIS GAS SYSTEM. REFER TO THE 2014 FBC-FUEL
 GAS SECS. 401.4, 401.8 THRU 402.6.1 AND TABLES 402.4
 (1) THRU 402.4 (37) OR 2014 FBC-RES. SEC. G2412.4,
 G2412.8, G2413.1, G2413.2, & G2413.3.
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-05-25 Cont ID  
Sent By lcrespo Date 2018-05-25 Time 16:47 Rev Time 0.00
Received By lcrespo Date 2018-05-23 Time 13:23 Sent To  
Notes
2018-05-24 13:23:23RESUB ROUTED TO LCRESPO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-05-17 Cont ID  
Sent By lcrespo Date 2018-05-17 Time 16:08 Rev Time 0.00
Received By lcrespo Date 2018-05-17 Time 16:08 Sent To  
Notes
2018-05-09 10:45:05RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-09 Cont ID  
Sent By thunt Date 2018-03-09 Time 13:21 Rev Time 0.00
Received By thunt Date 2018-03-06 Time 12:58 Sent To I
Notes
2018-03-07 12:59:07PLUMB <5K