Plan Review Details - Permit 18030173
Plan Review Stops For Permit 18030173 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-30 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-30 |
Time |
10:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-21 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-21 |
Time |
14:59 |
Sent To |
|
|
Notes |
2018-03-21 15:12:34 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017). | | | | 1- DRAWINGS SUBMITTED ARE NOT ACCEPTABLE. NEED TO | | PROVIDE TWO COMPLETE SET OF DRAWINGS DRAWN TO SCALE AND | | CLEARLY SHOWING ALL THE SCOPE OF WORK S REQUIRED BY | | SEC. 107.2.1 CITY AMENDMENTS. | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | ELECTRONIC MEDIA DOCUMENTS SHALL BE | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL | | THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND | | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. | | SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE | | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL | | CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. (SEE ALSO SECTION 107.3.5). | | | | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. 908 FBC-EXISTING BUILDING. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. UPDATE AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS. | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION | | OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL | | CODE CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE | | SET BY THE BUILDING OFFICIAL. | | | | NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED MATERIALS | | MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DON?T STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-03-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-30 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-29 |
Time |
16:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-03-12 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-12 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-12 |
Time |
15:36 |
Sent To |
|
|
Notes |
2018-03-12 15:36:16 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED BY PERSON | | RESPONSIBLE FOR THE DESIGN. PER 107.2.1.4, QUALITY OF | | BUILDING PLANS. BUILDING PLANS SHALL BE DRAWN TO A | | MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL PAPER, CLOTH OR | | OTHER ACCEPTABLE MEDIUM. THIS POLICY MAY INCLUDE SUCH | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. FS 481.229; | | FBC 107.2.1, 107.3.5 | | 2. VALUE OF STATED WORK APPEARS LOW. PROVIDE COPY OF | | SIGNED CONTRACT WITH SCOPE AND VALUE OF WORK, TO | | INCLUDE ALL MATERIALS AND LABOR. FBC 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-30 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-29 |
Time |
15:40 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-21 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-05 |
Time |
13:22 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-21 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-21 |
Time |
16:02 |
Sent To |
|
|
Notes |
2018-03-21 16:04:23 | NO WORK SHOWN FOR MECHANICAL WORK. | | | | PROVIDE COMPLETE INFORMATION FOR ANY MECHANICAL WORK . |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2018-03-29 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-03-29 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-03-29 |
Time |
15:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-21 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-21 |
Time |
16:03 |
Sent To |
|
|
Notes |
2018-03-21 16:03:13 | RESIDENTIAL (R3) ALTERATION, PLUMBING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017). | | | | 1- DRAWINGS SUBMITTED ARE NOT ACCEPTABLE. NEED TO | | PROVIDE TWO COMPLETE SET OF DRAWINGS DRAWN TO SCALE AND | | CLEARLY SHOWING ALL THE SCOPE OF WORK S REQUIRED BY | | SEC. 107.2.1 CITY AMENDMENTS. | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | ELECTRONIC MEDIA DOCUMENTS SHALL BE | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL | | THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND | | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. | | SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE | | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL | | CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. (SEE ALSO SECTION 107.3.5). | | | | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. 908 FBC-EXISTING BUILDING. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. UPDATE AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS. | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION | | OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL | | CODE CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE | | SET BY THE BUILDING OFFICIAL. | | | | NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED MATERIALS | | MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DON?T STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
|